Gallagher Reader Module 8R or 4R (attached to the Controller 6000)

Connect the wires to the sockets as shown:

-

+

R1 Out

R1 In

C

1

2

3

C

4

5

6

R2 Out

R2 In

Gallagher Reader Module

Negative

Black

Positive

Red

Reserved

Orange

Reserved

Green

Reserved

Brown

CDXIV RX

Blue

CDXIV TX

White

Car

da

x IV R

eader 1

Negative

Black

Positive

Red

Reserved

Orange

Reserved

Green

Reserved

Brown

CDXIV RX

Blue

CDXIV TX

White

Car

da

x IV R

eader 2

Gallagher GBUS Universal Reader Interface (Gallagher GBUS URI)

Connect the wires to the sockets as shown in either of the following diagrams:

RL

Y 2 C

OM

RL

Y 2 NO

RL

Y 2 NC

DA

TA

 

0

DA

TA

 

1

OUT

 

1

OUT

 

2

COM

 

A

COM

 

B

TAMPER

GND

VOUT

GND

VIN

GND

Pin 15

Reader

Top Row

Pin 1

Gallagher GBUS URI

Positiv

e

Re

d

Neg

ativ

e

Black

Reser

ved

Or

ang

e

Reser

ved

Gr

een

Reser

ved

Br

own

CD

XIV TX

Whit

e

CD

XIV RX

Blue

Cardax IV Reader

RL

Y 2 C

OM

RL

Y 2 NO

RL

Y 2 NC

DA

TA

 

0

DA

TA

 

1

OUT

 

1

OUT

 

2

COM

 

A

COM

 

B

TAMPER

GND

VOUT

GND

VIN

GND

Pin 15

Reader

Top Row

Pin 1

Gallagher GBUS URI

Positiv

e

Re

d

Neg

ativ

e

Black

Reser

ved

Or

ang

e

Reser

ved

Gr

een

Reser

ved

Br

own

CD

XIV TX

Whit

e

CD

XIV RX

Blue

Cardax IV Reader

Summary of Contents for T20

Page 1: ...eads Mifare DESFire EV1 Mifare Plus Mifare Classic and 125 KHz cards The reader sends information to the Gallagher Controller and acts upon information sent from the Gallagher Controller The reader it...

Page 2: ...o operate over a supply voltage range of 9 16 Vdc measured at the reader terminals The operating current draw is dependent on the supply voltage at the reader For the Mifare reader at 12 Vdc the curre...

Page 3: ...42 4 x 0 4 mm2 Not twisted pairs 21 AWG 200 m 650 ft 150 m 500 ft The matching of wire sizes to equivalent wire gauges are only approximate Notes Shielded cable may reduce the obtainable cable length...

Page 4: ...hole for which the building cable will exit the mounting surface and the four corner fixing holes Ensure the centre hole allows the cable to run freely out through the mounting surface so that the rea...

Page 5: ...ons Positive Red Negative Black Reserved Orange Reserved Green Reserved Brown CDXIV TX White CDXIV RX Blue Cardax IV Reader 7 Fit the facia assembly into the base by clipping the small lip into the to...

Page 6: ...a piece of gaffer tape Stick the tab to the facia over the Gallagher logo and use it to pull the facia out of the base then remove the tape without leaving a mark Connections The Gallagher T20 Reader...

Page 7: ...te Cardax IV Reader 2 Gallagher GBUS Universal Reader Interface Gallagher GBUS URI Connect the wires to the sockets as shown in either of the following diagrams RLY 2 COM RLY 2 NO RLY 2 NC DATA 0 DATA...

Page 8: ...COM NO NO NO NO NC NC NC NC PF1 PE1 P1 0V VIN COMB 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 1 1 2 DETECTOR LED RS485 POWER IN J4 J3 J2 J1 0V 0V 0V 0V VOUT VOUT VOUT VOUT PA4 PA3 PA2 PA1 2 1...

Page 9: ...PA Positive Red Negative Black Reserved Orange Reserved Green Reserved Brown CDXIV TX White CDXIV RX Blue Cardax IV Reader Positive Red Negative Black Reserved Orange Reserved Green Reserved Brown CDX...

Page 10: ...utine maintenance Not applicable for this reader Cleaning This reader should only be cleaned with a clean lint free damp cloth Voltage 9 Vdc 16 Vdc Current at 12Vdc 82 mA standby Mifare reader 115 mA...

Page 11: ...n Note Document Code 3E3140 Edition 3 April 2013 Icons The Gallagher T20 Reader displays the following icons Arming Failed Arming Succeeded Armed Present Card Present Second Card Enter PIN Access Gran...

Page 12: ...V technician for help Industry Canada This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interfere...

Page 13: ...ting Dimensions 179 5 mm 7 07 inches 95 7 mm 3 77 inches 6G Screw 60 3 mm 2 37 inches 29 1 mm 1 14 inches 60 3 mm 2 37 inches 83 3 mm 2 78 inches Flush Box Screw Cable Exit 125 card read area Mifare c...

Reviews: