Extended I/O of the DMC-40x0 Controller
The DMC-40x0 controller offers 32 extended TTL I/O points which can be configured as inputs or outputs in 8 bit
increments. Configuration is accomplished with command CO – see Extended I/O of the DMC-40x0 Controller
The I/O points are accessed through the 44 pin D-Sub connector labeled EXTENDED I/O. See the A5 – CMB-
41012 (-C012) section in the Appendix for a complete pin out of the Extended I/O.
Electrical Specifications (3.3V – Standard)
Inputs
Max Input Voltage
3.4 VDC
Guarantee High Voltage
2.0 VDC
Guarantee Low Voltage
0.8 VDC
Inputs are internally pulled up to 3.3V through a 4.7k
Ω
resistor
Outputs
Sink/Source
4mA per output
Electrical Specifications (5V – Option)
Inputs
Max Input Voltage
5.25 VDC
Guarantee High Voltage
2.0 VDC
Guarantee Low Voltage
0.8 VDC
Inputs are internally pulled up to 5V through a 4.7k
Ω
resistor
Outputs
Sink/Source
20mA
DMC-40x0 User Manual
Chapter 3 Connecting Hardware
•
40
Summary of Contents for DMC-4040
Page 54: ...Chapter 3 Connecting Hardware 45 DMC 40x0 User Manual...
Page 55: ...DMC 40x0 User Manual Chapter 3 Connecting Hardware 46...
Page 56: ...Chapter 3 Connecting Hardware 47 DMC 40x0 User Manual...
Page 73: ...Figure 4 1 GalilTools DMC 40x0 User Manual Chapter 4 Software Tools and Communication 64...
Page 185: ...THIS PAGE LEFT BLANK INTENTIONALLY DMC 40x0 User Manual Chapter 7 Application Programming 176...
Page 205: ...THIS PAGE LEFT BLANK INTENTIONALLY DMC 40x0 User Manual Chapter 10 Theory of Operation 196...
Page 222: ...Step 2 Remove ICM s Appendices 213 DMC 40x0 User Manual...
Page 232: ...DMC 4080 Steps 4 and 5 Step 4 Replace ICM s Appendices 223 DMC 40x0 User Manual...