14
‒
Depending on the installation situation, the
exhaust air can be guided in three different
directions.
‒
Corresponding to the space conditions, the
connection piece can be turned by 180°.
‒
For details of exhaust air guidance, also refer
to the instructions for the remote fan unit.
5
Secure the exhaust air pipe to the connecting
pieces and seal appropriately..
Notes
‒
The extracted air from gas-fired appliances
must not be guided through flat ducts. Due to
the higher extracted air temperature, these
may become deformed.
‒
When combined with gas-fired appliances, use
aluminium pipes.
‒
If you use an aluminium pipe, smooth the
connection area beforehand..