MAINTENANCE
MAINTENANCE PROCEDURE
4-57
CLEAN FRESH/RECIRC AIR FILTERS OF AIR CONDITIONER (ONLY FOR MACHINES
EQUIPPED WITH AIR CONDITIONER)
4
WARNING
If compressed air is used, there is danger that dirt may fly and cause personal injury.
Always wear safety glasses, dust mask, and other protective equipment.
NOTICE
As a guideline, the filters should be cleaned every 500 hours, but on dusty jobsites, clean the filters more
frequently.
REMARK
If the filter becomes clogged, the air flow will be reduced, and there will be an abnormal noise from the air condi-
tioner unit.
CLEAN INTERNAL AIR FILTER
1. Remove wing bolts (1) from the inspection window at the bot-
tom rear left on the inside of the operator's cab, then take out
the recirculated air filter.
2. Clean the filter with compressed air. If there is oil on the filter,
or if the filter is extremely dirty, wash it in a neutral agent.
After rinsing it in water, dry it thoroughly before using it again.
If the clogging of the filter cannot be removed by blowing with
air or washing in water, replace the filter with a new part.
CLEAN EXTERNAL AIR FILTER
1. Pull up the lock release lever under the door release lever (1)
to release the lock.
2. Open cover (2) at the bottom left of the operator's cab by
hand, pull out filter case (3) from the inside, then remove the
filter.
Summary of Contents for PC600-7
Page 2: ...1 1 FOREWORD 11 ...
Page 4: ...FOREWORD FOREWORD 1 3 ...
Page 5: ...FOREWORD FOREWORD 1 4 ...
Page 18: ...2 1 SAFETY 12 ...
Page 22: ...SAFETY SAFETY LABELS 2 5 LOCATION OF SAFETY LABELS 2 ...
Page 28: ...SAFETY SAFETY LABELS 2 11 19 Jump start prohibited 09842 A0481 ...
Page 59: ...3 1 OPERATION 13 ...
Page 168: ...MACHINE OPERATIONS AND CONTROLS OPERATION 3 110 Boom operation Bucket operation ...
Page 211: ...4 1 MAINTENANCE 4 ...
Page 277: ...MAINTENANCE MAINTENANCE PROCEDURE 4 67 q Center frame A Important check points q Boom ...
Page 288: ...5 1 SPECIFICATIONS 15 ...
Page 291: ...6 1 ATTACHMENTS AND OPTIONS 16 ...
Page 299: ......