Installation
IDR1000A DC Remote Desk Set Use and Installation Manual
02/12 12
Equipment Required
Test Equipment
RF service monitor
AC voltmeter with dB ranges for measuring audio levels
#1 Phillips screwdriver
1/8-inch flat blade screwdriver
Documentation
base station’s tone remote adapter manual
these installation instructions
Cable Installation Safety Considerations
Interconnecting, communications, and Class 2 dc power cables should be separated from electrical light
or other Class 1 circuits by at least 2 inches. The exception is where Class 1 wiring or power circuits are
run in a raceway, or are metal-sheathed or metal-clad, or are permanently separately from the conductors
of the other circuitry by a continuous and firmly fixed nonconductor such as porcelain tubes or flexible
tubing in addition to the insulation on the wire. Communications cables and in-building wiring should be
listed and marked for the purpose according to NEC Article 800.
Telephone Line Lightning and Over-voltage Protection
For maximum surge and lightning protection, building primary (over-voltage) protectors should be
installed at the point where the telephone lines enter the radio equipment building. Primary protectors
are usually required by local codes and should be provided by your leased line provider.
The IDR1000A DC Remote Desk Set has an over-current phone line fuse (F2) which protects against
occasional extreme fault conditions that may get past the primary protectors. An example of such a fault
condition is a power line cross. If the fuse requires replacement, replace F2 with the same type
Bussmann C515S-1.25 A fuse.
Summary of Contents for IDR1000A
Page 27: ...23 02 12 Main Circuit Board...
Page 28: ...Main Circuit Board IDR1000A DC Remote Desk Set User and Installation Manual 24...
Page 29: ...25 02 12 Schematics...
Page 36: ...Schematics IDR1000A DC Remote Desk Set User and Installation Manual 32 Notes...
Page 38: ...Notes IDR1000A DC Remote Desk Set User and Installation Manual 34...