background image

Air Conditioner

Owner's Manual

                      

 

MODELO:

 

        

                              

IGB09MB-K3DNB7G

                              

IGB12MB-K3DNB7G

IGB18MC-K3DNB7G

                                

  

Split Air Conditioner

Thank you for choosing our product.

If you have lost the Owner’s Manual, please contact the local agent or visit 

www.elnur.es or sent email to [email protected] for electronic version.

For proper operation, please read and keep this manual carefully. 

Summary of Contents for IGB09MB-K3DNB7G

Page 1: ...8MC K3DNB7G Split Air Conditioner Thank you for choosing our product If you have lost the Owner s Manual please contact the local agent or visit www elnur es or sent email to elnur elnur es for electronic version For proper operation please read and keep this manual carefully ...

Page 2: ......

Page 3: ...Test and operation Test operation 33 Attachment 34 Pipe expanding method 36 This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from un controlled waste disposal recycle it responsibly to promote the sustainable reuse of mate rial resources To return your used device please use the...

Page 4: ...ppliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not wash the air conditioner with water to avoid electric ...

Page 5: ...damage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not spill water on the remote controller otherwise the electric shock or damage Please contact dealer when you need to repair air conditioner Do not repair air conditioner by yourself It may cause object...

Page 6: ...bles before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Properly connect the live wire neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity please...

Page 7: ...onnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance should comply with national electric safety regulations The air conditioner is the first class electric appliance It keep the interconnection cable away from the copper tube The temperature of refrige...

Page 8: ...be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be Working temperature range NOTICE Indoor side DB WB C Outdoor side DB WB C Maximum cooling 32 23 43 26 Maximum heating 27 24 18 The operating temperature range outdoor temperature for cooling is 15 43 Heating tem...

Page 9: ... air outlet Connection wire Parts name Indoor Unit air inlet panel aux button horizontal louver air outlet heating indicator temp indicator cooling indicator power indicator receiver window drying indicator display remote control NOTICE Actual product may be different from above graphics please refer to actual products 6 ...

Page 10: ...IGHT button 7 CLOCK button 6 TIMER ON button Up down swing Child Lock set time TIMER ON TIMER OFF turbo mode set temperature X fan send signal set fan speed light Temp display type Set temp Outdoor ambient temp Indoor ambient temp Sleep mode Heat mode Fan mode Dry mode Cool mode Auto mode Operation mode air mode ON OFF MODE FAN X FAN TURBO TEMP TIMEROFF SLEEP LIGHT 2 5 6 10 13 12 11 9 8 3 4 7 1 TI...

Page 11: ...t indicator on indoor unit is ON You can press or button to adjust set temperature Press FAN button to adjust fan speed Press button to adjust swing angle Cooling only unit can t receive the signal for heating mode Introduction for buttons on remote controller Note After putting through power air conditioner will give out a sound and operation indicator is ON red indicator You can operate the air ...

Page 12: ...an motor will adjust the fan speed high medium or low speed according to ambient temperature Fan speed under dry mode is low speed Press this button can select up down swing Swing angle can be selected in sequ ence as below When selecting with remote controller it s auto swing Horizontal louver of air conditioner will swing up down automatically at the maximum angle When selecting swing Horizontal...

Page 13: ... increase or decrease half an hour When holding or button 2s later the time will change quickly until to Cancel TIMER OFF Press TIMER button again under TIMER OFF status At OFF status press this button once can set TIMER ON Please refer to TIMER off for detailed operation Cancel TIMER ON Press TIMER button again under TIMER ON status Press this button the clock can be set up signal blink and displ...

Page 14: ...press X FAN button can turn off X FAN function Indoor fan stops operation immediately Press this button can see indoor set temperature indoor ambient temperature or outdoor ambient temperature on indoor unit s display Temperature is set circularly by remote controller as below no display When selecting by remote controller or no display temperature indicator on indoor unit displays set temperature...

Page 15: ...will be displayed on remote controller Press this button again to cancel sleep function icon on remote controller will be displayed Press this button can turn off the light for indoor unit s display icon on remote controller will disappear Press this button again to turn on the light for indoor unit s display icon on remote controller will be displayed Child lock function Switchover function for t...

Page 16: ...o obstacles between them or wireless telephone remote controller should be close to indoor unit during operation Replace new batteries of the same model when replacement is required When you don t use remote controller for a long time please take out the batteries If the display on remote controller is fuzzy or there s no display please replace batteries 1 After putting through the power press but...

Page 17: ... the air conditioner The operation in details are as below WARNING NOTICE Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric shock Do not use volatile liquid to clean the air conditioner Clean surface of indoor unit When the surface of indoor unit is dirty it is recommended t...

Page 18: ...n panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly operation environment clean frequency can be increased WARNING 15 ...

Page 19: ...ge pipe is damaged 1 Disconnect power supply 3 Check whether mounting bracket for outdoor unit is damaged or corroded If yes please contact dealer Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air conditioner please contact local dealer or consultant service center for the correct disposal method...

Page 20: ...m Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Check the batteries If the power of batteries is too low please replace them Take the remote controller close to indoor unit Turn off the fluoresent lamp and then try it again...

Page 21: ...or temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temper ature can t be adjusted Unit is operating under auto mode Temperature can t be adju sted under auto mode Please switch the operation mode if you need to adjust temperature Your required temperatur...

Page 22: ...again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing inside the unit which is a normal phenomenon Cracking noise Air conditioner is turned on or turned off just now This is the sound of frict...

Page 23: ...sting or oil return mode It is normal The indicating lamp in heat mode will wink 0 5s and light 10s E5 overcurrent protection Power indicator blinks and E5 is displayed C5 Connector jumper malfunction Check if the connector jumper contacts the properly If replace the PCB please take off the old for the new PCB F1 Indoor ambient temp sensor malfunction Check if indoor room temp sensor is connected ...

Page 24: ...st 50cm At least 30cm At least 300cm At least 200cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the ceiling Space to the obstruction Space to the obstruction At least 30cm At least 15cm At least 15cm Space to the wall Space to the wall Space to the wall 21 ...

Page 25: ...ied power cord Basic requirement Outdoor unit Indoor unit Installing the unit in the following pla ces maycause malfunction If it is un avoidable please consult the local dealer 1 The place with strong heat sources vapors flammable or explosive gas or volatile objects spread in the air 2 The place with high frequency devices such as welding machine medical equipment 3 The place near coast area 4 T...

Page 26: ...lled in accordance with national wiring regulations 10 Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yellow green wire in air conditioner is grounding wire which can t be used for...

Page 27: ...d be a little lower than the wall mounted frame shown as below Step three open piping hole 2 Open a piping hole with the diameter of Φ55 on the selected outlet pipe position In order to drain smoothly slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 5 10 18K 09 12K Left Wall Φ55mm Φ55mm Right Mark in the middle of it Level meter Rear piping hole Wall Spa...

Page 28: ...g out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear left left rear left right rear right Step four outlet pipe Installation of indoor unit Note Pay attention to dust prevention and take relevant safety measures when opening the hole The plastic expansion pa...

Page 29: ... 45 55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pipe Note Add insulating pipe in the indoor drain hose in order to prevent condensation The plastic expansion particles are not provided 1 Open the panel remove the screw on the wiring cover and then ...

Page 30: ...nit and outdoor unit should be connected by a professional for a new one Avoid extending the wire by yourself installation For the air conditioner without plug an air switch must be installed in the line The air switch should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the ...

Page 31: ...rately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the indoor unit 1 Put the bound pipes in the wall pipe and then make them pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing...

Page 32: ...r the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10000W 16000W 10 expansion screws are needed Step two install drain joint g n i t a e h d n a g n i l o o c r o f y l n O unit 1 Connect the outdoor drain joint into the hole on the chassis as shown in th...

Page 33: ...liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m Φ 6 Φ 9 52 Φ 12 Φ 16 Φ 19 30 40 45 55 60 65 70 75 15 20 1 Remove the wire clip connect the power connection wire and signal control wire only for Heat pump type to the wiring terminal according to the color Indoor unit connection Indoor unit connection N 1 2 3 blue brown black yellow green 12 18K Cool only type and ...

Page 34: ...lightly dow nwards The drain hose can t be curved raised and fluctuant etc The water outlet can t be placed in water in order to drain smoothly Installation of outdoor unit U shaped curve wall drain hose the drain hose can t raise upwards The drain hose can t be fluctuant The drain hose can t be fluctuant The water outlet can t be fluctuant The water outlet can t be placed in water Note 2 Fix the ...

Page 35: ...e decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant charging vent 7 Reinstall the handle Use vacuum pump liquid valve gas valve refrigerant charging vent nut of refrigerant charging vent vacuum pump piezometer valve cap Lo Hi inner hexagon spanner open clo...

Page 36: ...it grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause insufficient cooling heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection...

Page 37: ...refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Cooling capacity Cooling capacity 5000Btu h 1465W 24000Btu h 7032W 7000Btu h 2051W 28000Btu h 8204W 9000Btu h 2637W 36000Btu h 10548W 12000Btu h 3516W 42000Btu h 12...

Page 38: ...r of connection pipe Liquid pipe mm Gas pipe mm Φ6 Φ6 or Φ9 52 Φ12 Φ16 Φ19 Φ22 2 Φ9 52 or Φ12 Φ16 or Φ19 Φ19 or Φ22 2 Φ25 4 or Φ31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 50 20 Outdoor unit throttle Configuration of connection pipe 35 ...

Page 39: ...itable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander Note A is different according to the diameter please refer to the sheet below expander hard mold pipe F Inspection Check the quality of expanding port If there is any blemish expand the p...

Page 40: ...28110 Algete Madrid Tfno de Atención al Cliente 34 91 628 1440 www elnur es www elnur global com www elnur co uk As a part of the policy of continuous product improvement Elnur s a reserves the right to alter specifications without notice ...

Reviews: