Installation:

1.

Using the drilling template mark the position of
the screws on the ceiling.

2.

Drill 4 holes Ø 8 mm for the wall plugs. Push the
plugs flush with the ceiling (Fig. 19).

3.

Turn two screws to a 10 mm gap. Both screws
are placed in a position, in which at a later stage
of the installation the key-holes of the suppor-
ting frame are found (namely front left and back
right from the control panel of the hood). 

4.

Place the hood on a suitable base. Connect the
air outlet pipe to the hood.

5.

Screw the support frame to the hood with 
4 screws. The marking “FRONT” must be on the
same side as the control panel (Fig. 20).

Ventilation ducts LK 590-020/030/021/031
only:

the enclosed extension module should be

mounted on top of the support frame. Follow the
above instructions for mounting the support 
frame and hood.

(13 

5

/

8

") 346

(7 

7

/

8

") 200

Fig. 19

Fig. 20

Note:

the extractor hood is to be installed to a kitchen
ceiling or suspended ceiling. Ensure that the 
ceiling is capable of providing a firm hold for a
maximum weight of hood and accessories of 60 kg.

Before marking the securing holes, make sure that
no electricity wires or water pipes or other wires/
pipes are laid at the drilling points in the ceiling.

Before installation check the enclosed wall plugs
and screws are suitable for your ceiling. If neces-
sary use special wall plugs.

Summary of Contents for AH 590-720

Page 1: ...Operating and assembly instructions AH 590 720 Freely Suspended Insular Hood...

Page 2: ...1 AH 590 720 6 Assembly instructions Page 13 19 6 1 Technical data Page 13 6 2 Installation Page 14 19...

Page 3: ...or perfect functioning of the appliance at its installation location He must explain the operating principle of the appliance to the user with refe rence to the operating instructions He must explain...

Page 4: ...ons must be observed when installing the hood The minimum distance from the worktop to the bottom edge of the wall hood is for electrical appli ances 24 600 mm and for gas appliances 30 762 mm The ext...

Page 5: ...t air shaft our condensate separator RV 060 150 must be installed in the exhaust air line The condensate separator must still be accessible after installation The duct units listed below are available...

Page 6: ...hob During operation the heat load of all hotplates and oven must not exceed 13 5 kW Should the nominal heat loads of all hotplates com bined exceed 13 5 kW e g combination with WOK burner during ope...

Page 7: ...ust be on the same side as the control panel Fig 20 Ventilation ducts LK 590 020 030 021 031 only the enclosed extension module should be mounted on top of the support frame Follow the above instructi...

Page 8: ...Stainless steel ventilation ducts only LK 590 010 020 030 pull the protective film off the metal surface 8 Place both ventilation ducts over the support frame Take care not to scratch the sensitive d...

Page 9: ...on the support frame Fig 24 Note avoid scratches when pulling the ele ments apart by placing the assembly template for example over the top edge of the bottom duct to protect it 15 Replace the glass p...

Page 10: ...1 McFADDEN AVENUE HUNTINGTON BEACH CA 92649 USA Y 800 828 9165 FAX 714 901 0979 www gaggenau com us GAGGENAU HAUSGER TE GMBH P O BOX 10 02 50 D 80076 M NCHEN GERMANY Y 0 89 45 90 01 FAX 0 89 45 90 23...

Reviews: