en-us
Prepare installation space
6
¡
If the thickness of the countertop into which the cooktop
is installed does not comply with the specifications, rein-
force the worktop using a fire- and water-resistant mate-
rial until it reaches the minimum thickness. Otherwise,
sufficient stability cannot be assured.
¡
The countertop into which the cooktop is installed
should withstand loads of approx. 133 lbs (60 kg).
¡
Confirm the cooktop is level only after it has been in-
stalled.
3.1 Flush mounting
The cooktop can be mounted flush into the countertop.
Notes
¡
Any cutout work on the countertop must be performed
in a workshop according to the installation diagram.
¡
The cutout edge is visible on the surface after installa-
tion. Ensure that the cutout is made cleanly and pre-
cisely.
¡
Clean and degrease the cutout edges with a suitable
cleaning agent; follow the silicone manufacturer's pro-
cessing instructions.
Countertop material guide for flush mounting
Refer to the following chart to see if flush mounting is pos-
sible. All countertop materials must be temperature- and
water-resistant.
Countertop
material
Notes
Stone
Suitable for flush mounting
Plastic, such as
Corian®
Suitable for flush mounting
Solid wood
Only in consultation with the manufac-
turer of the countertop. Seal cutout
edges.
Tiled surfaces
Suitable for flush mounting
If necessary, raise the support surfaces
using heat and water resistant strips.
( ) = mm
(3.5 )
-0.5
²/16"
-0.02"
(3.5 )
-0.5
²/16"
-0.02"
Other
Only in consultation with the manufac-
turer of the countertop.
Particle board
Not suitable for flush mounting.
3.2 Cutout dimensions for 30" cooktops
Refer to these measurements for the models stated here.
¡
CX482611
¡
CX482612
3.3 Cutout dimensions for flush mounted 30"
cooktops
Refer to these measurements for the models stated here.
¡
CX482611
¡
CX482612