background image

 

E

D

IT

IE

 1

2

1

2

6

3

1

4

 

MG-Line 
Noverta & Noverta Premium
000030098 

Gebruiksaanwijzing  User Manual  Mode l’emploi 

Gebrauchsanweisung

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Noverta & Noverta Premium

 

Gebrauchsanweisung 

Summary of Contents for MG-Line Noverta

Page 1: ...EDITIE 12126314 MG Line Noverta Noverta Premium 000030098 Gebruiksaanwijzing User Manual Mode l emploi Gebrauchsanweisung Noverta Noverta Premium Gebrauchsanweisung...

Page 2: ...2 Installation 35 Installing the product 35 Fitting storage racks 36 Power supply 36 Chapter 3 Using the appliance 37 Prior to use 37 Thermostat 38 Filling the cabinet 39 Chapter 4 Maintenance 40 Cle...

Page 3: ...t and will render the warranty invalid Correct use of the product will prolong its useful life All installations have to conform to local governmental and municipal legislation and the machine Directi...

Page 4: ...cation When exposed to fire the container can burst open or explode Always ensure that there is sufficient ventilation in the room where the appliance is located Never open the machine unit Refrigeran...

Page 5: ...alcohol standing upright and tightly closed Ensure that ventilation grilles both in and outside the cabinet remain unobstructed In case of emergency the plug should be removed from the socket After u...

Page 6: ...User Manual 33 Product description 1 Type plate inside 2 Door 3 Air in outlet 4 On off switch 5 Thermostat 1 2 3 3 4 5...

Page 7: ...mal performance within certain ambient temperatures This product is suitable for the following classification N from 16 C to 32 C Refrigerant A Refrigerant like R134a can cause burns or after exposure...

Page 8: ...10cm space around the refrigerator Be very careful never to obstruct the air inlets and outlets Installing the product Place the product on a smooth surface 1 Place the product at his position 2 Make...

Page 9: ...iginal cable supplied by the producer In case of emergency remove the plug lead from the socket The socket should be within easy reach of the cabinet Check for the correct power supply referred to the...

Page 10: ...use Clean the cabinet prior to use For further details we refer to chapter maintenance Leave the installation to stand for at least 2 hours before switching on the cabinet Plug into a grounded power...

Page 11: ...o return to normal visualisation To change the set point 1 Push the SET key for more than 2 sec and then push the SET key again 2 The value of the set point will be displayed and the C LED starts blin...

Page 12: ...of the products Beverages with a high alcohol percentage should always be stored properly sealed in an upright position To guarantee optimal performance and air circulation the air vents of the cabine...

Page 13: ...s regular cleaning This product has a maintenance free condenser Check and clean the magnetic seals on a regular basis If the seal is not airtight it will have a negative effect on the refrigeration p...

Page 14: ...e if necessary Remove contents which may obstruct ventilation Defrost evaporator Thermostat or compressor is defect Fan evaporator or condenser is defect Contact your local service organization Temper...

Page 15: ...0 L Weight 56 kg 56 kg Illumination 1 x 3 Watt 1 x 3 Watt Capacity tray 2 x 50 kg each door 2 x 50 kg each door Dimensions 602 x 506 x 840 850 mm 602 x 506 x 840 850 mm Type MG 140RG MG 140RGCS Power...

Page 16: ...134a Power consumption 130W R600a 130W R600a Internal volume 150 L 150 L Weight 58 kg 58 kg Illumination 1 x 3 Watt 1 x 3 Watt Capacity tray 2 x 50 kg each door 2 x 50 kg each door Dimensions 602 x 50...

Page 17: ...consumption 130W R600a Internal volume 150 L Weight 58 kg Illumination 1 x 3 Watt Capacity tray 2 x 50 kg each door Dimensions 602 x 526 x 900 910 mm Type MG 250G MG 250GCS Power consumption 181 Watt...

Page 18: ...y 2 x 50 kg each door 2 x 50 kg each door Dimensions 900 x 506 x 900 910 mm 900 x 506 x 900 910 mm Type MG 250SD Power consumption 181 Watt R134a Power consumption 137W R600a Internal volume 250 L Wei...

Page 19: ...Watt Capacity tray 2 x 50 kg per deur 2 x 50 kg per deur Dimensions 1200 x 506 x 900 910 mm 1200 x 506 x 900 910 mm Type MG 275SD Power consumption 316 Watt R134a Power consumption 235W R600a Interna...

Page 20: ...4 Watt Capacity tray 2 x 50 kg per deur 2 x 50 kg per deur Dimensions 1350 x 506 x 900 910 mm 1350 x 506 x 900 910 mm Type MG 315SD Power consumption 316 Watt R134a Power consumption 235W R600a Intern...

Page 21: ...User Manual 48...

Page 22: ...general Gamko Holding BV applies the CECED interpretation European Committee of Manufacturers of Electrical household appliances according to which the WEEE legislation is applicable portable air con...

Page 23: ...ble to products that are not included in the scope of these national legislations should be omitted The directive does not apply to products sold outside the European Union In case the product is to b...