background image

Pub.  42006-011C

GAI-Tronics Corporation  P.O. Box 1060, Reading, PA  19607-1060  USA

610-777-1374  

n

  800-492-1212  

n

  Fax:  610-775-6540

G A I - T R O N I C S   C O R P O R A T I O N

Field Maintenance Bulletin

Handset/Cord Repair Procedure

Part# 10108-007, 10108-008 and 10108-009

F

OR 

M

ODELS 

780 

AND 

7805 D

IV

. 1 H

AZARDOUS 

A

REA 

S

TATIONS

Confidentiality Notice

This manual is provided solely as an operational, installation, and maintenance guide and contains sensitive
business and technical information which is confidential and proprietary to GAI-Tronics.  GAI-Tronics
retains all intellectual property and other rights in or to the information contained herein, and such
information may only be used in connection with the operation of your GAI-Tronics product or system.
This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.

Tools Required

 

7/16-inch hex socket or combination wrench

 

Phillips screwdriver

 

Pipe wrench or channel lock pliers

 

Hammer

 

Nailset or hardened 1/8-inch diameter rod, approximately 4-inches long

 

Torque wrench

Liability Disclaimer

Notice:  

Follow all the steps in the procedure outlined below to ensure personnel safety, to avoid

equipment damage, and to maintain agency approvals.

Procedure

WARNING

  Disconnect power before making any repairs to a hazardous area station.

Note:

  The internal outer edge of the front cover is machined.  Take precautions to ensure that the finish is

preserved.  If damaged, the explosion-proof integrity can be lost.

1. 

 

Turn off power.

2. 

 

Remove the 14 bolts from the cover using a socket or a combination wrench.

3. 

 

Lift off the cover, and disconnect the flat ribbon cable.

4. 

 

Remove the 4 screws which hold the amplifier assembly to the cover.

Reviews: