![GAI-Tronics 370-901 Manual Download Page 14](http://html1.mh-extra.com/html/gai-tronics/370-901/370-901_manual_3192164014.webp)
Pub. 42004-525A
Model 370-901 SP2 to Page/Party
®
Bridge
Page 12 of 16
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-525A.docx
08/18
Channel and Redundant Channel Status
The
C
HANNEL
S
TATUS
and
R
EDUNDANT
C
HANNEL
S
TATUS
screens provide the following information
for each channel:
Active
—
Y
ES
or
N
O
Level to IP (mV)
—audio signal level to SP2 system in millivolts
Level to Analog (mV)
—signal level to Page/Party
®
system in millivolts
VOX Input Level (mV)
—signal level for voice activation in millivolts
Isolated
—
Y
ES
or
N
O
VLC Active
—
Y
ES
or
N
O
Stream Count
—number of simultaneous audio streams passing through the bridge
Operation
The SP2 to Page/Party
®
Bridge provides real-time audio communication between SP2 and Page/Party
®
systems. No user interaction is required after the bridge is installed and configured. The bridge is
equipped with eight status LEDs to provide indication of the bridge’s operation. A global disable button
is also provided to completely isolate the connected SP2 and Page/Party
®
systems.
Global Disable
Press and release the
G
LOBAL
D
IS
press-button switch (
S1
) to completely isolate the SP2 and Page/Party
®
systems from each other. The switch operates as a toggle. Press the button to isolate the two systems.
Press the button again to enable bridging the two systems. The switch state is logically tied to the setting
configured in the GUDA software.