3E4465 Gallagher HBUS 8 Port Hub Installation Note | Edition 4 | January 2021
Copyright © Gallagher Group Limited
Page 8
6
Technical specifications
Operating voltage (Vin):
13.6 Vdc + 15%
Operating current at 13.6 Volts:
20 mA
Available current from each HBUS
outgoing port:
1 x 4A resettable fuse supplying all output power ports
Temperature range:
-10 °C to 50 °C (14 °F to 122 °F)
0 °C to 49 °C (32 °F to 120 °F)
(Independently verified)
(UL certified)
Humidity:
95% non-condensing
85% non-condensing
(Independently verified)
(UL certified)
Power and Comms cable length:
Depends on power requirements of end devices
Comms only cable length:
up to 500m
Cable length using Gallagher HBUS Cable:
up to 500m
Height:
Width:
Depth:
30 mm (1.2 in) with connectors
87 mm (3.4 in)
88 mm (3.5 in)
7
Unit dimensions
IMPORTANT