en-us
Prepare installation space
8
3.6 Cabinet ventilation requirements
To assure that the appliance works correctly, the cooktop
MUST be sufficiently ventilated.
The ventilation in the lower section of the appliance re-
quires a sufficient supply of fresh air. Ensure that the cabi-
net is designed in a way that supports sufficient ventila-
tion. The following requirements must be fulfilled:
Notes
¡
A minimum clearance between the rear of the cabinet
and the kitchen wall, and between the surface of the
countertop and the upper area of the drawer.
¡
An opening at the top to the rear of the cabinet.
¡
If the minimum clearance of
13
/
16
" (20 mm) is not pro-
vided at the rear of the cabinet, you must create an
opening on the underside.
¡
If the inside of the cabinet is no wider than
29 ½" (750 mm), make cutouts in the side panels.
¡
If the appliance is installed in an island unit or another
installation that is not described here, you must ensure
that the cooktop is sufficiently ventilated.