![Galil Motion Control DMC-40x0 Series Command Reference Manual Download Page 131](http://html1.mh-extra.com/html/galil-motion-control/dmc-40x0-series/dmc-40x0-series_command-reference-manual_558773131.webp)
DMC-40x0 Command Reference
IA • 121
IA
FUNCTION:
IP Address
DESCRIPTION:
The IA command assigns the controller with an IP address.
The IA command may also be used to specify the time out value. This is only applicable when
using the TCP/IP protocol.
The IA command can only be used via RS-232. Since it assigns an IP address to the controller,
communication with the controller via internet cannot be accomplished until after the address
has been assigned.
ARGUMENTS:
IA ip0,ip1,ip2, ip3
or
IA n
or
IA<t
where
ip0, ip1, ip2, ip3 are 1 byte numbers separated by commas and represent the individual fields of
the IP address.
n is the IP address for the controller which is specified as an integer representing the signed 32 bit
number (two’s complement).
<t specifies the time in update samples between TCP retries. 1< = t < = 2,147,483,647 up to 5
retries occur. (TCP/IP connection only)
>u specifies the multicast IP address where u is an integer between 0 and 63. (UDP/IP connection
only)
IA? will return the IP address of the controller
USAGE: DEFAULTS:
While Moving
No
Default Value
n = 0, t=250
In a Program
Yes
Default Format
Command Line
Yes
Controller Usage
ALL CONTROLLERS
OPERAND USAGE:
_IA0
contains the IP address representing a 32 bit signed number (Two’s complement)
_IA1
contains the value for t (retry time)
_IA2
contains the number of available handles
_IA3
contains the number of the handle using this operand where the number is 0 to 5. 0
represents handle A, 1 handle B, etc.
_IA4
contains the number of the handle that lost communication last, contains A-1 on reset to
indicate no handles lost
_IA5
returns autonegotiation Ethernet speed. Returns 10 for 10-Base T and returns 100 for
100-Base T, it will return -1 if there is no physical link
RELATED COMMANDS:
Handle
EXAMPLES:
IA 151,12,53,89
Assigns the controller with the address 151.12.53.89
IA 2534159705
Assigns the controller with the address 151.12.53.89
IA < 500
Sets the timeout value to 500msec