background image

Configuration

25

 · G&D DL-DVI-Vision-Fiber

Configuration settings

Changing hotkeys

If many applications that use hotkeys are operated on one computer or if different 

KVM devices are used in one cascade, the number of available hotkeys might be 

restricted.

In case an application or another device used within the cascade use the same hot-

key, the hotkey can be changed.

How to change the current hotkey:

NOTE: 

Select your desired key or key combination from the keys 

Ctrl

Alt

Alt Gr

Win

 or 

Shift

.

OSD

1. Press 

Ctrl+Num

 (default) to open the on-screen display.

2. Select the row 

System setup

 and press 

Enter

.

3. Select the row 

Hotkey

 and press 

Enter

.

4. Under 

Modifier

, select 

at least

 one of the listed hotkey modifiers by selecting 

the box with the arrow keys. Press 

F8

 to confirm your selection:

Ctrl

Ctrl

 key (

default

)

Alt

Alt

 key

Alt Gr 

Alt Gr

 key

Win

Windows

 key

Shift

Shift

 key

5. Press 

F2

 to save your settings.

Conf

ig

 Pan

el

1. In the menu, click on 

KVM extender

.

2. Click on the computer module (CPU) you want to configure and then click

 

on

 Configuration

.

3. Click on the tab 

General

 and then on the tab 

CPU

.

4. In the 

Hotkey modifier

 field of the 

Configuration

 section, select 

at least

 one of the 

listed modifier keys (

Ctrl

Alt

Alt Gr

Win

 or 

Shift

) by marking the corre-

sponding check box.

5. Click on 

Save

.

Summary of Contents for DL-DVI-Vision-Fiber Series

Page 1: ...Guntermann Drunck GmbH www gdsys de G D DL DVI Vision Fiber A9100319 1 11 Installation und Bedienung DE EN Installation and Operating Guide...

Page 2: ...uss G D bernimmt keine Gew hrleistung f r Ger te die nicht bestimmungsgem eingesetzt wurden nicht autorisiert repariert oder modifiziert wurden schwere u ere Besch digungen aufweisen welche nicht bei...

Page 3: ...s equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However ther...

Page 4: ...ederherstellung der Standardeinstellungen 17 Tempor re Deaktivierung der Netzfilterregeln 18 Konfiguration 19 bersicht der Funktionen und Standardeinstellungen 19 Bedienung des On Screen Displays am A...

Page 5: ...innerhalb des OSDs ausw hlen 48 Wiederherstellung der Standardeinstellungen 49 Farbe der Informationseinblendung ndern 50 Anzeige der Informationseinblendung 51 Transparenz des On Screen Displays eins...

Page 6: ...vice has been disconnected from all power sources Disconnect all power plugs and all power supplies of the device D branchez toutes les sources d alimentation Avant l installation assurez vous que l a...

Page 7: ...Sie bei der Verlegung der Kabel Stolperfallen Geerdete Spannungsquelle verwenden Betreiben Sie dieses Ger t nur an einer geerdeten Spannungsquelle Verwenden Sie ausschlie lich das G D Netzteil Betreib...

Page 8: ...auchte Batterien d rfen nicht in den Hausm ll geworfen werden Beachten Sie die g ltigen Vorschriften zur Entsorgung elektronischer Produkte CAUTION Risk of explosion if the battery is replaced by an i...

Page 9: ...rwenden Es ist nicht zul ssig Lichtwellen Module zu verwenden die nicht der Laser Klasse 1 gem EN 60825 1 2014 entsprechen Durch die Verwendung solcher Module kann die Einhaltung von Vorschriften und...

Page 10: ...chnermoduls erfolgen Verf gbare Ger tevarianten Innerhalb der DL DVI Vision Fiber Serie sind verschiedene Varianten verf gbar die die zus tzliche bertragung von USB 2 0 Signalen erlauben Lieferumfang...

Page 11: ...uf Seite 4 WICHTIG Stellen Sie bei der Standortwahl der Ger te sicher dass die zul ssige Umgebungstemperatur siehe Technische Daten auf Seite 60 in der unmittelbaren N he eingehalten und nicht durch a...

Page 12: ...d Maus des Arbeitsplatzes anschlie en Keyb Mouse Schlie en Sie die USB Maus und oder die Tastatur des Arbeitsplatzes an Generic In der Standardeinstellung k nnen Sie an diese Schnittstelle eine weiter...

Page 13: ...ansmission Rx des Rechnermoduls angeschlossen ist Transmission Rx Stecken Sie den LC Stecker des Glasfaserkabels ein das an die Schnittstelle Transmission Tx des Rechnermoduls angeschlossen ist WICHTI...

Page 14: ...Schnittstellen der ARU und der ARU2 Varianten unter st tzen unterschiedliche Datenraten ARU Varianten Full Speed ARU2 Varianten Hi Speed WICHTIG Die Daten bertragung der am Arbeitsplatzmodul angeschl...

Page 15: ...ion Rx Stecken Sie den LC Stecker des Glasfaserkabels ein das an die Schnittstelle Transmission Tx eines kompatiblen Rechnermoduls oder Matrixswit ches angeschlossen ist HINWEIS Mit den zus tzlich ver...

Page 16: ...ertes Kaltger tekabel ein Red Power Stecken Sie ein mitgeliefertes Kaltger tekabel ein Hierdurch wird eine zweite redundante Stromversorgung des Arbeitsplatzmoduls erreicht Main Power Red Power Serial...

Page 17: ...n ab Seite 58 On Screen Display des Arbeitsplatzmoduls Beim Start des Arbeitsplatzmoduls werden Informationen ber den Startvorgang sowie die Firmware Versionen und ID Nummern der verbundenen Module au...

Page 18: ...die Zeile Interfaces und bet tigen Sie die Eingabetaste 4 Erfassen Sie im Abschnitt Interface A folgende Daten HINWEIS Im Auslieferungszustand sind folgende Einstellungen vorausgew hlt IP Adresse der...

Page 19: ...Sie die Zeile Interfaces und bet tigen Sie die Eingabetaste 4 Erfassen Sie im Abschnitt Main Network folgende Daten 5 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen Netmask G...

Page 20: ...g des Rechners wie der an beiden Arbeitspl tzen freigeschaltet Alternativ zur konkurrierenden Bedienung des Rechners durch die Arbeitspl tze kann die exklusive Bedienung s Seite 15 aktiviert werden Ve...

Page 21: ...etaste um die in der Zeile angezeigt Operation auszuf hren turn off Steckdose n ausschalten turn on Steckdose n einschalten HINWEIS Nach Aktivierung der exklusiven Bedienung des KVM Extenders an einem...

Page 22: ...tes und halten Sie diesen gedr ckt 3 Halten Sie den Taster weiterhin gedr ckt und schalten Sie das Ger t ein 4 Sobald die gr ne System LED schnell blinkt lassen Sie die Taste los HINWEIS Um die verse...

Page 23: ...lterregeln den Zugang auf die Webappli kation k nnen Sie die Netzfilterregeln tempor r deaktivieren um diese anschlie end zu editieren So deaktivieren Sie die eingerichteten Netzfilterregeln tempor r...

Page 24: ...des Hotkeys Strg 25 nderung der OSD Taste Num 26 On Screen Display mit doppeltem Tastendruck starten ausgeschatet 27 nderung der Exklusiv Taste Druck 28 nderung der Zeitspanne der Eingabesperre 1 Seku...

Page 25: ...latz So starten Sie das On Screen Display 1 Starten Sie das On Screen Display mit dem Hotkey Strg Num Standard Funktion Standardeinstellung Seite Wiederherstellung der Standardeinstellungen 49 Farbe d...

Page 26: ...zeigt Listenfeld Im Listenfeld werden die Men eintr ge des ausgew hlten Men s aufgef hrt Zu unterscheiden sind zwei Arten von Men eintr gen Men punkte mit Untermen Diese Eintr ge werden mit drei Punkt...

Page 27: ...Men ansicht und zeigt das bergeordnete Men an Falls Eingaben ge ndert aber nicht gespeichert wurden erhal ten Sie diesbez glich eine Meldung Tabulatortaste Verwenden Sie diese Taste um die Positionsma...

Page 28: ...terst tzten Sprachen in Form von Flaggen anzeigt 2 Schalten Sie mit einem Klick auf die gew nschte Flagge die Sprache um HINWEIS Grundlegende Informationen zu den Systemvoraussetzungen der erfor derli...

Page 29: ...der Webapplikation So beenden Sie die Webapplikation 1 Klicken Sie auf das Benutzersymbol rechts oben 2 Klicken Sie auf Abmelden um die aktive Sitzung zu beenden WICHTIG Verwenden Sie immer die Abmeld...

Page 30: ...Eingabetaste 3 W hlen Sie die Zeile Hotkey und bet tigen Sie die Eingabetaste 4 W hlen Sie im Abschnitt Modifier mindestens eine der aufgef hrten Hotkey Modifizierertasten durch Markierung des entspr...

Page 31: ...le Key durch Bet tigung der F8 Taste eine OSD Taste aus welche gemeinsam mit der bzw den Hotkey Modifizierertaste n den Aufruf des On Screen Displays bewirkt Num Num Taste Standard Pause Pause Taste I...

Page 32: ...Taste Alt Gr OSD Aufruf mit doppeltem Druck auf die Alt Gr Taste Win OSD Aufruf mit doppeltem Druck auf die Windows Taste Shift OSD Aufruf mit doppeltem Druck auf die Umschalt Taste Print OSD Aufruf m...

Page 33: ...ie das On Screen Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile System setup und bet tigen Sie die Eingabetaste 3 W hlen Sie die Zeile Hotkey und bet tigen Sie die Eingabetaste 4 W hl...

Page 34: ...00 Sekunden eingestellt werden So ndern Sie die Zeitspanne der Eingabesperre Verwandtes Thema Exklusive Bedienung des KVM Extenders auf Seite 15 OSD 1 Starten Sie das On Screen Display mit dem Hotkey...

Page 35: ...w hlen Sie die Berechtigung f r exklusiven Zugriff eines Arbeitsplatzes HINWEIS Nach Aktivierung der exklusiven Bedienung des KVM Extenders an einem Arbeitsplatz blinken an der Tastatur des gesperrten...

Page 36: ...rechtigung f r exklusiven Zugriff eines Arbeitsplatzes 1 Klicken Sie im Men auf KVM Extender 2 Klicken Sie auf das zu konfigurierende Rechnermodul CPU und anschlie end auf Konfiguration 3 Klicken Sie...

Page 37: ...er vom Rechnermodul zum Arbeitsplatzmodul bertragen 4 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen Config Panel So w hlen Sie die Berechtigung f r exklusiven Zugriff eines A...

Page 38: ...gabetaste falls Sie die Videobetriebsart des lokalen Arbeitsplatzen am CPU Modul einstellen m chten 3 W hlen Sie in der Zeile Video mode durch Bet tigung der F8 Taste zwischen folgenden Optionen alway...

Page 39: ...n 5 W hlen Sie im Feld Bildanzeige zwischen folgenden Optionen Immer an Das Bild des Rechners wird sowohl am Monitor des aktiven als auch am Monitor des konkurrierenden Arbeitsplatzes ausgegeben Stand...

Page 40: ...Start des Extenders Bei Auswahl der Bildanzeige Option Permanent aus s Seite 33 f des Rechner und des Arbeitsplatzmoduls zeigen beide Module nach einem Neustart des Extenders kein Bild an Erst nach ei...

Page 41: ...das EDID Profil eines Monito res eingelesen und durch den KVM Extender an den angeschlossenen Rechner bermittelt werden Ausf hrliche Informationen hierzu finden Sie im separaten Handbuch zur Webappli...

Page 42: ...D Profils oder eines vom Benutzer in der Webapplikation eingelesenen Profils 4 Falls Sie die Option user gew hlt haben w hlen Sie die Zeile Assign EDID und bet tigen Sie die Eingabetaste W hlen Sie mi...

Page 43: ...tellt HINWEIS Abh ngig vom Bildinhalt k nnen gegebenenfalls leichte Farbstufen bei Reduzierung der Farbtiefe erkennbar werden OSD 1 Starten Sie das On Screen Display mit dem Hotkey Strg Num Standard 2...

Page 44: ...sabbruch OSD Einblendung des Hinweises Frozen und der vergangenen Zeit seit dem Verbindungsabbruch frame OSD Anzeige des farbigen Rahmens frame und Einblendung des Hinweises Frozen OSD 5 Bet tigen Sie...

Page 45: ...Starten Sie das On Screen Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Console setup und bet tigen Sie die Eingabetaste Der Freeze Modus wird f r jeden Videokanal des Arbeitsplatzm...

Page 46: ...cken Sie auf den Reiter Videokan le 4 Klicken Sie bei Einsatz eines Multichannel Ger tes auf den gew nschten Videokanal und anschlie end auf Konfiguration 5 W hlen Sie im Feld DDC CI Monitor zwischen...

Page 47: ...unver ndert an das Rechner modul bertragen EINGABEGER T EINSTELLUNG PC Tastatur mit Standard Tastaturlayout PC Standard PC Tastatur mit zus tzlichen Multimedia Tasten Multimedia Apple Keyboard mit Zif...

Page 48: ...das als Scancode bezeichnet wird Es gibt zwei gebr uchliche Scan code Sets Sets 2 und 3 die verschiedene Scancodes beinhalten Der KVM Extender interpretiert in der Standardeinstellung alle Eingaben e...

Page 49: ...rung des Scancode Sets 3 f r PS 2 Tastatureingaben 4 Bet tigen Sie die F2 Taste zur Speicherung der durchgef hrten nderungen Die Tastatur wird nach dem erneuten Einschalten initialisiert und das ausge...

Page 50: ...Hotkey Strg Num Standard 2 W hlen Sie die Zeile Console setup und bet tigen Sie die Eingabetaste falls Sie die Einstellung f r den entfernten Arbeitsplatz am CON Modul einstellen m chten W hlen Sie d...

Page 51: ...Klicken Sie auf den Reiter CON falls Sie die Einstellung des entfernten Arbeitsplatzes am CON Modul einstellen m chten 5 W hlen Sie im Feld USB Auto Refresh des Abschnitts Konfiguration eine der fol g...

Page 52: ...falls Sie den Bildschirmschoner des lokalen Arbeitsplatzes am CPU Modul einstellen m chten 3 Geben Sie in der Zeile Screensaver min die Wartezeit 1 bis 999 Minuten des Bildschirmschoners ein Der Wert...

Page 53: ...n Screen Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Console setup und bet tigen Sie die Eingabetaste 3 W hlen Sie in der Zeile OSD key layout durch Bet tigung der F8 Taste zwi sch...

Page 54: ...platzmoduls mit dem local hotkey Standard Alt Num falls Sie nur die lokalen Einstellungen des Arbeits platzmodul zur cksetzen m chten 2 W hlen Sie die Zeile System setup entferntes OSD bzw Console uti...

Page 55: ...lb blue blau fuchsia magenta light turquoise hellt rkis white wei OSD 1 Starten Sie das On Screen Display mit dem Hotkey Strg Num Standard 2 W hlen Sie die Zeile Console setup und bet tigen Sie die Ei...

Page 56: ...betaste 3 W hlen Sie die Zeile Personal Profile und bet tigen Sie die Eingabetaste 4 W hlen Sie in der Zeile Display durch Bet tigung der F8 Taste zwischen folgenden Optionen Aus Informationseinblendu...

Page 57: ...in der Zeile OSD transparency durch Bet tigung der F8 Taste zwi schen folgenden Optionen high hohes Durchscheinen des Bildschirminhalts average mittleres Durchscheinen des Bildschirminhalts Standard...

Page 58: ...n Sie die Zeile Console setup und bet tigen Sie die Eingabetaste 3 W hlen Sie die Zeile Personal Profile und bet tigen Sie die Eingabetaste 4 W hlen Sie die Zeile Close OSD when inactive for s und bet...

Page 59: ...n Sie die Eingabetaste An der aktuellen Position der Informationsein blendung erscheint das rechts abgebildete Men 5 Verwenden Sie die Pfeiltasten oder die Maus um das Men an die gew nschte Position z...

Page 60: ...ossene Rechner schon w hrend des Bootvorgangs Zugriff auf die Eigenschaften des entfernten Monitors hat ist eine Cache Funktion in den KVM Extender integriert Auch wenn das Rechner oder das Arbeitspla...

Page 61: ...figurierbare Tastenkombinatio nen Select Keys w hlen So schalten Sie den Kanal durch Verwendung der Taster um Bet tigen Sie den Taster des gew nschten Kanals um diesen zu aktivieren So schalten Sie de...

Page 62: ...sprechenden Pins auf Arbeitsplatzmodul Rechnermodul RS232 Stecker RS232 Buchse Pin Nr Leitung Arbeitsplatz modul Rechner modul 1 DCD Data Carrier Detect Eingang Ausgang 2 RxD Receive Data Eingang Ausg...

Page 63: ...st ausgeschaltet oder die Verbindung mit dem Stromnetz nicht hergestellt Status Trans an Verbindung zur Gegenstelle hergestellt aus Verbindung zur Gegenstelle nicht hergestellt System an Ger t betrieb...

Page 64: ...e Verbindung zur Gegenstelle aufgebaut werden Pr fen Sie die Kabelverbindung der Tx Schnitt stelle mit der Gegenstelle blinkt schnell inkompatibles SFP Modul aus Verbindung zur Gegenstelle kann nicht...

Page 65: ...chse Service 1 Mini USB Buchse Typ B Audio bertragungsart transparent bidirektional Aufl sung 24 bit digital Stereo Abtastrate 96 kHz Bandbreite 22 kHz RS232 bertragungsart transparent bertragungsrate...

Page 66: ...Speed Variante ARU2 Spezifikation USB 2 0 bertragungsart transparent bertragungsrate max 480 Mbit s Unterst tzte Ger te High Power Devices bis 500 mA Reichweite max 10 000 Meter Hauptstrom versorgung...

Page 67: ...ei Variante ARU werden zus tzlich die Signale der USB 2 0 Ger te ber dieses Kabel bertragen 1 LC Duplex Buchse USB 2 0 Variante ARU2 1 LC Duplex Buchse Transmission 2 Variante CON 2 1 LC Duplex Buchse...

Page 68: ...240V 60 50Hz 0 3 0 2A 14 7 W AR CON 2 100 240V 60 50Hz 0 3 0 2A 15 6 W ARU CON 100 240V 60 50Hz 0 6 0 3A 27 5 W ARU CON 2 100 240V 60 50Hz 0 6 0 3A 28 1 W ARU2 CON 100 240V 60 50Hz 0 6 0 3A 29 0 W Ge...

Page 69: ...mpfindlichkeit Stressed PS 138 W 50 m MMF SINGLEMODE S BERTRAGUNGSMODUL Daten bertragung Art Lichtwellenleiter 2 Glasfasern Schnittstellentyp LC Duplex Kabell nge max Singlemode 9 125 m Klasse OS1 5 K...

Page 70: ......

Page 71: ...Deutsch...

Page 72: ...will not provide warranty for devices that Are not used as intended Are repaired or modified by unauthorized personnel Show severe external damages that was not reported on the receipt of goods Have...

Page 73: ...s equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However ther...

Page 74: ...setting the default settings 17 Temporarily deactivating the netfilter rules 18 Configuration 19 Overview of functions and default settings 19 Operating the on screen display at the console 20 Showing...

Page 75: ...ard layout for inputs via OSD 48 Resetting the default settings 49 Changing the colour of the information display 50 Information display 51 Adjusting the transparency of the on screen display 52 Autom...

Page 76: ...ation assurez vous que l appareil a t d branch de toutes les sources d alimentation D branchez toutes les fiches d alimentation et toutes les alimenta tions lectrique de l appareil Trennen Sie alle Sp...

Page 77: ...Avoid tripping hazards while laying cables Only use a grounded voltage source Operate this device by using a grounded voltage source Use only the provided G D power pack Operate this device with the...

Page 78: ...t dispose of batteries in municipal waste Check local regulations for the disposal of electronic products ATTENTION Il y a danger d explosion s il y a remplacement incorrect de la batterie Mettre au r...

Page 79: ...t is not permitted to use fibre optic modules which do not meet the requirements of laser class 1 in accordance to EN 60825 1 2014 By using such modules the compli ance with regulations and advices fo...

Page 80: ...console of the computer module Available variants The DL DVI Vision Fiber series provides further variants that additionally enable the transmission of USB 2 0 signals Package contents 1 user module D...

Page 81: ...on page 4 IMPORTANT When choosing a location for the devices please ensure to comply with the ambient temperature limit see Technical data on page 60 ff close to the device The ambient temperature li...

Page 82: ...network Connecting keyboard and mouse of consoles Keyb Mouse Connect the mouse and or the keyboard of the console to this interface Generic In the default settings you can use this interface to connec...

Page 83: ...face of the computer module Transmission Rx Insert the LC plug of the fibre optic cable connected to the Transmis sion Tx interface of the computer module IMPORTANT If the generic HID mode is active t...

Page 84: ...t different data rates ARU variants full speed ARU2 variants high speed IMPORTANT Transmitting data of USB devices connected to the user module between the user module and the computer module and vice...

Page 85: ...Rx Insert the LC plug of the fibre optic cable connected to the Transmis sion Tx interface of a compatible computer module or matrix switch NOTE With the also available CON 2 versions of the user mod...

Page 86: ...er Insert one of the supplied IEC cables here Red Power To provide a second redundant power supply connect a portable power pack to this interface Main Power Red Power Serial DVI D DL Out Transmission...

Page 87: ...the chapter Status LEDs on page 58 ff On screen display of the user module When starting the user module information about the starting process as well as the firmware versions and IDs of the connecte...

Page 88: ...Interfaces and press Enter 4 Enter the following data under Interface A NOTE In the default settings the following settings are preselected IP address of Network interface A address is obtained via DH...

Page 89: ...Enter 3 Select the entry Interfaces and press Enter 4 Enter the following data under Main Network 5 Press F2 to save your settings Netmask Enter the netmask of the network The operational mode DHCP do...

Page 90: ...matic input lock has been lifted both consoles are again able to oper ate the computer As an alternative to operate the computer concurrently via consoles the exclusive operation see page 15 can be ac...

Page 91: ...ons turn off turn power outlet s off turn on turn power outlet s on NOTE After the exclusive operation of the KVM extender has been activated at one console the Caps Lock Num as well as the Scroll Loc...

Page 92: ...vice 3 Keep the button pressed and switch on the device 4 Release the button as soon as the green Switch LED is fast blinking NOTE As protection against pressing the button accidentally it is located...

Page 93: ...etfilter rules If the currently adjusted netfilter rules prevent the access to the web application they can be can temporarily deactivated in order to be edited How to temporarily deactivate the netfi...

Page 94: ...OSD key Num 26 Opening the on screen display via double keypress turned off 27 Changing the exclusive key Print 28 Changing the time span of the input lock 1 second 29 Right for exclusive access to th...

Page 95: ...w to open the on screen display 1 Press Ctrl Num standard to open the on screen display Function Default setting Page Resetting the default settings 49 Changing the colour of the information display l...

Page 96: ...shows the title of the current menu List field The list field shows the menu items of the selected menu there are two types of menu items Menu items with submenus These items are displayed with three...

Page 97: ...n a submenu Esc This key closes the displayed menu and shows the superior menu A message is shown if entries are changed but not saved Tab key Use this key to move the cursor within the list field fro...

Page 98: ...n 1 Click on the country flag at the top right A submenu opens displaying all supported languages in the form of flags 2 Change the language by clicking on the desired flag NOTE The separate manual pr...

Page 99: ...active session of the web application How to close the web application 1 Click on the user icon at the top right 2 Click on Logout to exit the active session IMPORTANT To protect the web application a...

Page 100: ...display 2 Select the row System setup and press Enter 3 Select the row Hotkey and press Enter 4 Under Modifier select at least one of the listed hotkey modifiers by selecting the box with the arrow k...

Page 101: ...ey press F8 to select an OSD key Now you can open the OSD when pressing the OSD key together with the hotkey modifier s Num Num key default Pause Pause key Insert Insert key Delete Delete key Home Hom...

Page 102: ...ce Alt Gr OSD is opened by pressing the Alt Gr key twice Win OSD is opened by pressing the Windows key twice Shift OSD is opened by pressing the Shift key twice Print OSD is opened by pressing the Pri...

Page 103: ...ress Ctrl Num default to open the on screen display 2 Select the row System setup and press Enter 3 Select the row Hotkey and press Enter 4 Under Exclusive key press F8 to select on of the following o...

Page 104: ...ds How to change the timespan of the input lock Related topic Operating the KVM extender exclusively on page 15 OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row System setup...

Page 105: ...xtender again How to select the right to exclusively operate a console NOTE After the exclusive operation of the KVM extender has been activated at a console the Caps Lock Num and Scroll Lock LEDs are...

Page 106: ...ule into RS422 interfaces Config Panel 1 In the menu click on KVM extender 2 Click on the computer module CPU you want to configure and then click on Configuration 3 Click on the tab General 4 Click...

Page 107: ...e computer module to the console module via separately available G D RS232 422 adapters 4 Press F2 to save your settings Config Panel 1 In the menu click on KVM extender 2 Click on the computer module...

Page 108: ...ter if you want to adjust the video mode for the local console at the CPU module 3 Under Video mode press F8 to select one of the following options always on The computer screen is displayed on both t...

Page 109: ...the field Image display select one of the following options Always on The computer screen is displayed on both the monitor of the active and the monitor of the concurrent console default Temporarily...

Page 110: ...onsole Active console after starting an extender When selecting the Image display option Permanently off see page 33 f at both the computer and the console module both modules do not show an image aft...

Page 111: ...e web application Config Panel to read out the EDID profile of a monitor The KVM extender then transmits it to the connected com puter Detailed information about this topic is given in the separate ma...

Page 112: ...e or a profile that has been read out via web application 4 If the option user has been selected select the row Assign EDID and press Enter Use the arrow keys to select the profile you want the activa...

Page 113: ...on has been interrupted NOTE Depending on the image contents reducing the colour depth may result in slight colour grades OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Ta...

Page 114: ...D shows Frozen and the time passed since disconnection frame OSD shows a coloured frame frame and Frozen OSD 5 Press F2 to save your settings Config Panel 1 In the menu click on KVM extender 2 Click o...

Page 115: ...port of a user module OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Console setup and press Enter The Freeze mode is adjusted separately for each video channel of the use...

Page 116: ...onfiguration 3 Click on the tab Video channels 4 When using a multi channel device click on the desired video channel and then click on Configuration 5 Select one of the options given under DDC CI mon...

Page 117: ...er module without being altered INPUT DEVICE SETTING PC keyboard with default keyboard layout PC default PC keyboard with additional multimedia keys Multimedia Apple keyboard with numeric keypad A1243...

Page 118: ...you press a key at the PS 2 keyboard the keyboard processor sends a data packet that is called scan code The two common scancode sets sets 2 and 3 contain differ ent scancodes In the default configura...

Page 119: ...F2 to save your settings After you turn the KVM extender on again the keyboard is initialised and the selected scancode set is applied Config Panel 1 In the menu click on KVM extender 2 Click on the...

Page 120: ...ut devices OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Console setup and press Enter if you want to change this setting of the remote console at the CON module Select t...

Page 121: ...CPU module Click on the tab CON if you want to change this setting of the remote workstation on the CON module 5 In the USB auto refresh field of the Configuration section select one of the fol lowing...

Page 122: ...nd press Enter if you want to adjust the screensaver of the local console at the CPU module 3 Under Screensaver min enter a waiting period 1 to 999 minutes for the screensaver Entering the value 0 dis...

Page 123: ...ess Ctrl Num default to open the on screen display 2 Select the row Console setup and press Enter 3 Under OSD key layout press F8 to select one of the following options German English US English UK Fr...

Page 124: ...he settings of the extender system Open the local OSD of the user module by pressing the local hotkey default Alt Num if you want to reset the local settings of the user module 2 Select the row System...

Page 125: ...ark yellow dark blue purple dark turquoise silver yellow blue fuchsia light turquoise white OSD 1 Press Ctrl Num default to open the on screen display 2 Select the row Console setup and press Enter 3...

Page 126: ...r 3 Select the row Personal Profile and press Enter 4 Under Display press F8 to select between the following options Off information display is turned off Temporary information display is shown tempor...

Page 127: ...Profile and press Enter 4 Under OSD transparency press F8 to select on of the following options high high transparency of the screen content average average transparency of the screen content default...

Page 128: ...SD 1 Press Ctrl Num default to open the on screen display 2 Select the row Console setup and press Enter 3 Select the row Personal Profile and press Enter 4 Select the row Close OSD when inactive for...

Page 129: ...tup and press Enter 3 Select the row Personal Pprofile and press Enter 4 Select the row Set display position and press Enter The message on the right is shown at the current position of the informatio...

Page 130: ...ed to the computer module DL DVI Vision Fiber CPU can already access the features of the remote monitor dur ing booting the KVM extender contains a cache function Even when the computer module or the...

Page 131: ...via the switches on the front or via configurable key combinations select keys To switch the channel using the buttons Press the button of the desired channel to activate it To switch the channel usi...

Page 132: ...assigned to the according pins User module Computer module RS232 plug RS232 socket Pin no Line User module Computer module 1 DCD Data Carrier Detect Input Output 2 RxD Receive Data Input Output 3 TxD...

Page 133: ...power network could not be established Status Trans on The connection to the remote station has been established off The connection to the remote station could not be established System on Device is r...

Page 134: ...stablish a connection to the remote station Check the cable connection of the Tx interface with the remote station fast blinking incompatible SFP module off The connection to the opposite site could n...

Page 135: ...cket type B Audio Transmission type transparent bidirectional Resolution 24 bit digital Stereo Sampling rate 96 kHz Bandwidth 22 kHz RS232 Transmission type transparent Transmission rate max 115 200 b...

Page 136: ...high speed ARU2 variant Specification USB 2 0 Transmission type transparent Transmission rate max 480 Mbit s Supported devices high power devices up to 500 mA Range max 10 000 meters Main power supply...

Page 137: ...U vari ant the signals of USB 2 0 devices are additionally transmitted via this cable 1 LC duplex socket USB 2 0 ARU2 variant 1 LC duplex socket Transmission 2 CON 2 variant 1 LC duplex socket Casing...

Page 138: ...V 60 50Hz 0 3 0 2A 14 7 W AR CON 2 100 240V 60 50Hz 0 3 0 2A 15 6 W ARU CON 100 240V 60 50Hz 0 6 0 3A 27 5 W ARU CON 2 100 240V 60 50Hz 0 6 0 3A 28 1 W ARU2 CON 100 240V 60 50Hz 0 6 0 3A 29 0 W Device...

Page 139: ...A Sensitivity Stressed PS 138 W 50 m MMF SINGLEMODE S TRANSMISSION MODULE Data transmission Type Optical fibres 2 fibres Type of interface LC duplex Cable length max Singlemode 9 125 m Class OS1 5 Kil...

Page 140: ......

Page 141: ...English...

Page 142: ......

Page 143: ...English...

Page 144: ...e Leimbach 9 57074 Siegen Germany http www gdsys de sales gdsys de Das Handbuch wird fortlaufend aktualisiert und im Internet ver ffentlicht The manual is constantly updated and available on our websi...

Reviews: