Programming/Operating Instructions for RF 120V-4 Remote Control Transmitter and Receiver 

 
 

Programming instructions: 

 

Each transmitter has its own unique internal address that is transmitted whenever a button is pressed. The 
receiver needs to be programmed to respond only to transmitters it is intended to operate with. The 
following steps configure the receiver to operate with a particular transmitter(s). Up to thirty transmitters 
can be programmed to one receiver. Please read the entire programming procedure before starting. Prior 
to programming the receiver, verify that the receiver is connected to the input power. When the receiver 
enters program mode, all previous transmitter addresses that were programmed will be erased from the 
receiver's memory. 

 

1.

 

Locate the pushbutton labeled "PROGRAM" on the receiver. Press and hold this button until the 
red LED next to the program button illuminates (approximately 5 seconds). The receiver is now 
in the transmitter program mode. Release the pushbutton. At this point all previously 
programmed transmitter addresses are erased from the receiver's memory. 

 

2.

 

Press  and  release  any  button  on  the  transmitter  and  verify  that  the  red  LED  on  the 
receiver extinguishes and then illuminates (blinks once). 

 

3.

 

Repeat previous step for additional transmitters that will operate with this particular receiver. 

 

The red LED on the receiver will extinguish and illuminate one time for the first transmitter 
being programmed, twice for the second, three times for the third, four times for the fourth etc. 
The receiver will not respond to transmitters that have already been programmed. 

 

4.

 

After 5-seconds of no switch being pressed on the transmitter(s) the receiver will return to 
normal operation. The red LED on the receiver will blink rapidly, then extinguish. The receiver 
is now in the normal mode of operation. This completes the programming instructions. The 
receiver will retain all of its programming even when power is removed. 

 
 

Operating Instructions

 

The remote control provides four independent 120 VAC outputs. Input power to the receiver is 120 
VAC, single-phase 60Hz. The 4 switched outputs provide LINE voltage to the loads and the neutral 
should be connected to the other side of the loads. The maximum current rating of all 4-outputs is 20-
amperes. 

 

Each output can be configured for either latching or momentary by configuring the corresponding DIP 
switches on the receiver. Selecting momentary output provides the 120 VAC output for as long as the 
transmitter “ON” switch is held down. Latching outputs will turn on the 120 VAC output when the 
transmitter “ON” switch is pressed and released, and the output can be turned off by pressing and 
releasing the corresponding “OFF” switch on the transmitter. 

 

The  receiver  has  a  terminal  block  for  connecting  auxiliary  switches  inputs  for  manual  control  of 
each output. The manual switches used should be momentary so the RF transmitter and switches will 
turn on/off each output. Note the auxiliary switch inputs are isolated from the line voltage. 

 

 

 

 

 

 

 