GAC EEG6500 Manual Download Page 4

4

© 2018 Copyright All Rights Reserved

EEG6500 Enhanced Electronic Governor

   

05.09.18

    

 

PIB 5010

 

F

10

ADVANCED PARAMETERS MENU

ADVANCED MENU PARAMETERS (CONFIGURABLE)

Parameter

Definition

Range

Default

AUX

Auxiliary Input 

Enable

145 Hz/volt, 5 volt nominal Range: 1-9 V 

Off, On  

Off

VSPD

Variable Speed

 or Trim Select

(On=Variable Speed, Off=Trim)

Off, On  

 Off

LFG

Light Force Governor

Off, On  

Off

LEAD

Lead Circuit 

-  For Increased Governor 

Response / Increased GAIN Adjustment 

Authority.

Off, On  

On

NLCU

No Load Current 

- Amps

0.0 - 9.5

0.5

FLCU

Full Load Current 

- Amps

0.5 - 10.0

4.0

ADVANCED MENU PARAMETERS (READ ONLY)

Parameter

Definition

SREV

Software revision number

BID

Software build identifier

AREV

Assembly revision: Identifies board hardware configuration, not 

software.

FLTH

Highest fault code since power up. Aids in trouble shooting.

DATL

Supplemental data associated with last fault code. Aides in trou-

bleshooting.

FLTL

Last fault code detected. Associated data is DATL and aids in 

trouble shooting.

Previous

Parameter

Next

Parameter

Selecting Parameters:

Display Special
Menu Parameters:

Hold ALL 3          until

“AUX” appears in display

Return to Quikset Menu:

Hold ALL 3         for 2 seconds

Adjust Parameters:

Increase

Parameter
Decrease

Parameter

1. After 3 minutes of no user input, EEG switches to Quikset Menu.
2. “Lock” is displayed when attempt to change a Read-Only

                       parameter.

NOTE

9

ADJUSTING FOR DROOP

EXAMPLE

8

ADJUSTING FOR STABILITY

GAIN - RATED SPEED & IDLE SPEED

 Once the engine is running at operating speed and at no load, the following 

governor performance adjustments can be made to increase engine stability.

GAIN TYPE

ADJUSTMENT PROCEDURE

RATED SPEED

1.

Selected when IDLE input is disconnected.

The EEG6500 is equipped with two separate gains, one for rated 
speed, the other for idle speed.  Both are set using the GAIN set-

ting on the Quikset menu.  

NOTE

NOTE

IDLE SPEED

1.
2.
3.

Connect the idle input to ground.
Change GAIN value.
Disconnect Idle input from ground to switch back to Rated.

Idle icon will blink.

QUIKSET MENU

PARAMETER

ADJUSTMENT PROCEDURE

A.

GAIN

1.
2.
3.

4.

Increase this parameter until instability develops. 
Then, gradually decrease this parameter until stability returns.
Finally, decrease this parameter one increment further to ensure 

stable performance. 
If instability persists, adjust the next parameter.

B.

STABILITY

1.

2.

Follow the same adjustment procedure as the GAIN parameter.
If instability persists, adjust the next parameter.

C. DEADTIME 1.

If fast instability occurs, switch DEADTIME to low and repeat 

steps A & B.

Normally, adjustments made at no load achieve satisfactory per-
formance. For further performance, refer to sections (10) & (11).

NOTE

EEG6500 - Variable Speed Response to External Voltage Input  

Variable Speed Parameter (VSPD)- ‘ON’

After the initial set up is completed and the # of Teeth, Crank Termination 

Speed and Rated Speed are set, position the external switch connecting 

terminals ‘H’ and ‘K’ on to activate the DROOP mode following these sequence 

steps.

1.  Go to the Advanced menu: Press and hold all three buttons simultaneous-

ly for two seconds to switch to Advanced Menu. 

2.  Confirm that the 

VSPD

 (Variable Speed / Fixed Speed Control) is off. 

Default position is off.  

3.  Confirm that the 

LEAD

 circuit is off. Default position is ON. 

4.  Set the 

NLCU

 (No Load Current) to the measured / displayed current 

value when operating at no load rated speed (default value is 0.5 amps.) 

5.     Set the 

FLCU

 (Full Load Current) to the measured / displayed current     

         value when operating at full load rated speed (default value is 4.0 amps.) 

6.     Return to the Main Menu: Press and hold all three buttons simultaneously  

        for two seconds to switch to the Main Menu. 

7.     Select and set DROOP to the desired percentage. 

8.     Change the Speed parameter, which turns into the ‘DROOP OFFSET’.          

         This sets the RPM, above operating speed, to which the system will be    

        commanded when DROOP is enabled. This is an offset value.  

 

1500 RPM operating speed x 0.05 (5.0% droop) = 75 RPM 

Input 75 RPM, this is the offset value.

The 

NLCU

 entered must be less than the 

FLCU

 and the differnece between 

the two must be at least 0.5A.  If an invalid combination is entered a warning 

will be flagged and the parameters will be default to 0.5A and 4.0A.

Summary of Contents for EEG6500

Page 1: ...t Display mm in Dimensions COM VSPD EEGEnhanced Electronic Governor 6500 www governors america com CAUTION ENGINE SPEED CONTROL COMPONENT SEE PRODUCT PUBLICATION WHEN INSTALLING OR SERVICING N P CAN M...

Page 2: ...3 Parameter Adjust Up Parameter Adjust Down Increment a Parameter Value HOLD and TAP or Rapidly Increment a Value HOLD and HOLD or Locking Unlocking the Display Press and hold both the UP and DOWN ar...

Page 3: ...or position at the start of cranking Droop to apply under maximum load based on current of actuator Actuator position increase in percent per second from cranking to low idle speed starting from the S...

Page 4: ...l blink QUIKSET MENU PARAMETER ADJUSTMENT PROCEDURE A GAIN 1 2 3 4 Increase this parameter until instability develops Then gradually decrease this parameter until stability returns Finally decrease th...

Page 5: ...EAD CIRCUIT Turning the Lead Circuit LEAD ON default is ON enables the governor to be more responsive and typically increases the range of GAIN adjustement Turn Lead Circuit ON when there is slow or m...

Page 6: ...k and failures will cause a system shut down 11 FAULT CODES ADVANCED MENU PARAMETERS CONFIGURABLE CODE CAUSE EFFECT CUSTOMER ACTION 1 Actuator over current continuous Actuator turned off for 30 sec Ch...

Page 7: ...america com www governors america com SYMPTOM NORMAL READING PROBABLE CAUSE OF ABNORMAL READING Engine Over Speeds 1 Do Not Crank Apply DC power to the governor system 1 If the actuator is at minimum...

Page 8: ...R SETTINGS Parameter Factory Settings Customer Settings Gain 50 Rated 10 Idle Stability 50 Deadtime HI Speed 1500RPM Idle 900 RPM Fuel Limit 100 Start Fuel 100 Droop 5 0 Fuel Ramp 10 Speed Ramp 300 RP...