![Galil Motion Control DMC-40x0 Series Command Reference Manual Download Page 140](http://html1.mh-extra.com/html/galil-motion-control/dmc-40x0-series/dmc-40x0-series_command-reference-manual_558773140.webp)
130
●
IN
DMC-40x0 Command Reference
IN
FUNCTION:
Input Variable
DESCRIPTION:
The IN command allows a variable to be input from a keyboard. When the IN command is
executed in a program, the prompt message is displayed. The operator then enters the variable
value followed by a carriage return. The entered value is assigned to the specified variable
name.
The IN command holds up execution of following commands in a program until a carriage return
or semicolon is detected. If no value is given prior to a semicolon or carriage return, the
previous variable value is kept. Input Interrupts, Error Interrupts and Limit Switch Interrupts
will still be active.
The IN command may only be used in thread 0.
ARGUMENTS:
IN "m",n
where
m is prompt message
n is the variable name
The total number of characters for n and m must be less than 80 characters.
Note: Do not include a space between the comma at the end of the input message and the variable
name.
USAGE: DEFAULTS:
While Moving
Yes
Default Value
-----
In a Program
Yes
Default Format
Position Format
Command Line
No
Controller Usage
ALL CONTROLLERS
EXAMPLES:
Operator specifies length of material to be cut in inches and speed in inches/sec (2 pitch lead screw, 2000
counts/rev encoder).
#A
;
'Program A
IN
"Enter Speed(in/sec)"
,V1
;
'Prompt operator for speed
IN
"Enter Length(in)"
,V2
;
'Prompt for length
V3=V1*4000
;
'Convert units to counts/sec
V4=V2*4000
;
'Convert units to counts
SP
V3
;
'Speed command
PR
V4
;
'Position command
BG
A
;
'Begin motion
AM
A
;
'Wait for motion complete
MG
"MOVE DONE"
;
'Print Message
EN
;
'End Program