3E4465 Gallagher HBUS 8 Port Hub Installation Note | Edition 4 | January 2021
Copyright © Gallagher Group Limited
Page 4
1
Introduction
The Gallagher HBUS 8 Port Hub provides installers with the flexibility to re-use existing wiring on site,
allowing combinations of star/home run and daisy chain wiring to be used when connecting HBUS devices
back to a Gallagher Controller 6000. It utilises a FPGA (field programmable gate array) to allow for the
star wiring of devices. The HBUS 8 Port Hub is not a monitored device and therefore is transparent to the
Controller.
Note:
UL have evaluated the 8 Port Hub with readers and alarm terminals only. Tension sensor and
Fence Controller equipment have not been evaluated as they are not subject to the UL294 listing.
2
Before you begin
2.1
Shipment contents
Check the shipment contains the following items:
•
1 x Gallagher HBUS 8 Port Hub
•
1 x Gallagher HBUS 8 Port Hub Installation Note (this note)
•
4 x 4G X 1/4" pan pozi screws
2.2
Power supply
The Gallagher HBUS 8 Port Hub requires a 13.6 Vdc + 15% power supply. This is connected
through the 2 pin connector labelled
Vin
. The 2 pins are labelled
-
and
+
. The terminals VOUT
and GND provide a 13.6 Vdc + 15% output suitable for HBUS connections, rated at 4A total from
all outputs.
2.3
Cabling
The end devices on the HBUS cable should be terminated using 120
Ω
resistance. Termination is
already included at the HBUS Module out ports, (i.e. each HBUS out port is permanently
terminated at the module).