3. Fit Piezo Button 

 

Install piezo button through the trough 
ensuring that the coloured washer is in 
place.

 

 

Fit & tighten the supplied nut.

 

 

Connect it to the electronic control unit.

 

 

4. Install Piezo Button, Solenoid and Transformer 

 

Connect Piezo button, the solenoid & the power supply 
to the eletronic control unit. 

 

This unit is supplied with 2 x 3.2 metre extension leads 
for connecting to the power supply and solenoid. 

 

  

 

5. Fit Solenoid and Hose 

 

Fit flexi hose to solenoid and water supply. 

 

Fit flexi hose to outlet. 

6. Testing

 

 

Once the drinking tap has been installed and tested 
for leaks, the water height may be adjusted to suit the 
available pressure.  

 

To adjust water flow 

1.  Remove the blanking screw. 
2.  Adjust the water height by turning the regulator 

screw. 

3.  Replace blanking screw. 

Note:  The full range from minimum flow to 
maximum flow is only ¼ turn.

 

 
 

 