Countertop Requirements
9
WARNING
To reduce the risk of ignition of surrounding
combustible materials, install at least 1" (25 mm)
from both sidewalls and at least 2" (50 mm) from
the rear wall.
The countertop must be level and horizontal. The
stability of the countertop must be maintained after the
cut-out has been made.
Technical Data
Total connected load electric: 0.8 VA
Installation Procedure
Installation Procedure
Prepare Installation Space
Prepare Installation Space
Create the cut-out in the countertop for one or several
Vario appliances according to the installation diagram.
The angle of of the cut surface to the countertop must
be 90°.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat-resistant manner.
Some solid surface countertops require special
installations. For example, heat reflective tape and
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to
your countertop.
Observe minimum distance between appliance
underside and furniture parts of
3
/
8
" (10 mm).
When installing multiple Vario appliances:
Take into
account space requirement for VV 200 connection strip
between the appliances. Appliances can also be
installed in individual cut-outs, bearing in mind a
minimum distance between the appliances of 1
9
/
16
"
(40 mm).
Install Appliance
9
WARNING
Before you plug in an electrical cord or turn on
power supply, make sure all controls are in the
OFF position.
1
Make a mark exactly in the center of the cut-out.
Fasten the short mounting rail to the front and the
long mounting rail to the rear edge of the cut-out.
The leading edges of the mounting rails must lie
upon the worktop. The center marking of the
mounting rails must correspond precisely with the
center marking of the cut-out.
Gas
Natural Gas
LPG (Propane)
Pressure
6" water col-
umn (1.5 kPa)
10" water col-
umn (2.5 kPa)
A-burner full burn
94
74
A-burner low burn
49
36
B-burner full burn
128
87
B-burner low burn
58
42
Total connected load
32,000 BTU/h
(9.4 kW)
32,000 BTU/h
(9.4 kW)
Total consumption
0.9 m³/h
680 g/h
[
¡
PP
¡
PP
PLQµPP
PLQµ
PP
PLQµ
PP
µ
PP
µ
PP
µ
PP
PLQµPP