Version 1, 1 May 2020, Page
4
of
5
Version 1,30
th
April 2020, Page
4
of
5
7. Test
Once the bottle filler has been installed, turn on mains water and check for leaks and correct operation.
TROUBLESHOOTING
PROBLEM
CAUSE
RECTIFICATION
Leaks
Incorrectly installed.
Follow the installation instructions and
ensure the o-ring is correctly installed.
Check for debris in the outlet.
Spout still rotates
Grub screw incorrectly installed.
Ensure the spout inlet position hole is lined
up with the outlet grub screw hole. Re-
install grub screw.
Water is not flowing
Water is turned off
Turn on water
Inconsistent flow
Blocked top assembly
Remove top assembly and clean.