3.2 Special functions

Intensive level

You should select the intensive level when
browning and frying in an open pan. 

Switching on: 

(Fig. 10)

– Turn the control knob to a ventilation level (1-3).
– Press the intensive level key. The intensive level

symbol appears on the display. The previously
selected ventilation level flashes on the display.
After a few minutes, the appliance switches
back automatically to the previously selected
ventilation level.

or
– Press the intensive level key. The intensive level

symbol appears on the display. The appliance 
is now operated at the intensive level for a few
minutes and then switches off automatically.

Ending the intensive level prematurely:

– Turn the “Ventilation level” knob to the 0 position

or 

– turn the “Ventilation level” knob to any level or 
– press the intensive level key once again.

After-running

Switching on:

– Press the 

(After-running) key.

– The 

(After-running) symbol and ventilation

level 2 light up on the display (Fig. 11).

or
– Turn the “Ventilation level” control knob to any

level.

– Press the 

(After-running) key.

– The 

(After-running) symbol and the set

ventilation level light up on the display (Fig. 12).

– The extractor hood continues running for 

10 minutes. 

Switching off:

– Turn the “Ventilation level” control knob to the 0

position.

or
– Press the 

(After-running) key.

0

0

1

2

3

Fig. 10

Fig. 11

Fig. 12

0

0

1

2

3

Summary of Contents for AH600990

Page 1: ...Operating and Assembly Instructions AH 600 990 Coanda Extractor Hood 0 0 1 2 3...

Page 2: ...ing principle Page 5 6 2 1 Structure of the appliance Page 5 2 2 Accessories special accessories Page 5 2 3 Operating principle Page 6 3 Operation Page 7 8 3 1 Switching on and off Page 7 3 2 Special...

Page 3: ...the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on...

Page 4: ...th water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the correspon ding fus...

Page 5: ...ng the appliance for the first time Remove the packaging from the appliance and dispose of it properly Pay attention to the fact that there are accessories in the packaging Keep packaging elements out...

Page 6: ...key 6 Ventilation level display 7 Coanda level key 8 Light control knob 9 Ventilation level control knob 10 After running key 11 After running symbol 12 Grease filter saturation symbol 13 Coanda leve...

Page 7: ...rcoal filter special accessory must be installed The fan in the extractor hood sucks in kitchen vapours and returns them to the kitchen after purification in the grease and activated charcoal filter T...

Page 8: ...ny time To do this turn the Light control knob to the Light position Switching on the Coanda level Turn the Ventilation level control knob to the level you require Press the Coanda level key The level...

Page 9: ...the intensive level for a few minutes and then switches off automatically Ending the intensive level prematurely Turn the Ventilation level knob to the 0 position or turn the Ventilation level knob to...

Page 10: ...maximum temperature of 65 C Place the grease filters vertically in the dishwasher to ensure that no food remainders will stay on them Slight discoloration can occur when cleaning the grease filters in...

Page 11: ...he two tabs in the downward direction and remove the activated charcoal filter from the hood in the downward direction see Fig 14 Replace the old activated charcoal filter by the new one Install in th...

Page 12: ...ender all warranty claims null and void Lamp replacement Caution Disconnect the power supply before replacing lamps Caution Lamps may still be hot shortly after use Risk of burns Remove the grease fil...

Page 13: ...rved when installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm and for gas appliances 670 mm The wall hood was conceived fo...

Page 14: ...n Air recirculation You need the following accessories to install the air recirculation hood KF 600 090 activated charcoal filter Depending on the ceiling height the following duct units are at your d...

Page 15: ...holes for the hood fix the two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the includ...

Page 16: ...op of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pull the shoe down into its final position Fi...

Page 17: ...the hood fix the two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels...

Page 18: ...the 6 screws 3 5 x 9 5 mm Fig 26 Fit the top of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pul...

Page 19: ...GAGGENAU HAUSGER TE GMBH CARL WERY STR 34 81739 M NCHEN GERMANY Y 089 45 90 03 FAX 089 45 90 23 47 www gaggenau com...

Reviews: