background image

Pub. 42004-442D 

Models 10959-903 and 10959-904 Wall-Mount Audio Messenger Interface 

Page 14 of 17 

P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-442D.docx 
10/18 

LCD Display during Operation 

The LCD uses various symbols to indicate AMI activity: 

 

The VU meter indicates the volume of a page playing. 

 

 

Mute indicates the page audio is muted. 

 

 

Progress bar indicates remaining time for the party line connection timeout. 

 

 

Telephone handset indicates the AMI unit is being accessed via a telephone connection. 

 

 

Microphone indicates a page from the auxiliary jack. 

 

 

Off hook indicates that a digital input designated as party line off hook is active. 

 

 

Right/left arrows indicate transmit and receive activity on the auxiliary jack or external RS-485. 

 

 

Text display (scrolling) displays current system status, such as the name of the current message 
playing, telephone connection status, and party connection status. 

 

Rotating slash, when visible, indicates the AMI has a lower priority message pending, ready to be 
played. 

 

 

 

MIN

MAX

MAX

MIN

MID

Summary of Contents for 10959-903

Page 1: ...tion 2 Radio Operation 3 Page Party Operation Model 10959 904 Only 3 Installation 4 Mounting 4 Field Wiring 5 Audio Output 5 Control Output 6 Telephone Line 7 ACC2500 Audio Control Center Desk Set 7 P...

Page 2: ...at Initial Power Up 13 LCD Display during Operation 14 Push Button Operation 15 Stop Message 15 Play Message 15 Firmware Update 15 Reset AMI 15 Return 15 Maintenance 16 Replacement Parts 16 Specificat...

Page 3: ...Messenger Interfaces are capable of broadcasting up to 125 pre recorded tone speech messages and live voice announcements They are designed to communicate with GAI Tronics Model ACC2500 Audio Control...

Page 4: ...ns based on the time of day Events can be scheduled to occur at any interval hourly daily weekly and monthly etc Scheduled events are configured using the ACT software LiveVoiceMessages The AMI can br...

Page 5: ...ne output Mixed Mode Records a page delivers it to the page line output and holds the party line open following the page Live Page Mode Delivers a live voice page not pre recorded to the page line out...

Page 6: ...To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord DANGER ATTENTION DANGER Pour r duire le risque d incendie utiliser uniquement des conducteurs de t l communications...

Page 7: ...shing the hinge pins on the front cover into the rear enclosure until a click is heard 4 Re install the cable connections between the front cover and the rear enclosure 5 Rotate the front cover to clo...

Page 8: ...no connection AUDBUS1 L2 TB3 6 PGND TB3 7 no connection RS485 INT GND TB3 8 no connection RS485 INT TB3 9 RS485 INT TB3 10 Control Output Terminal block TB4 labeled SYSTEM is located on the terminati...

Page 9: ...rDeskSet The Model ACC2500 Desk Set connection requires a No 12612 002 Interface and two modular cables included with the AMI Connect an 8 conductor Cat 5 Ethernet cable customer provided from the No...

Page 10: ...AMI Table 4 Input Power Connection Termination PCBA Label Internal Terminal Pin Out Function or ACT Description TB6 1 positive terminal of external power supply black wire with white stripe from powe...

Page 11: ...to the left Figure 4 AMI open with connections adjustments and PCBAs labeled 600 Ohm Line Termination Jumper Setting Terminate the 600 ohm audio lines with 600 ohms for impedance matching Use jumper P...

Page 12: ...om party line Adjust the party sidetone potentiometer R30 PageLineLevels Model 10959 904Only Two potentiometers on the Page Party Interface PCBA adjust the page line audio levels Volume level to the p...

Page 13: ...at is pre programmed with the 10959 903 or 10959 904 product configuration to retrieve configurations and play audio messages Please refer to the ACT software online help for specific instructions Sys...

Page 14: ...e play mode and repeat interval Event Scheduling Use the event scheduling feature to set up messages to automatically play at certain dates and times Set the following parameters when scheduling event...

Page 15: ...MI operates based on system inputs and outputs or by manual operation after the CompactFlash has been programmed and installed in the unit LCD Display at Initial Power Up The AMI completes a self diag...

Page 16: ...on timeout Telephone handset indicates the AMI unit is being accessed via a telephone connection Microphone indicates a page from the auxiliary jack Off hook indicates that a digital input designated...

Page 17: ...scroll to the PLAY item 3 Press ENTER PB4 to enter the PLAY item 4 Press SELECT PB3 to scroll to the message 5 Press ENTER PB4 to play the selected message FirmwareUpdate This menu item facilitates u...

Page 18: ...ovided with AMI Voltage input 120 V ac Voltage output 12 V dc Current 1 A maximum Audio Speech capacity 500 minutes with 512 Mb CompactFlash card Frequency response 250 6500 Hz 0 3 dB ref to 1 kHz Dis...

Page 19: ...7 of 17 P Standard IOMs Current Release 42004 Instr Manuals 42004 442D docx 10 18 Environmental Temperature range 32 F to 122 F 0 C to 50 C FCC Information Complies with CFR47 Part 15 Class A Approval...

Page 20: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: