Pub. 42004-470G
Clean Phone
®
VoIP Telephones
Page 8 of 15
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-470G.docx
05/19
Model 295-702W
The mounting and wiring instructions are as follows:
1.
Remove the front panel from the back box.
2.
If using Power-over-Ethernet, with no optional inputs or outputs:
place the bushing around the
Ethernet cable so that it is located approximately 5 inches from the end of the cable. Snap the
bushing closed and insert it into the double
D
hole in the back box (see Figure 4 and Figure 8).
3.
If using local power or optional inputs or outputs:
route the cables through the
D
hole in the bottom
of the back box (see Figure 4 and Figure 8).
4.
Position the back-box so that it is level on the wall in the desired location.
5.
Use the back box as a template to drill the lower right and upper left corners holes and secure the
back box with screws.
6.
Drill the remaining holes and completely secure the box with the remaining screws.
7.
Plug in the Ethernet cable and connect all other optional cables (see the Field Wiring section).
8.
Perform the initial programming of the telephone (see the Programming section).
9.
Align the front panel of the Clean Phone
®
with the four slots in the back box.
10.
Press the panel in firmly and push it downward to seat it in the slots.
N
OTE
:
The Model 295-702W VoIP Telephone is designed for general wipe down cleaning and to prevent
collection (internally and externally) of particulate matter.
Figure 8. Mounting the Model 295-702W