background image

Model 550550

Control Un it

User’s Manual

This User’s Manual is also available online in  

English, French, German, Italian, Japanese, and Spanish  

at www.gameready.com under Products. 

Summary of Contents for 550550

Page 1: ...Model 550550 Control Unit User s Manual This User s Manual is also available online in English French German Italian Japanese and Spanish at www gameready com under Products...

Page 2: ...___________________ 11 UL Classification_____________________________________________ 13 Cleaning____________________________________________________ 14 Maintenance____________________________________...

Page 3: ...however a Wrap must be attached to the System to begin treatment Power Cord AC Adapter Connector Hose Wrap Heat Exchanger Sleeve Control Unit with ACCEL Technology Welcome Packet Slee p Time Time Run...

Page 4: ...ions Game Ready with ACCEL Technology proactively aids lymphatic function encourages cellular oxygen supply and stimulates tissue repair REGISTER YOUR PRODUCT Please complete your Warranty Registratio...

Page 5: ...ause a treatment or to stop Add Time Use this button to add time in Manual Mode does not work in Program Mode You can add up to 90 minutes Treatment must be paused in order to add or subtract time Sub...

Page 6: ...odes Indicates sleep mode time Indicates remaining battery capacity Temperature Average Wrap Temperature Indicates an estimate of the average temperature of the Wrap averages the temperature of the wa...

Page 7: ...amount of run time remaining Sleep time count down bars When selecting a program Pressure Displays pressure Displays amount of time unit will run Displays amount of time unit will sleep Sleep Time Ti...

Page 8: ...t the ice life If you will be using the System with a Game Ready supplied battery pack please consult the instructions for use that accompanied that battery pack for usage details Warning Position the...

Page 9: ...The power indicator light orange color on the Control Unit should illuminate If it does not illuminate check to make sure that the AC Adapter is firmly connected in all locations and that the outlet i...

Page 10: ...y the selected Wrap consult the Use Guide for each Wrap for application instructions Warning Do not place directly against open wounds sores rashes infections or stitches May be applied over clothing...

Page 11: ...provide less cold therapy Manual Mode Set the time by pushing the buttons Set the pressure by pushing the pressure button You can select from 4 pressure settings No pressure Low Pressure 5 15 mmHg Me...

Page 12: ...t post surgical and acute injuries to reduce edema swelling and pain where cold and compression are indicated It is intended to be used by or on the order of licensed healthcare professionals in hospi...

Page 13: ...use any AC adapter other than that provided by Game Ready Use of other adapters may result in electrical shock and will void the Game Ready warranty To avoid damage to your product do not operate the...

Page 14: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to other devices in the vicinity Howeve...

Page 15: ...ubmerge the Control Unit or allow any liquid to pool on the surface of the front panel of the Control Unit CONNECTOR HOSE The surface of the Connector Hose can be cleaned using a soft cloth and one of...

Page 16: ...Bag s main compartment and end panel Fill the reservoir with ice and water Attach the Connector Hose and the AC Adapter to the end panel of the Control Unit and plug the AC Adapter into a grounded ele...

Page 17: ...5012 and Hospital Grade Power Cord A Game Ready supplied Connector Hose A Game Ready Carry Bag A Game Ready supplied battery and charger A Dual Connector Hose The Game Ready Drain Mode Adapter s p e c...

Page 18: ...o kinks in the Wrap or Connector Hose Turn the Control Unit off and on again Turn the temperature knob to full cold until flow has been established Disconnect and reconnect the hose from the Control U...

Page 19: ...d back on again Check to see if the filter is clogged If that does not solve the problem turn the Control Unit off for 20 minutes to let the pump cool down before turning it on again to try again Low...

Page 20: ...RMA number on the outside of the package CoolSystems will not accept returned Game Ready Control Units without an RMA number on the package If you return the Game Ready Control Unit to CoolSystems you...

Page 21: ...s t r at i o n The Game Ready System including Control Unit Heat Exchanger Connector Hose AC Adapter and Power Cord comes with a 1 year warranty from date of purchase In the case of a manufacturer s...

Page 22: ...Unit User s Manual PN 702742 Rev H 2013 CoolSystems Inc All rights reserved Brought to you by CoolSystems Inc 1800 Sutter Street Suite 500 Concord CA 94520 1 888 GameReady 1 888 426 3732 1 510 868 210...