3

1. Important notes

1.1 For your safety

Damaged appliances

must not be operated.

– The appliance must only be connected by an

authorised specialist

, paying attention to 

the relevant regulations of the power supply
companies and the regional construction
regulations. 

Also observe the assembly instructions!

Connecting cables

must not come into contact

with hot cooking surfaces.

Do not operate

the extractor hood without

inserted lamps.

– Never operate the appliance 

without a grease

filter

.

Hazardous

or explosive substances and

vapours must not be extracted!

The user

is responsible for expert use and the

perfect condition of the appliance.

– Only ever operate the appliance under super-

vision.

Caution! 

Over-greased filters are a fire risk!

Only ever deep-fry under the extractor under
constant supervision. Pay attention to cleaning
the grease filter on a regular basis. 

Fire risk!

Do not flambé meals under the

extractor hood!

– Operation of the extractor hood 

above a hearth

for solid fuels 

(coal or wood etc.) is only partly

permitted.

Gas appliances

may only be used under the

extractor hood when pots and pans are placed
on them!

– When using 

more than 3 gas-operated rings

at the same time, please operate the extractor
hood at level 2 or higher. This prevents a build-
up of heat in the appliance.

Do not place

any heavy objects on the appli-

ance; this will have a detrimental effect on
functioning.

Do not clean

the appliance with a steam

cleaning apparatus or with water pressure
because this poses a 

risk of short-circuits

.

– Isolate the appliance from the mains 

during

every maintenance operation

. To do this,

remove the mains plug or actuate the correspon-
ding fuse.
If the mains plug is not accessible, the appliance
must be deenergised by means of the domestic
installation fuse.

Repairs 

must be carried out by authorised

specialists, thus ensuring electrical safety.

No warranty claims

can be lodged 

in the

event of damage

caused by failure to observe

these instructions.

– Adequate incoming air must be ensured if a

wood, coal, gas or oil heater or an open hearth is
operated in the same room as the one in which
the hood is installed.

– Safe operation is possible whenever the partial

vacuum in the 

place where the firing equip-

ment is installed

does not exceed 4 Pa 

(0.04 mbar). This can be achieved whenever 
the air needed for combustion is able to enter
through openings that cannot be sealed, for
example in doors, windows, incoming/exhaust
air wall boxes or other technical means.

– If the appliance is to be operated 

only with the

window open

(to ensure adequate incoming

air), you can use the 

window switch

.

A switch (normally open) is fitted on the window.
On the appliance, this switch is connected to the
window switch terminal on the main electronics.
The appliance can now only be operated when
the window is open. 
Important: the window switch must only be
connected by an 

authorised specialist.

Note: The light function works without restriction.

After a power failure

, the extactor will not go

on again automatically. You can recommence
operation by turning a knob or by pressing any
key. 

Technical modifications reserved.

Summary of Contents for AH600990

Page 1: ...Operating and Assembly Instructions AH 600 990 Coanda Extractor Hood 0 0 1 2 3...

Page 2: ...ing principle Page 5 6 2 1 Structure of the appliance Page 5 2 2 Accessories special accessories Page 5 2 3 Operating principle Page 6 3 Operation Page 7 8 3 1 Switching on and off Page 7 3 2 Special...

Page 3: ...the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on...

Page 4: ...th water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the correspon ding fus...

Page 5: ...ng the appliance for the first time Remove the packaging from the appliance and dispose of it properly Pay attention to the fact that there are accessories in the packaging Keep packaging elements out...

Page 6: ...key 6 Ventilation level display 7 Coanda level key 8 Light control knob 9 Ventilation level control knob 10 After running key 11 After running symbol 12 Grease filter saturation symbol 13 Coanda leve...

Page 7: ...rcoal filter special accessory must be installed The fan in the extractor hood sucks in kitchen vapours and returns them to the kitchen after purification in the grease and activated charcoal filter T...

Page 8: ...ny time To do this turn the Light control knob to the Light position Switching on the Coanda level Turn the Ventilation level control knob to the level you require Press the Coanda level key The level...

Page 9: ...the intensive level for a few minutes and then switches off automatically Ending the intensive level prematurely Turn the Ventilation level knob to the 0 position or turn the Ventilation level knob to...

Page 10: ...maximum temperature of 65 C Place the grease filters vertically in the dishwasher to ensure that no food remainders will stay on them Slight discoloration can occur when cleaning the grease filters in...

Page 11: ...he two tabs in the downward direction and remove the activated charcoal filter from the hood in the downward direction see Fig 14 Replace the old activated charcoal filter by the new one Install in th...

Page 12: ...ender all warranty claims null and void Lamp replacement Caution Disconnect the power supply before replacing lamps Caution Lamps may still be hot shortly after use Risk of burns Remove the grease fil...

Page 13: ...rved when installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm and for gas appliances 670 mm The wall hood was conceived fo...

Page 14: ...n Air recirculation You need the following accessories to install the air recirculation hood KF 600 090 activated charcoal filter Depending on the ceiling height the following duct units are at your d...

Page 15: ...holes for the hood fix the two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the includ...

Page 16: ...op of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pull the shoe down into its final position Fi...

Page 17: ...the hood fix the two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels...

Page 18: ...the 6 screws 3 5 x 9 5 mm Fig 26 Fit the top of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pul...

Page 19: ...GAGGENAU HAUSGER TE GMBH CARL WERY STR 34 81739 M NCHEN GERMANY Y 089 45 90 03 FAX 089 45 90 23 47 www gaggenau com...