2.3 Operating principle
The appliance features one-hand operation. That is
to say, the ignition is activated when the control
knob is pressed briefly.
After igniting, keep the control knob pressed for
around 5-8 seconds more because the heat sensor
that opens the gas channel has to warm up first.
The burner has a
thermal protection device
that
prevents unburned gas from escaping in the open
position.
The
total rated thermal load
amounts to:
17 000 BTU (5.0 kW) referred to Hs* (gross calorific
value)
15 300 BTU (4.5 kW) referred to Hi (calorific value)
The specified rated load is defined by installation
of the fixed nozzles.
The gas hob is converted to a
different gas type
by nozzle replacement (full and low-burning
nozzles) (see nozzle table).
The
symbols on the control
panel mean:
0
Off
Outer flame ring off
Low position of inner flame ring
Outer flame ring off
High position of inner flame ring
Low position of outer flame ring
High position of inner flame ring
High position of outer and inner flame rings
The flame is infinitely variable between high and
low-setting.
Maintenance Instructions
– Keep appliance area clean and free from
combustible materials, gasoline and other
inflammable vapors and liquids.
– Do not obstruct the flow of combustion and
ventilation air.
– Visually check burner flames with this pictorial
representation (see figure 4).
8
Fig. 4
Off
Level 1
Low
Level 2
Level 3
Level 4
High