Installation and Operating Manual - SGW(S) Vulcan

9

4. Technical specification

4.5. Scheme of the SGW(S) Vulcan 200 l - free-standing

650

Water drain

Magnesium anode

Summary of Contents for SGW 100

Page 1: ...lcan Capacity 100 l 120 l 140 l 200 l Protection Magnesium anode Titanium anode Type Free standing Wall mounted Please read the instructions carefully before beginning the installation and use of the product Cat No Serial No Date of manufacture QC www galmet eu Made in Poland ...

Page 2: ...40 l wall mounted 6 4 3 Technical specification of the SGW S Vulcan wall mounted 7 4 4 Scheme of the SGW S Vulcan 100 140 l free standing 8 4 5 Scheme of the SGW S Vulcan 200 l free standing 9 4 6 Technical specification of the SGW S Vulcan free standing 10 5 Titanium maintenance free active anode 11 5 1 Troubleshooting 11 6 Declaration of Conformity 12 7 Product fiche 13 Table of Contents ...

Page 3: ...correct installation of the valve and installation errors such as the lack of a pressure release valve in the cold water outlet installation The maximum pressure for a full opening of the safety valve must not exceed 0 67 MPa 3 Adequate protection of the boiler working together with the water heater ensures proper pro tection of the water heater coil 4 The water heater must be flushed of sediment ...

Page 4: ...ter is dirty A large amount of sediment in the tank Clean the tank of sediment Worn out magnesium anode Replace the magnesium anode not covered by the warranty Uwaga 1 At least once every 18 months replace the magnesium anode keep the receipt for the magnesium anode Regular replacement of the magnesium anode is a requirement for maintaining a warranty on the tank for an enamelled tank 2 It is not ...

Page 5: ... vessel for an open system Nprz expansion vessel Zb1 safety valve Z1 shut off valve on cold water inlet Z2 shut off valve on hot water outlet Z3 Z4 shut off valve on water inlet from the heating system to the coil Z5 shut off valve on the outlet hose from the heating installation P2 pump Cz sensor cover Ks water outlet drain C circulation Grz connection for the heating element K5 boiler ...

Page 6: ...ved Galmet Sp z o o Sp K 6 4 Technical specification 4 2 Scheme of the SGW S Vulcan 100 140 l wall mounted 1 Heating water outlet R3 4 2 Cold water for use inlet R3 4 3 Circulation R3 4 4 Hot water for use outlet R3 4 5 Heating water inlet R3 4 6 Sensor cover R3 8 ...

Page 7: ... exchanger capacity l 5 2 Demand tor central heating water m3 h 2 5 Efficiency 70 10 45 C l h 700 Heating power kW 29 Dimensions L height mm 990 1090 1240 Tank dimensions without insulation Ø 400 Tank dimensions with insulation mm 455 x 455 Soft polyurethane foam insulation mm 25 External housing metal jacket Connections Cold water hot water R 3 4 Circulation R 3 4 Heating water circuit supply ret...

Page 8: ...Installation and Operating Manual SGW S Vulcan All rights reserved Galmet Sp z o o Sp K 8 4 Technical specification 4 4 Scheme of the SGW S Vulcan 100 140 l free standing Magnesium anode Water drain ...

Page 9: ... All rights reserved Galmet Sp z o o Sp K Installation and Operating Manual SGW S Vulcan 9 4 Technical specification 4 5 Scheme of the SGW S Vulcan 200 l free standing 650 Water drain Magnesium anode ...

Page 10: ...ating water m3 h 2 5 2 6 Efficiency 70 10 45 C l h 700 950 Heating power kW 29 39 Dimensions A mm 140 190 B mm 60 C mm 40 D mm 100 E mm 120 L height mm 990 1090 1240 1130 Tank dimensions without insulation Ø 400 550 Tank dimensions with insulation mm 455 x 455 650 x 650 Soft polyurethane foam insulation mm 25 50 External housing metal jacket Connections Cold water hot water R 3 4 1 Circulation R 3...

Page 11: ...potentiometer plug must not be lengthened 2 A random change in polarity causes the acceleration of corrosion 3 It is recommended to use the socket 230V in a short distance from the tank 5 2 Troubleshooting LED CONTROL CAUSE METHOD OF REMOVAL ON green colour Anode CORREX working properly Full protection against corrosion OFF Lack of electricity Check the voltage 230V ON red colour Lack of water in ...

Page 12: ...liant with the following directives Pressure Equipment Directive PED 2014 68 UE The water heaters are intended for heating and storage of the DHW The wall thickness of the jackets and the bottoms as well as the material the exchangers were made of are listed below Type Diameter Ø Bottoms Material Jackets Material Material thickness Material thickness SGW S 100 400 2 5 S23JR 2 5 S25JR SGW S 120 400...

Page 13: ...uct fiche according to EU Regulation No 812 2013 7 1 SGW S Vulcan 1 EN Supplier s name or trade mark Galmet 2 EN Supplier s model identifier SGW S Vulcan 100 SGW S Vulcan 120 SGW S Vulcan 140 SGW S Vulcan 200 3 EN Energy efficiency class C D D C 4 EN Standing loss W 62 74 84 65 5 EN Storage volume L 101 113 127 194 ...

Page 14: ...Installation and Operating Manual SGW S Vulcan All rights reserved Galmet Sp z o o Sp K 14 Notes ...

Page 15: ...l of the service Seal of the service Seal of the service Seal of the service Name address of the owner Name address of the owner Name address of the owner Name address of the owner Owner s signature Owner s signature Owner s signature Owner s signature No Date of receiving Description of the repair Date of worksmanship Serviceman s signature ...

Page 16: ... 4 Type Type Type Type Factory No Factory No Factory No Factory No Date of sale Date of sale Date of sale Date of sale Seller s seal and signature Seller s seal and signature Seller s seal and signature Seller s seal and signature Magnesium anode replacement confirmation paid service Date and signature of an authorized person Date and signature of an authorized person Date and signature of an auth...

Reviews: