background image

Switching between channels

11

 · G&D DP1.2-MUX2-NT

Switching via step keys

Alternative to using 

select keys

 to switch between channels connected to the KVM 

switch is to use the 

step keys

 to switch the channels in ascending or descending order.

How to use select keys to switch to a particular channel:

1. Press 

»Forward« Step key 

or 

»Back« Step key 

on the console keyboard.

IMPORTANT: 

The active 

step keys

 depend on the selected 

select keys

. The following 

table lists the step keys depending on the active select keys.

Select keys

»Back« Step key 

»Forward« Step key 

1 … 2

9

0

NUM 1 … NUM 2

NUM 9

NUM 0

A … B

I

K

F1 … F2

F9

F10

Summary of Contents for DP1.2-MUX2-NT

Page 1: ...Guntermann Drunck GmbH www gdsys de G D DP1 2 MUX2 NT A9100322 1 00 Installation und Bedienung DE EN Installation and Operation ...

Page 2: ... G D übernimmt keine Gewährleistung für Geräte die nicht bestimmungsgemäß eingesetzt wurden nicht autorisiert repariert oder modifiziert wurden schwere äußere Beschädigungen aufweisen welche nicht bei Lieferungserhalt angezeigt wurden durch Fremdzubehör beschädigt wurden G D haftet nicht für Folgeschäden jeglicher Art die möglicherweise durch den Einsatz der Produkte entstehen können Warenzeichenn...

Page 3: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interfer ence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter mined by turning th...

Page 4: ...analumschaltung 12 Umschaltung über ein serielles Gerät 12 Umschaltung über die Webapplikation 13 Umschaltung über das Umschalt Tool 13 Umschaltung via SNMP 13 Verwendung des Reset Tasters 14 Wiederherstellung der Standardeinstellungen 14 Temporäre Deaktivierung der Netzfilterregeln 15 Erstkonfiguration der Netzwerkeinstellungen 16 Verbindung der Netzwerkschnittstelle 16 Start der Webapplikation 1...

Page 5: ...Befehle in einem XML Dokument kombinieren 24 Push Notifications bei Kanalwechseln 24 Push Notifications abbestellen 25 Push Notifications abonnieren 25 Konfiguration 25 Zugänge des Gerätes für XML Steuerung konfigurieren 25 Befehle 26 Aufschaltung eines bestimmten Kanals 26 Trennung eines Kanals 26 Aufschaltung des nächsten Kanals 26 Aufschaltung des vorherigen Kanals 27 Monitoring Werte abfragen ...

Page 6: ...und alle Spannungsversorgungen am Gerät ab Ständigen Zugang zu den Netzsteckern der Geräte sicherstellen Achten Sie bei der Installation der Geräte darauf dass die Netzstecker der Geräte jederzeit zugänglich bleiben Lüftungsöffnungen nicht verdecken Bei Gerätevarianten mit Lüftungsöffnungen ist eine Verdeckung der Lüftungs öffnungen unbedingt zu vermeiden Korrekte Einbaulage bei Geräten mit Lüftun...

Page 7: ...auchte Batterien dürfen nicht in den Hausmüll geworfen werden Beachten Sie die gültigen Vorschriften zur Entsorgung elektronischer Produkte CAUTION Risk of explosion if the battery is replaced by an incorrect battery type Dispose of used batteries in an environmentally friendly manner Do not dispose of batteries in municipal waste Check local regulations for the disposal of electronic products ATT...

Page 8: ...ng oder via SNMP An der Frontseite des Geräts stehen zwei USB 3 0 Schnittstellen zum Betrieb belie biger USB Geräte zur Verfügung Die angeschlossenen USB Geräte werden dem jeweils aktiven Rechner zur Verfügung gestellt Lieferumfang 1 KVM Switch DP1 2 MUX2 NT 1 Datenkabel USB Service 2 1 Stromversorgungskabel 1 Rackmount Set 1 Handbuch Installations und Bedienungsanleitung 1 Handbuch Webapplikation...

Page 9: ...uf Seite 8 an der Frontseite platziert Rückseite des KVM Switches Auf der Rückseite des KVM Switches sind die Schnittstellen zum Anschluss der Geräte des Arbeitsplatzes und der Rechner angeordnet Eine detaillierte Beschrei bung der Schnittstellen finden Sie auf den folgenden Seiten Aufstellen des Geräts 1 Stellen Sie sicher dass die an den KVM Switch anzuschließenden Rechner aus geschaltet sind Fa...

Page 10: ...eschlossenen Rechnern USB Geräte zur Verfügung stellen schließen Sie diese Geräte an diese Schnittstellen an der Frontseite an Abbildung 2 Schnittstellen zum Anschluss der Geräte des Arbeitsplatzes HINWEIS Die Maus sowie die Tastatur des Arbeitsplatzes können Sie wahlweise als PS 2 an die Schnittstelle PS 2 K M oder als USB Gerät an die Schnittstellen USB K M anschließen HINWEIS Bei Geräten einer ...

Page 11: ...ür ein USB 3 0 Anschlusskabel DP CPU Verbinden Sie den Videoausgang des Rechners mit dieser Schnittstelle Ver wenden Sie hierfür ein DisplayPort Kabel HINWEIS Zum Anschluss der maximal zwei Rechner an den KVM Switch sind die unten aufgeführten Schnittstellen für jeden Rechner verfügbar Die DisplayPort Schnittstellen sind am oberen Rand angeordnet Die übrigen Schnittstellen sind blockweise am unter...

Page 12: ... höher ein Verbinden Sie das andere Ende des Kabels mit einem lokalen Netzwerk Anschluss der Stromversorgung Main Power Verbinden Sie ein Kaltgeräte Kabel mit einer Netzsteckdose und dieser Buchse Red Power Verbinden Sie falls gewünscht ein weiteres Kaltgeräte Kabel mit einer Netzsteckdose und dieser Buchse Hierdurch wird eine zweite redundante Stromversorgung des Gerätes erreicht Abbildung 4 Schn...

Page 13: ...aus Das redundante Netzteil ist ausgeschaltet oder die Verbindung mit dem Stromnetz nicht hergestellt Main an Das Hauptnetzteil ist eingeschaltet und liefert die erforderliche Spannung aus Das Hauptnetzteil ist ausgeschaltet oder die Verbindung mit dem Stromnetz nicht hergestellt Status Ready an Das Gerät ist betriebsbereit aus Das Gerät befindet sich in der Initialisierungsphase oder ist ausgesch...

Page 14: ...2 Active an Der Kanal ist aufgeschaltet aus Der Kanal ist derzeit nicht aufgeschaltet Status an Der angeschlossener Rechner ist eingeschaltet aus Es ist kein Rechner angeschlossen oder der Rechner ist ausgeschaltet Bereich LED Status Bedeutung ...

Page 15: ...en Sie auf der Tastatur des Arbeitsplatzes die Tastenkombination Strg Select Key Im Auslieferungszustand ist die Umschaltung des Kanals über den Modifizierer Strg und die Select Keys 1 bis 2 möglich TIPP Die erweiterten Möglichkeiten zur Kanalumschaltung über ein serielles Gerät über die Webapplikation Config Panel über das Umschalt Tool EasyControl über die XML Steuerung oder via SNMP werden im f...

Page 16: ...p Keys umschalten So schalten Sie mit Step Keys auf einen bestimmten Kanal um 1 Betätigen Sie auf der Tastatur des Arbeitsplatzes die Tastenkombination Hotkey Step Key vor oder Hotkey Step Key zurück WICHTIG Die jeweils aktiven Step Keys sind von der Auswahl der Select Keys abhän gig Die folgende Tabelle listet die Step Keys in Abhängigkeit von den aktiven Select Keys auf Select Keys Step Key zurü...

Page 17: ...nd die nachfolgend aufgeführten Anschlusseinstellungen durch das serielle Endgerät anzuwenden Bits pro Sekunde 9 600 Datenbits 8 Parität keine Stoppbits 1 Flussteuerung keine Zur Umschaltung des Kanals stehen die folgenden Befehle zur Verfügung WICHTIG Voraussetzungen für die erfolgreiche Schaltung des Kanals durch ein serielles Endgerät sind u a die Anwendung der unten aufgeführten Anschlussein s...

Page 18: ...ienung des Webapplikation Umschaltung über das Umschalt Tool Die Umschaltung auf einen der am KVM Switch angeschlossenen Rechner kann über das Umschalt Tool EasyControl durchgeführt werden Detaillierte Informationen hierzu finden Sie ebenfalls im separaten Handbuch zur Bedienung des Webapplikation Umschaltung via SNMP So schalten Sie die Signalübertragung via SNMP um Setzen Sie das Managed Object ...

Page 19: ...ngen wieder her 1 Schalten Sie das Gerät aus falls dieses derzeit in Betrieb ist 2 Betätigen Sie den Reset Taster an der Frontseite des Gerätes und halten Sie diesen gedrückt 3 Halten Sie den Taster weiterhin gedrückt und schalten Sie das Gerät ein 4 Sobald die grüne System LED schnell blinkt lassen Sie die Taste los HINWEIS Um die versehentliche Betätigung des Tasters zu vermeiden ist dieser hint...

Page 20: ...n Verhindern die aktuell eingestellten Netzfilterregeln den Zugang auf die Webappli kation können Sie die Netzfilterregeln temporär deaktivieren um diese anschlie ßend zu editieren So deaktivieren Sie die eingerichteten Netzfilterregeln temporär 1 Betätigen Sie den Reset Taster auf der Frontseite des Gerätes und halten Sie die sen 5 Sekunden gedrückt 2 Bearbeiten Sie die im Gerät gespeicherten Net...

Page 21: ... Gerätes angehört 3 Schalten Sie den KVM Switch ein Start der Webapplikation So konfigurieren Sie die Einstellungen einer Netzwerkschnittstelle 1 Starten Sie den Webbrowser des Rechners und geben Sie in der Adresszeile die URL 192 168 0 1 ein 2 Geben Sie in die Login Maske folgende Daten ein HINWEIS Im Auslieferungszustand sind folgende Einstellungen vorausgewählt IP Adresse der Netzwerkschnittste...

Page 22: ...cal Adressraum 169 254 0 0 16 ist gemäß RFC 3330 für die interne Kommunikation zwischen Geräten reserviert Die Zuordnung einer IP Adresse dieses Adressraums ist nicht möglich Betriebsmodus Wählen Sie den Betriebsmodus der Schnittstelle A bzw Schnittstelle B aus Aus Netzwerkschnittstelle ausschalten Statisch Es wird eine statische IP Adresse zugeteilt DHCP Bezug der IP Adresse von einem DHCP Server...

Page 23: ... lokale Netzwerk an 1 Entfernen Sie die Twisted Pair Kabelverbindung zwischen dem Rechner und dem Gerät 2 Integrieren Sie das Gerät in das lokale Netzwerk Betriebsmodus Wählen Sie den gewünschten Betriebsmodus Statisch Verwendung von statischen Einstellungen DHCP Bezug der Einstellungen von einem DHCP Server Host Name Geben Sie den Host Namen des Gerätes ein Domäne Geben Sie die Domäne an welcher ...

Page 24: ...erte Netzwerkfunktionen Netzfilter Syslog Backup und Restore Funktion Bedienung der Webapplikation Die Bedienung der Webapplikation wird im separaten Handbuch über die Webapplikation Config Panel der MUX NT Serie beschrieben Das Handbuch finden Sie im Lieferumfang des KVM Switches WICHTIG Grundlegende Voraussetzung für den Zugriff auf die Webapplikation des KVM Switches ist die Konfiguration der N...

Page 25: ...cht verwendet 2 RxD Receive Data 3 TxD Transmit Data 4 nicht verwendet 5 GND Ground 6 nicht verwendet 7 RTS Request to Send 8 CTS Clear to Send 9 5V DC max 100 mA Hinweise unten beachten WICHTIG Beachten Sie folgende Empfehlungen bei der Verkabelung des KVM Switches mit dem seriellen Endgerät um Beschädigungen an den Geräten zu ver meiden Lassen Sie ungenutzte Pins bei der Verkabelung des KVM Swit...

Page 26: ...mschaltung des aktiven Kanals durch den Anwender steht das USB Gerät dem bisher aktiven Rechner sofort nicht mehr zur Verfügung Falls der Rech ner zu diesem Zeitpunkt Daten auf das Massenspeichergerät schreibt wird dieser Vorgang abgebrochen Um einen Datenverlust zu vermeiden verwenden Sie die Funktion zum sicheren Entfer nen der Hardware des auf dem Rechner eingesetzten Betriebssystems vor der Um...

Page 27: ...ert Auswahl der Geräte Die XML API bietet durchgängig die Möglichkeit Geräte über ihre ID oder ihren Namen anzugeben Über das Attribut type können Sie zwischen der Auswahl per ID id oder per Namen name unterscheiden Das Attribut wird von allen Befehlen unterstützt die sich auf Geräte beziehen die einen Namen besitzen AUFBAU EINES GÜLTIGEN XML DOKUMENTS xml version 1 0 encoding utf 8 optionaler Hea...

Page 28: ...L Dokument Antworten des Gerätes Die Antworten des Geräts werden durch ein result Tag umschlossen Im Attribut type ist der Name des ausgeführten Befehls enthalten Beim Ausführen mehrerer Befehle in einem XML Dokument siehe unten können Sie so die Antwor ten den verschiedenen Befehlen zuordnen Meldungen des Geräts Kann der XML Dienst eine Anfrage nicht interpretieren antwortet der Dienst mit einem ...

Page 29: ...ML Dokument stehen vom XML Dienst abgearbeitet Die korrespondierende Antwort fasst die Antworten der einzelnen Befehle in einem Dokument zusammen Push Notifications bei Kanalwechseln Bei TCP Verbindungen sendet der Dienst der textbasierten Steuerung Push Notificati ons um über einen Kanalwechsel zu informieren Solche Ereignisse werden in einem pushNotification Container gemeldet Der Typ der Benach...

Page 30: ...Konfiguration 3 Klicken Sie auf den Reiter Netzwerk 4 Wählen Sie den Bereich Remote Control 5 Klicken Sie zur Einrichtung eines neuen Zugangs auf Hinzufügen Um einen bereits angelegten Zugang zu editieren klicken Sie auf Bearbeiten HINWEIS Die Abbestellung gilt nur für die Verbindung über welche der unsubs cribe Kommando gesendet wurde BENACHRICHTIGUNGEN FÜR KANALWECHSEL DEAKTIVIEREN xml version 1...

Page 31: ...ten Kanals Der Befehl nextmuxchannel schaltet den nächsten Kanal des KVM Switches auf Zugang Wählen Sie das Protokoll TCP oder UPD über welches die XML Kommunikation abgewickelt wird Port Geben Sie den Port an über welchen die XML Kommuni kation abgewickelt wird Die Ports 80 443 und 27996 werden für andere Dienste ver wendet Sie sind für die XML Steuerung nicht verfügbar Status Wählen Sie ob der Z...

Page 32: ...es angegeben werden Hierzu ein Beispiel Durch die Angabe des gewünschten Monitoring Wertes können Sie die Auflistung zusätzlich eingeschränken AUFSCHALTUNG DES VORHERIGEN KANALS xml version 1 0 encoding utf 8 root prevmuxchannel root ALLE MONITORING WERTE ALLER KVM SWITCHES ABFRAGEN xml version 1 0 encoding utf 8 root monitor DlMux4 monitor root ALLE MONITORING WERTE DES KVM SWITCHES 0X11111111 AB...

Page 33: ... type monitor DlMux4 item id 0x11111111 id name MUX ATC name monitorName Status monitorName value 1 value alarm off alarm acknowledged no acknowledged item DlMux4 result root HINWEIS Neben dem Namen und Wert des jeweiligen Monitoring Wertes wer den immer auch die beiden Flags acknowledged und alarm zurückgegeben Anhand der alarmFlags können Sie feststellen ob sich der Monitoring Wert im Sollbereic...

Page 34: ... mm Klinkenbuchse Speaker externer Umschalter 1 RS232 Buchse Rechner Anschlüsse pro Gerät 2 Anschluss mit optionalen Kabelsets am Gerät Schnittstellen pro Rechner Video siehe Eigenschaften der Varianten PS 2 1 PS 2 Buchse Adapter für zusätzliche Ausführung der PS 2 Buchse verfügbar USB 1 USB B Buchse USB 3 0 1 USB B Buchse Audio 1 3 5 mm Klinkenbuchse Line In Weitere Schnittstellen Netzwerk 2 RJ45...

Page 35: ...orbereitet um Monitore mit DDC CI Funktion zu unterstützen Die DDC Informationen werden dabei trans parent an den Monitor weitergeleitet um eine größtmögliche Anzahl an Monitoren zu unterstützen Die Unterstützung kann jedoch nicht für alle Monitor Modelle garantiert werden USB Spezifikation USB 3 1 Gen 1 USB 3 0 USB 2 0 kompatibel Übertragungsrate SuperSpeed 5 0 Gbps Low Speed Full Speed Hi Speed ...

Page 36: ...se Stromversorgung Stromaufnahme 0 3 A 240VAC 0 5 mA 100VAC Gehäuse Material Aluminium eloxiert Maße B H T 435 44 210 mm Gewicht ca 2 4 kg DP1 2 MUX2 NT MC2 Anzahl Videoquellen pro Rechner Arbeitsplatz 2 Schnittstellen für Arbeitsplatz Video 2 DisplayPort Buchse Schnittstellen pro Rechner Video 2 DisplayPort Buchse Stromversorgung Stromaufnahme 0 4 A 240VAC 0 6 mA 100VAC Gehäuse Material Aluminium...

Page 37: ... Deutsch ...

Page 38: ...l not provide warranty for devices that Are not used as intended Are repaired or modified by unauthorized personnel Show severe external damages that was not reported on the receipt of goods Have been damaged by non G D accessories G D will not be liable for any consequential damages that could occur from using the products Proof of trademark All product and company names mentioned in this manual ...

Page 39: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interfer ence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be deter mined by turning th...

Page 40: ... between channels 12 Switching via serial device 12 Switching via web application 13 Switching via switching tool 13 Switching via SNMP 13 Use of the Reset button 14 Restoring the default settings 14 Temporarily disabling the network filter rules 15 Initial configuration of the network settings 16 Establishing a connection to the network interface 16 Starting the web application 16 Configuring the...

Page 41: ...e commands in an XML document 24 Push notifications for switching between channels 24 Unsubscribing from push notifications 25 Subscribing to push notifications 25 Configuration 25 Configuring the device s accesses for XML control 25 Commands 26 Switching to a particular channel 26 Disconnecting from a channel 26 Switching to the next channel 26 Switching to the previous channel 27 Querying monito...

Page 42: ...ice has been disconnected from all power sources Disconnect all power plugs and all power supplies of the device Ensure constant access to the power plugs During the installation of the devices ensure that the power plugs remain accessible Do not cover the ventilation openings Ventilation openings prevent the device from overheating Do not cover them Ensure proper installation position For reasons...

Page 43: ...t dispose of batteries in municipal waste Check local regulations for the disposal of electronic products ATTENTION Il y a danger d explosion s il y a remplacement incorrect de la batterie Mettre au rebut les batteries usagées conformêment aux instructions du fabricant et de manière écologique Les batteries usagées ne doivent pas être jetées dans les ordures ménagères Respectez les prescriptions v...

Page 44: ... Two USB 3 0 interfaces are available on the front of the device for operating any USB device The connected USB devices are available at the active computer Scope of delivery 1 KVM switch DP1 2 MUX2 NT 1 data cable USB Service 2 1 power cable 1 rack mount set 1 manual Installation and Operation Guide 1 manual Web application Config Panel NOTE You can connect computers with up to two video outputs ...

Page 45: ...veral LEDs see Status displays on page 8 Back panel of the KVM switch The interfaces for connecting the workstation devices and the computers are located on the back panel of the KVM switch You can find a detailed description of the interfaces on the following pages Setting up the device 1 Make sure that the computers you want to connect to the KVM switch are turned off If the computers are equipp...

Page 46: ...If you want to make USB devices available to the connected computers connect these devices to these interfaces on the front panel Figure 2 Interfaces for connecting the workstation devices NOTE If mouse and keyboard of the workstation are PS 2 devices connect them to the PS 2 K M interface If they are USB devices connect them to the USB K M interfaces NOTE For multichannel devices the interfaces D...

Page 47: ...uter s USB 3 0 interfaces to this interface DP CPU Use the DisplayPort cable to connect the computer s video output to this interface NOTE To connect the up to two computers to the KVM switch the interfaces listed below are available for each computer The DisplayPort interfaces are placed at the top The other interfaces are arranged in blocks at the bottom edge Figure 3 Interfaces for connecting t...

Page 48: ...available as an accessory Connect the other end of the cable to a local network Connecting the power supply Main Power Connect a power cable to a mains socket and this socket Red power If desired connect another power cable to a mains socket and this socket This provides the device with a second redundant power supply Figure 4 Interface for connecting the power supply Figure 5 Interface for connec...

Page 49: ...redundant power supply is switched off or the connection to the power supply is not established Main On The main power supply is switched on and supplies the required voltage Off The main power supply is switched off or the connection to the power supply is not established Status Ready On The device is ready for operation Off The device is being initialised or is switched off System On Software ha...

Page 50: ... Flashing The devices connected to the USB 3 0 Devices inter face are permanently switched to this channel pin ning Off Inactive channel Status On The connected computer is switched on Off No computer is connected or the computer is switched off Area LED Status Meaning ...

Page 51: ...ns to switch to a particular channel Press the key combination Ctrl Select key on the keyboard of the workstation By default you can use the modifier Ctrl and the select keys 1 to 2 to switch between channels ADVICE Advanced ways to switch between channels via a serial device the web application Config Panel the switching tool EasyControl XML control or SNMP are described in the following chapter ...

Page 52: ... in ascending or descending order How to use select keys to switch to a particular channel 1 Press Hotkey Forward Step key or Hotkey Back Step key on the console keyboard IMPORTANT The active step keys depend on the selected select keys The following table lists the step keys depending on the active select keys Select keys Back Step key Forward Step key 1 2 9 0 NUM 1 NUM 2 NUM 9 NUM 0 A B I K F1 F...

Page 53: ... to the KVM switch the serial device must use the connection settings listed below Bits per second 9 600 Data bits 8 Parity none Stop bits 1 Flow control none The following commands are available for switching between channels IMPORTANT If you want to use a serial device to switch between channels you need to apply the connection settings listed below and use the switching com mands provided for t...

Page 54: ... application Switching via switching tool Switching to one of the computers connected to the KVM switch can be carried out via the switching tool EasyControl Detailed information on this topic are given in the separate manual for operating the web application Switching via SNMP How to switch the signal transmission via SNMP Use the SNMP management station to set the managed object selectedChannel ...

Page 55: ...tings of the KVM switch How to restore the system defaults 1 Switch the device off if it is in use 2 Press and hold the Reset button on the front panel of the device 3 Keep the button pressed and switch the device on 4 Release the button as soon as the green System LED starts blinking fast NOTE To avoid pressing the button by accident it is placed behind a hole in the front panel Use a thin pointe...

Page 56: ...mpared with the network filter rules If the currently defined network filter rules prevent access to the web application you can temporarily disable the network filter rules and then edit them How to temporarily disable network filter rules 1 Press and hold the Reset button on the front panel of the device for five seconds 2 Use the web application Config Panel to edit the network filter rules sto...

Page 57: ...the subnet to which the IP address of the device belongs 3 Turn on the KVM switch Starting the web application How to configure the settings of a network interface 1 Start the computer s web browser and enter the URL 192 168 0 1 in the address line 2 Enter the following data in the login mask NOTE By default the following settings are preselected IP address of Network interface A 192 168 0 1 IP ad...

Page 58: ...ocal address space 169 254 0 0 0 16 is reserved for internal com munication between devices according to RFC 3330 It is not possible to assign an IP address of this address space Operating mode Select the operating mode of Interface A or Interface B Off Switch off network interface Static A static IP address is assigned DHCP Obtain IP address from a DHCP server IP address Only if the Static operat...

Page 59: ...M switch to the local network 1 Remove the twisted pair cabling between computer and device 2 Integrate the device into the local network Operating mode Enter the desired operating mode Static Use of static settings DHCP Obtain settings from a DHCP server Hostname Enter the hostname of the device Domain Enter the domain to which the device should belong Gateway Enter the IP address of the gateway ...

Page 60: ...netfilter syslog Backup and restore function Operating the web application Instructions on how to operate the web application are given in the separate manual of the web application Config Panel of the MUX NT series The manual is included in the package contents of the KVM switch IMPORTANT The basic requirement for accessing the web application of the KVM switch is the configuration of the device ...

Page 61: ...duit 1 not occupied 2 RxD Receive Data 3 TxD Transmit Data 4 not occupied 5 GND Ground 6 not occupied 7 RTS Request to Send 8 CTS Clear to Send 9 5V DC max 100 mA necessarily see advices below IMPORTANT Please mind the following recommendations when connecting the KVM switch to serial device to avoid damages at the devices Unused contacts should be left unconnected when connecting the KVM switch t...

Page 62: ...f the KVM switch If the active channel is switched by the user the USB device is no longer provided to the so far active computer In case the computer writes data on the mass storage device at that time this process is aborted Before switching the channel use the Safely remove hardware function of the applied operating system of the computer to avoid data loss ...

Page 63: ...oot The commands are described on page 26 Selecting devices The XML API provides the ability to specify devices by their ID or name Use the attribute type to select devices via ID id or via name name The attribute is supported by all commands referring to named devices STRUCTURE OF A VALID XML DOCUMENT xml version 1 0 encoding utf 8 optional header root start tag of the document root end tag of th...

Page 64: ...es of the device Responses of the device are included in a result tag The attribute type includes the name of the executed command When executing several commands within the same XML document see below you can assign the responses to the different commands Messages of the device If the XML service is not able to process a request the service responds with an error document Depending on the type of...

Page 65: ...e listed in the XML docu ment The corresponding answer summarises the answers of the individual commands in a document Push notifications for switching between channels For TCP connections the service for text based control sends push notifications to inform users about the switching of a channel Such events are reported in a pushNotification container The type of notification is listed as type at...

Page 66: ... configure and then click on Configuration 3 Click on the tab Network 4 Go to Remote control 5 To create a new access click on Add To edit an existing access click on Edit NOTE The cancellation applies only for the connection on which the unsubscribe command is sent DISABLING NOTIFICATIONS FOR SWITCHING BETWEEN CHANNELS xml version 1 0 encoding utf 8 root unsubscribe Notification type channel_sele...

Page 67: ...ch Switching to the next channel Use the command nextmuxchannel to switch to the next channel of the KVM switch Access Select the protocol TCP or UPD to be used to process com munication via XML Port Enter the port to process XML communication Ports 80 443 und 27996 are used for other services They are not available for XML control Status Define whether the configured access should be enabled or d...

Page 68: ...ring value can be stated Example You can further restrict the list by specifying the desired monitoring value SWITCHING TO THE PREVIOUS CHANNEL xml version 1 0 encoding utf 8 root prevmuxchannel root QUERYING ALL MONITORING VALUES OF ALL KVM SWITCHES xml version 1 0 encoding utf 8 root monitor DlMux4 monitor root QUERYING ALL MONITORING VALUES OF THE KVM SWITCH 0X11111111 xml version 1 0 encoding ...

Page 69: ...DlMux4 item id 0x11111111 id name MUX ATC name monitorName Status monitorName value 1 value alarm off alarm acknowledged no acknowledged item DlMux4 result root NOTE In addition to the name and value of the respective monitoring value the two flags acknowledged and alarm are also always returned You can use the alarm flags to determine whether the monitoring value is within off or outside on the r...

Page 70: ...ack plug speakers External switch 1 RS232 socket Computer Connectors per device 2 Connection With optional cable sets on the device Interfaces per computer Video See variant features PS 2 1 PS 2 socket Adapter for additional PS 2 interface available USB 1 USB B socket USB 3 0 1 USB B socket Audio 1 3 5 mm jack plug line in Other interfaces Network 2 RJ45 socket Service 1 Mini USB B socket Audio Di...

Page 71: ...port via DP AUX channel DDC CI The device is ready to support monitors with a DDC CI function The DDC informa tion are transparently forwarded to the monitor to support a maximum number of monitors However the support cannot be guaranteed for all monitor models USB Specification USB 3 1 Gen 1 USB 3 0 USB 2 0 compatible Transmission rate SuperSpeed 5 0 Gbps low speed full speed hi speed compatible ...

Page 72: ...wer consumption 0 3 A 240VAC 0 5 mA 100VAC Housing Material Anodised aluminium Dimensions W H D 435 44 210 mm Weight Approx 2 4 kg DP1 2 MUX2 NT MC2 Number of video sources Per computer workstation 2 Interfaces for workstation Video 2 DisplayPort socket Interfaces per computer Video 2 DisplayPort socket Power supply Power consumption 0 4 A 240VAC 0 6 mA 100VAC Housing Material Anodised aluminium D...

Page 73: ... English ...

Page 74: ... ...

Page 75: ... English ...

Page 76: ...ere Leimbach 9 57074 Siegen Germany http www gdsys de sales gdsys de Das Handbuch wird fortlaufend aktualisiert und im Internet veröffentlicht The manual is constantly updated and available on our website http gdsys de A9100322 ...

Reviews: