180
●
OT
DMC-40x0 Command Reference
OT
FUNCTION:
Off on encoder failure time
DESCRIPTION:
Sets the time in samples (milliseconds for TM1000) that the controller will wait for motion after
the OV threshold has been exceeded. The controller can detect a failure on either or both
channels of the encoder. This is accomplished by checking on whether motion of at least 4
counts is detected whenever the torque exceeds a preset level (OV) for a specified time (OT).
Note that for this function to work properly it is necessary to have a non-zero value for KI.
ARGUMENTS:
OTn,n,n,n,n,n,n,n where
n is the number of samples between 2 and 32000
? returns the last value set
USAGE: DEFAULTS:
While Moving
Yes
Default Value
30
In a Program
Yes
Default Format
5.0
Command Line
Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_OTn contains the OT value for the specified axis.
RELATED COMMANDS:
Off on encoder failure
Off on encoder failure voltage
EXAMPLES:
OTX=10
Set time to 10 milliseconds (TM1000)
OVX=5
Set voltage to 5
OAX=1
Enable encoder detection feature
Summary of Contents for DMC-40x0 Series
Page 2: ......
Page 4: ......
Page 10: ...vi i Table of Contents DMC 40x0 Command Reference This Page is Left Blank Intentionally ...