G-Tek LM Pro RF Operating Manual Download Page 6

 

G-Tek Corporation Pvt. LTD  

 

Introduction 

 

1.3

 

 

F

EATURES

 

Following features

*

 are available for this LM Pro RF. 

 

RF based data logger 

 

Up to 100 m range (Line of Sight)  

 

No wiring required  

 

Quick to deploy 

 

Quick connect / disconnect port for pressure input 

 

Large individual display 

 

Long battery life > 1year at 15min Store interval 

 

Resolution of 0.1 

 

Up to 32000 data storage 

 

Optional USB power source.  

 

Features depends on the product ordered. Please refer to the order code (Model No) of your product for exact features 

and capabilities.  

1.4

 

 

U

NPACKING AND INSPECTION OF 

LM

 

P

RO 

RF

 

 

LM  Pro  RF  is  dispatched  in  a  recyclable,  environment  friendly  package  specially  designed  to  give 
adequate  protection  during  transit.  If  the  outer  box  shows  sign  of  damage,  it  should  be  opened 
immediately, and the LM Pro RF be examined. If there is evidence of damage, the instrument should 
not be operated, and the local representative contacted for instructions. Ensure that all accessories 
and documentation is removed from the box. If the LM Pro RF is for immediate use, you can start 
installing it as per following instructions. 

Please preserve the original packing along with all internal 

packing for future transport requirements. 

The figure 1 shows the front view of LM Pro RF device. 

 

Figure 1 Front View of LM Pro RF  

Summary of Contents for LM Pro RF

Page 1: ...LM RF Temp RH Datalogger Model No 6xx G Tek Corporation Pvt Ltd 3 mahavir estate karelibaug vadodara 390 018 tel 91 265 2461912 email info gtek india com url www gtek india com OPERATING MANUAL LM H...

Page 2: ...s 5 1 4 Unpacking and inspection of LM Pro RF 5 1 4 1 Status LEDs 6 1 4 2 Display LCD 6 Installation 7 Operation 8 3 1 LM Pro RF Internal Schematics Diagram 8 3 2 LM Pro RF OPERATION 8 Troubleshooting...

Page 3: ...List of Figures Figure 1 Front View of LM Pro RF 5 Figure 2 LCD Display 6 Figure 3 Schematic diagram of Set up of LM Pro RF 7 Figure 4 Internal Schematic diagram of LM Pro RF 8 Figure 5 5 VDC 1 2 Amp...

Page 4: ...G Tek Corporation Pvt LTD 3 List of Tables LIST OF TABLES Table 1 Manual Layout 4 Table 2 Specification of LM Pro RF 11 Table 3 Sensor types and range 12 Table 4 LM Pro RF Order Code 13...

Page 5: ...nd comparing it with the code on the LM Pro RF user can find out the installed options 1 2 LM PRO RF DESCRIPTION The LM Pro RF series of wireless data logger is a new RF based data logger measuring te...

Page 6: ...INSPECTION OF LM PRO RF LM Pro RF is dispatched in a recyclable environment friendly package specially designed to give adequate protection during transit If the outer box shows sign of damage it shou...

Page 7: ...ll be flickered with Heartbeat LED if Batch is ON at every 5 minutes Otherwise Storage LED will remain in OFF state if Batch is OFF 1 4 2 Display LCD The LCD display is 3 digit display shows the Tempe...

Page 8: ...sing ethernet cable for communication Please refer the schematic diagram given in figure 3 for setting up the connection The PC must have GtekNet application to configure the Moderator for observing t...

Page 9: ...pdated The STR led will flicker with HBT Led at 5 minutes time interval if Batch is running Otherwise STR led will remain in OFF state When the Batch is running recording indication is shown on LCD di...

Page 10: ...LED will be flickered and Temp and RH will be updated If HRT LED does not flicker then contact to Gtek Corporation How is Alarm condition shown on LCD display When Alarm occurs it will be shown on LCD...

Page 11: ...ard Accessories STANDARD ACCESSORIES 5 1 5 V DC 1 2 AMP ADAPTOR Figure 5 5 VDC 1 2 Amp Adaptor Input Voltage 100 240 V AC 0 35 Amp Operating Frequency 50 to 60Hz Output voltage 5V DC 1 2 Amp 5 2 ETHER...

Page 12: ...ords totals Rollover Environmental Temperature Operation 5 C to 45 C Limiting 0 C to 50 C Storage 20 C to 60 C Humidity Operation 10 to 80 RH Non Condensing Storage 5 to 90 RH Non Condensing Altitude...

Page 13: ...t LTD 12 Specification Table 3 Sensor types and range Parameter Sensor Range Accuracy Temperature Thermistor 20 to 60 C 0 5 C Temperature RH Solid state Temp 20 to 60 C 0 5 C RH 0 100 2 RH between 20...

Page 14: ...er Code Series Input Type Power Supply Mounting Type Software Communication Interface 6 LM Pro RF 1 Temp 0 Battery Operated 0 Handheld 4 GtekNet Non Secure 6 Radio Frequency RF 2 Temp RH 1 Battery Mai...