Installation Guide
G&D CATCenter NEO
·
20
Back panel
Every RJ45 interface at the back panel of the
CATCenter
system provides additional
status LEDs. These LEDs have the following function:
Section LED Meaning
yellow
The port is currently occupied by a user.
Console
green
Connected to an
UCON
user module
.
yellow
The port is currently occupied by a user.
CPU
green
Connected to a
CATpro2
target module
.
yellow
Lights up constantly during a full-duplex connection.
Lights up during a half-duplex connection (collision).
Network
green
Indicates the connection status.
Flashes during activity.
The target modules of the
CATpro2
series
The blinking status LEDs at the
CATpro2
target modules have the following meaning:
LED-Verhalten Meaning
flashes 3 times
per second:
Not connected to the
CATCenter
system.
flashes every
1,5 sec.:
Connected to the
CATCenter
system but no target computer
is accessing.
lights up:
Connected to the
CATCenter
system and a target computer is
accessing.
flickers:
Connected to the
CATCenter
system, a target computer is
accessing and keyboard/mouse data are being received.