background image

Specialised commercial taps and valves

© Galvin Engineering Pty Ltd: 2015

Flowmatic

®

  Electronic Tapware & Control Valves

Flowmatic Automatic 24AC Concealed Wall Assembly for 

Basins and Troughs

TZ-FLOWTAPC24

December 2015

Pre Installation:

1.  Water conditions must meet Operation Requirements (bottom 

right of page) before proceeding.

2.  A pressure reduction valve may be required to comply with 

recommended maximum supply pressure.

3.  If your water pressure is outside the stated range please 

contact Galvin Engineering.

4.  Flush all supply lines to remove debris prior to the installation 

of this product.

5.  Fit line strainer (supplied) to protect the solenoid valve from 

debris.

6.  Access to the sensor, solenoid valve and transformer/GPO 

should be maintained for future maintenance.

7.  It is recommended that isolating valves be installed upstream 

to the solenoid valve to allow for servicing. 

8.  25 mm conduit should be used to house the leads so that 

wiring may be able to be removed.

9.  The unit is supplied with 3 metres of lead on the transformer 

and 3 metres of lead from the solenoid. Lead lengths up to 5 

metres may be accommodated (can be ordered separately).

10. Do not extend the existing leads on site without using the 

correct lead extension as this will void any warranty.

11. Connect the supplied electrical interference suppressor to 

each cable (1x transformer, 1x solenoid lead) as shown in 

Figure 1.

12. Ensure they are as close to the sensor face as possible.
13. Consider ease of operation when selecting a location to install 

the sensor.

14. The sensor may not work as intended if the sensor eye is 

installed in a position where light can be directed or reflected 

directly into the sensor eye. 

15. Most installation problems are due to damage to the unit 

during installation or inappropriate installation location. Please 

select the location carefully and take care with the installation

Operation Requirements

Maximum working pressure

500kpa

Minimum working pressure

100kpa

Recommended working pressure

350kpa

Maximum Temperature

75°C

Minimum Temperature

5°C

Power Supply

240V AC

The TZ-FLOWTAPC24 is a universal aesthetically pleasing, single temperature water control unit, 
which can be used for hand basins, sinks, or any application to initiate a controlled flow of water

Figure 1

General Installation Requirements:

1.  Suitable access for the service of all components must be 

provided.

2.  It is recommended that acoustic dampening products or 

materials be used in facilities where increased levels of sound 

protection is required.

3.  A water hammer arrestor may also be required.
4.  Please ensure that the requirements of AS/NZS 3500.1: 

Plumbing and Drainage are adhered to.

5.  The number of valves and simultaneous demand must be 

considered when sizing pipes. If other fixtures are connected 

to the supply line, calculations of flow rates and pressures 

must be undertaken to ensure adequate water supply.

6.  Limit the number of changes of directions in pipe work. This 

will result in less friction loss, better valve performance and 

reduce potential water cavitation noise.

7.  The use of isolating valves is recommended for servicing and 

to assist in the control of flow and volume of water.

8.  For personal installation assistance, please call our head office 

on 1300 514 074 and speak to our customer service staff.

Reviews: