Some contact time references in the literature 

Subjects 

Speed 

Contact time 

 

Usain Bolt 

40 km/h 

83

 ±2 ms (100 m sprint)

 

 

Beginners (n=30) 

21 km/h 

140

 ±11 ms for sprinters

 

160

 ±13 ms for long distance runners 

 

Cunninghal 2013 

Half marathon runners 
(n=283) 

18 km/h 

183

 ±16 ms for mid and front foot 

runner

 

200

 ±21.3 ms for rear foot runners

 

Hasegawa 2007 

Beginner (n=30) 

15 km/h 

180

 ±16 ms for sprinters

 

250

 ±20 ms for long distance runners

 

Cunninghal 2013 

Ultra-Marathon trail 
runners(n=18) 

10 km/h 

249

 ±16 ms at the start of the race

 

252

 ±17 ms after 3h in the race

 

Morin 2011 

Beginners (n=210) 

9 km/h 

236

 ± 26 ms

 

Bredeweg 2013 

 

6. Limited Warranty & Support Policy  

 

Warranty:  

Gait Up offers 12 months parts and labour on Physilog

®

 starting from the date of delivery. If within 

one year from the date of delivery to the customer the equipment does not comply with the foregoing 
l

imited warranty, Gait Up will at Gait Up’s option, repair, replace or refund the purchase price of the 

defective equipment free of charge to the customer. Customers requesting repair, replacement or 
refund are required to ship, the Physilog

®

 to Gait Up. As a condition of this warranty, customers must 

contact Gait Up’s customer service for instructions on and approval of shipment prior to returning 
any defective Physilog

®

. The warranty shall not apply to any product or component thereof which 

has  been  repaired  or  altered  by  anyone  other  than  Gait  Up  in  any  manner  so  as,  in  Gait  Up’s 
judgement, to affect its service ability, or any product been subject to alteration, accident, misuse, 
abuse, neglect or abnormal wear. Gait up warrants solely to the original purchaser (customer). Only 
the  terms  expressed  in  this  warranty  shall  apply  and  no  distributor,  corporation  or  individual  is 
authorized to amend, modify or extend this warranty in any way.  

GaitUp shall have no liability for any consequential, incidental or special damages by reason of any 
act or omission or arising out of or in connection with the equipment or its rental, delivery, installation, 
maintenance,  operation,  performance  or  use,  including  without  limitation  any  loss  of  use,  lost 
revenue, lost profits or a cost associated with downtime. The obligations contained in this paragraph 
continue beyond the term of this limited warranty.  

Physilog

®

 and Gait Analysis Software are not considered as proper Medical Devices, since they do 

not support directly diagnosis, but they provide data which have to be analysed and approved by 
medical doctors for them to make their diagnosis. Reclamations regarding medical devices will not 
be considered.  

Support Policy:  

Support does not include:  

 

support for 3rd party hardware, software, mailing lists or web content  

 

writing or debugging customer applications and deployments  

 

detailed explanations of the engineering principles behind our software and hardware 

 

support for systemic problems beyond the scope of the actual Physilog® and existing systems 
software (IT issues, computer operation)  

 

support for customers whose conduct fails to meet professional standards  

Summary of Contents for PhysiRun Lab

Page 1: ...EPFL Innovation Park Bat C CH 1015 Lausanne www gaitup com TVA CHE 145 136 760 User guide PhysiRun Lab v1 1 1 Date 06 05 2019 Copyright 2018 2019 All Rights Reserved Gait Up SA CH 1015 Switzerland 1...

Page 2: ...iRun Lab for running analysis The software allows to highlight a multitude of biomechanical parameters to observe the running technique with the GaitUp sensors Physilog 5 The Physilog 5 started from a...

Page 3: ...guration 4 2 3 Time setting 5 2 4 Fix the Sensors 5 2 5 Protocol 6 3 How to do a measurement with Physilog 5 6 3 1 Start measure from the watch 6 3 2 Start a measure from the Physilog 5 7 4 PhysiRun L...

Page 4: ...rement or by 3 rapid red blinks when you want to start a new measurement If the Physilog 5 is completely discharged charge at least 30 minutes before using Battery life estimation is available when yo...

Page 5: ...ctly set your files are saved in a folder with the measurement date If you start the sensors from the watch or the application the time is automatically updated and you thus don t need to follow the i...

Page 6: ...s BIN are saved in the sensor memory 8Go A file contains the raw data Below you can check the name description 3 1 Start measure from the watch A measurement from the watch allows to start and stop th...

Page 7: ...e started directly from the Physilog 5 Material required 2 Physilog 5 To start the measure hold the button for 3 seconds on each sensor Check that there is a green blinking on your two sensors after r...

Page 8: ...t on your computer Save your file in the same folder on your computer 1LF091 BIN for example If the time is correctly configured you file is saved in a folder at the date of measurement for example 18...

Page 9: ...different result files you want to obtain pdf excel file csv file In the PDF format there are three pages Excel and csv format give the cycle by cycle calculation for each parameter To generate these...

Page 10: ...llowing instructions carefully For sensors calibration move the gray window to have a part of static period and some running cycles see picture below To move the window click on the top bar You can al...

Page 11: ...s no space or special character allowed PDF excel and csv will have the same name The language for the PDF report can be selected from available translations in the list To obtain the third page of th...

Page 12: ...5 to measure water sport activities without additional waterproofing Storage Store in a cool 0 C 30 C and dry place The provided box is the perfect place for your sensor Cleaning Sensors can be cleane...

Page 13: ...log when the temperature is outside of the range of 0 to 45 C Physilog 5 should be charged through USB connection with a computer An external charger may be used note that no charger is provided by Ga...

Page 14: ...ks Error 2 3 rapid red blinks Error 3 4 rapid red blinks Error 4 5 rapid red blinks Error 5 6 rapid red blinks Error 6 Error type Error type How to solve the issue Error 1 Disconnect and replug the Ph...

Page 15: ...apply to any product or component thereof which has been repaired or altered by anyone other than Gait Up in any manner so as in Gait Up s judgement to affect its service ability or any product been s...

Page 16: ...ice may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operations a 5 When the device is so small or for such us...

Page 17: ...t us at EPFL Innov Park C CH 1015 Lausanne tel 41 21 633 7527 mail contact gaitup com web www gaitup com Document Version Changes Responsible Date 1 0 0 First public version Jules Gellaerts 29 11 18 1...

Reviews: