2.3 Operating principle

This extractor hood swiftly and silently extracts 
all odours produced while cooking. You can set
different intensity levels depending on the intensity
of odours. 
The exhaust air first passes through the integrated
grease filter. The grease filter intercepts and traps
the grease and odour particles in the air.

In the exhaust air mode:

The fan in the extractor hood sucks in the kitchen
vapours and passes them through the grease filter
to outdoors. The grease filter absorbs the greasy
components in the kitchen vapours (see Fig. 4).

In the air recirculation mode:

An activated charcoal filter (special accessory)
must be installed. The fan in the extractor hood
sucks in kitchen vapours and returns them to 
the kitchen after purification in the grease and
activated charcoal filter. The grease filter absorbs
the greasy components in the kitchen vapours. 
The activated charcoal filter binds odour particles
(see Fig. 5).

The “Coanda effect”

Kitchen vapours are extracted even better with the
“Coanda effect”. By means of an additional motor,
kitchen vapours are passed swiftly and effectively
into the hood’s extraction zone. An additional fan 
on the front edge of the kitchen extractor hood
generates an air stream that is diverted around a
cylinder towards the rear. This ensures that kitchen
vapours are routed completely into the extractor
hood’s filter area (see Fig. 6).

6

Fig. 4

Fig. 5

Fig. 6

Summary of Contents for AH 600-190

Page 1: ...Operating and assembly instructions AH 600 190 Extractor hood 0 0 1 2 3 ...

Page 2: ...ting principle Page 5 6 2 1 Structure of the appliance Page 5 2 2 Accessories special accessories Page 5 2 3 Operating principle Page 6 3 Operation Page 7 8 3 1 Switching on and off Page 7 3 2 Special functions Page 8 4 Cleaning and care Page 9 10 5 Maintenance Page 11 6 Assembly instructions Page12 17 6 1 Technical data Page 12 6 2 Installation Page 12 17 ...

Page 3: ... the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting value of your appliance You will find notes on Page 4 that you ought to observe before operating the appliance for the first time The chapters entitled Structure and operating principle and Operation will tell you all the things your extractor h...

Page 4: ...with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the correspon ding fuse If the mains plug is not accessible the appliance must be deenergised by means of the domestic installation fuse Repairs must be carried out by authorised specialists thus ensuring electrical safe...

Page 5: ...ing the appliance for the first time Remove the packaging from the appliance and dispose of it properly Pay attention to the fact that there are accessories in the packaging Keep packaging elements out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter entitled Cleaning and care Before operating the appliance for the first time check that the mai...

Page 6: ...r key 6 Ventilation level display 7 Coanda level key 8 Light control knob 9 Ventilation level control knob 10 After running key 11 After running symbol 12 Grease filter saturation symbol 13 Coanda level symbol 14 Intensive level symbol 15 Intensive level key Installation accessories Exhaust air Ventilation duct for ceiling heights of 2 27 2 60 m LK 600 010 Ventilation duct for ceiling heights of 2...

Page 7: ...arcoal filter special accessory must be installed The fan in the extractor hood sucks in kitchen vapours and returns them to the kitchen after purification in the grease and activated charcoal filter The grease filter absorbs the greasy components in the kitchen vapours The activated charcoal filter binds odour particles see Fig 5 The Coanda effect Kitchen vapours are extracted even better with th...

Page 8: ...any time To do this turn the Light control knob to the Light position Switching on the Coanda level Turn the Ventilation level control knob to the level you require Press the Coanda level key The level you have set and the Coanda level symbol appear on the display Fig 9 Note You can change to any ventilation level and the Coanda level remains set Switching off the Coanda level Press the Coanda lev...

Page 9: ... the intensive level for a few minutes and then switches off automatically Ending the intensive level prematurely Turn the Ventilation level knob to the 0 position or turn the Ventilation level knob to any level or press the intensive level key once again After running Switching on Press the After running key The After running symbol and ventilation level 2 light up on the display Fig 11 or Turn t...

Page 10: ... maximum temperature of 65 C Place the grease filters vertically in the dishwasher to ensure that no food remainders will stay on them Slight discoloration can occur when cleaning the grease filters in a dishwasher When replacing the grease filters wipe out the inner part of the housing with hot detergent solution Reinsert the grease filters in the hood after cleaning Install them in the reverse o...

Page 11: ...the two tabs in the downward direction and remove the activated charcoal filter from the hood in the downward direction see Fig 14 Replace the old activated charcoal filter by the new one Install in the reverse order Cleaning the extractor hood Clean the stainless steel parts of the extractor hood with mild rinsing detergent and apply stainless steel care agent to the metal surfaces using a soft c...

Page 12: ...render all warranty claims null and void Lamp replacement Caution Disconnect the power supply before replacing lamps Caution Lamps may still be hot shortly after use Risk of burns Remove the grease filters Remove the screws on the lamp cover The lamp cover tilts down and cannot be removed from the appliance Fig 15 Turn the lamp to the left and remove the lamp Fig 16 Defective lamps must only be re...

Page 13: ...bserved when installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appliances 600 mm and for gas appliances 670 mm The wall hood was conceived for the exhaust air or air recirculation mode The exhaust air can be routed into a separate exhaust air shaft or directly into the open through the outside wall It is not allowed to pass the exhaust ...

Page 14: ...r installation Air recirculation You need the following accessories to install the air recirculation hood KF 600 090 activated charcoal filter Depending on the ceiling height the following duct units are at your disposal for air recirculation LK 600 110 Ventilation duct for a ceiling height of 2 39 2 60 m LK 600 120 Ventilation duct for a ceiling height of 2 61 3 00 m The dimensions above refer to...

Page 15: ... holes for the hood fix the two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels a in the other drill holes Note Pay attention to any special accessories that you may have to fit Screw on the retaining bracket for the chimney paneling Detach the grease filters Unscrew t...

Page 16: ...top of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pull the shoe down into its final position Fig 22 Note Avoid scratches when fitting the elements into one another by placing the assembly template for example over the edge of the bottom chimney paneling to protect it Reinsert the grease filter...

Page 17: ...r the hood fix the two hooks e with the countersunk screws d Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels a in the other drill holes Note Pay attention to any special accessories that you may have to fit Detach the grease filters Unscrew the two black plates on the left and right of the chimney Hang the...

Page 18: ...ng the 6 screws 3 5 x 9 5 mm Fig 26 Fit the top of the chimney into the base Make sure that the fastening holes on the side are at the top Secure the top duct unit with 2 screws on the ceiling holder Pull the shoe down into its final position Fig 27 Note Avoid scratches when fitting the elements into one another by placing the assembly template for example over the edge of the bottom chimney panel...

Reviews: