Interface Configuration 

The 

C

ONFIGURATION

 screen appears with the 

I

NTERFACE

 properties shown: 

 

Configure the following properties for the bridge’s NIC: 

 

Interface Name

—name for the SP2 to 

Page/Party

®

 Bridge 

 

Address Mode

—select Static or DHCP 

 

Control TTL

—time to live for control 

packets 

 

Control Port

—memory address of the 

control service 

 

IP Address

—client network address, 

leave blank for DHCP clients 

 

Netmask

—subnet mask,  leave blank for 

DHCP clients 

 

Default Gateway

—IP address of router 

to other networks, leave blank for DHCP 
clients 

 

Primary DNS

—primary DNS server, 

leave blank for DHCP clients 

 

Secondary DNS

—secondary DNS 

server, leave blank for DHCP clients 

 

NTP Server

—network time protocol 

server IP address, leave blank for DHCP 
clients 

 

Allow HW Disable

Yes

 or 

No

 

 

Interface Mode

Standalone

Primary

, or 

Backup

 

 

Redundancy ID

—unique name for 

redundant bridges—must be identical on 
the primary and secondary bridges 
configured for redundancy

 

Summary of Contents for 370-901

Page 1: ...losure 2 Mount the Enclosure 3 Field Terminations 3 Earth Ground 3 Ethernet TB1 4 Page Party 33 Ohm Audio Connections P2 5 60029 Series Page Party System Cable 5 Channel Isolation Inputs P3 6 Contact...

Page 2: ...A 19605 USA 610 777 1374 800 492 1212 Fax 610 796 5954 VISIT WWW GAI TRONICS COM FOR PRODUCT LITERATURE AND MANUALS GUDA Software Updates 15 Troubleshooting 15 Service and Spare Parts 16 Specification...

Page 3: ...n may only be used in connection with the operation of your GAI TRONICS product or system This manual may not be disclosed in any form in whole or in part directly or indirectly to any third party Gen...

Page 4: ...Adhere to all warnings on the unit and in the operating instructions Attachments Attachments not recommended by the product manufacturer should not be used as they may cause hazards Open the Enclosure...

Page 5: ...unting holes are 0 280 inches in diameter 4 Install conduit using Myers ST 4 1 25 inch Scru Tite hubs or equivalent Reducers must be used for smaller conduit sizes to ensure proper contact with the su...

Page 6: ...Install ferrules onto the wire ends 3 Connect the Ethernet cable to the 8 position pluggable terminal block TB1 see Figure 4 and Table 1 4 Connect the pluggable terminal block to terminal block recept...

Page 7: ...y SystemCable Page Party stations should be connected using GAI TRONICS 60029 Series system cable Refer to Table 3 for the Page Party system cable color codes Table 3 Page Party 60029 Series System Ca...

Page 8: ...re terminated at terminal block P4 P4 is an 18 position terminal block Three position pluggable terminal blocks are used for each output to simplify the connection of the outputs 1 Pull the cable s fo...

Page 9: ...es onto the wire ends 3 Connect the line and neutral conductors to the pluggable terminal block see Figure 4 and Table 6 4 Connect the pluggable terminal block to terminal block P1 Close the Enclosure...

Page 10: ...m the GUDA screen 4 Double click the SP2 TO PAGE PARTY BRIDGE to configure from the list of devices displayed Bridges that are not configured appear as follows 5 Enter the default user name shown and...

Page 11: ...emory address of the control service IP Address client network address leave blank for DHCP clients Netmask subnet mask leave blank for DHCP clients Default Gateway IP address of router to other netwo...

Page 12: ...Multicast Port multicast service port address for the audio channel Multicast TTL time to live for multicast network traffic Analog VOX Threshold mV signal voltage where the VOX circuit picks up 1 10...

Page 13: ...TATUS screen provides the following information Firmware Version bridge firmware version IP Address IP address currently assigned to the bridge MAC Address MAC address of the bridge Network Data Rate...

Page 14: ...streams passing through the bridge Operation The SP2 to Page Party Bridge provides real time audio communication between SP2 and Page Party systems No user interaction is required after the bridge is...

Page 15: ...s are not disconnected with a pause in conversation Table 7 System Status LEDs LED State Description PL1 On activity on party line one PL2 On activity on party line two PL3 On activity on party line t...

Page 16: ...tandard Windows OPEN dialog box Browse to the desired folder and open the desired firmware file and then click BEGIN UPDATE in the DEVICE FIRMWARE UPDATE box to update the devices firmware Enable Disa...

Page 17: ...guration to take effect GUDA Software Updates Click OK to install updates to the GUDA software when the UPDATE AVAILABLE box appears after launching the GUDA application Updates are made available for...

Page 18: ...50 60 Hz Ethernet 100Base TX 1000Base T with IGMP Output relay contact rating 1 A 30 V dc Channel isolation inputs dry contact Ethernet Cable Category 5 or better Speed 100 Mbps minimum Maximum stati...

Page 19: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: