10.2013 | G28062 | Printed in Germany
Resetting the drives:
Resetting a Solo drive
•
Isolate the drive from the power supply.
•
Undo the chain of the drive from the window.
•
Set the DIP switch of the drive as follows:
DIP-switch
1
2
3
4
Drive with VAN
OFF OFF ON
ON
Drive without VAN OFF OFF ON
OFF
2
3
4
1
ON
Drive with VAN
2
3
4
1
ON
Drive without VAN
•
Connect the drive to the power supply again. The drive starts with the learning process. The
chain moves in and out and then stops in the end position (chain run out by approx. 6 cm).
•
Isolate the drive from the power supply
•
Set the travel via DIP switch 1 and 2 (see Page 29)
•
Connect the drive to the power supply again
Resetting Synchro drives
•
Ensure that the synchronisation cables of all drives are connected correctly (see connec-
tion diagrams from Page 35).
•
Isolate the drives from the power supply.
•
Undo the chain of the drives from the window.
•
Set the DIP switch of the drives as follows:
DIP-switch
1
2
3
4
Drive with VAN
OFF OFF ON
ON
Drive without VAN OFF OFF ON
OFF
•
Connect the drives to the mains again. The drives start with the learning process. The chains
move in and out and then stop in the end position (each chain run out by approx. 6 cm).
•
Ensure that the chains of all drives have run out equally (approx. 6 cm).
If the chains have not run out equally, start the reset process from the beginning again.
•
Isolate the drives from the power supply
•
Set the DIP switch of the drives as follows:
DIP-switch
1
2
3
4
Drive with VAN
OFF OFF OFF ON
Drive without VAN OFF OFF OFF OFF
•
Connect the drives to the mains again. The drives now learn their new address.
The blue LED (in the opening of the DIP switches) of each drive starts to flash correspond
-
ing to their position in the system.
Ensure that the LEDs of the drives connected flash differently.
(The first drive flashes 1 x short flash - pause - 1 x short flash - pause...“,
second drive flashes 2 x short flash - pause - 2 x short flash - pause...“).
Repeat this procedure in case of an error!
•
Isolate the drives from the power supply
•
Set the desired travel via DIP switch 1 and 2 (see Page 29)
•
Connect the drives to the mains again.
2
3
4
1
ON
Drive with VAN
2
3
4
1
ON
Drive without VAN
2
3
4
1
ON
Drive with VAN
2
3
4
1
ON
Drive without VAN