background image

32 

 

13

 

    Specification

 

MODEL 

GL-6060L 

GL-6150L 

GL-6300L 

GL-6500L 

Dual Interval 

Dual Interval 

Dual Interval 

Dual Interval 

Capacity 

30/60 lbs 

60/150 lbs 

150/300 lbs 

250/500 lbs 

Graduation 

0.01/0.02 lbs 

0.02/0.05 lbs 

0.05/0.1 lbs 

0.1/0.2 lbs 

External Resolution 

1/3000 

1/3000 

1/3000 

1/2500 

Internal Resolution 

1/60000 

1/75000 

1/60000 

1/50000 

MAX Tare 

-29.99 lbs 

-59.98 lbs 

-149.95 lbs 

-249.9 lbs 

Capacity 

15/30 kg 

30/60 kg 

60/150 kg 

100/200 kg 

Graduation 

5/10 g 

10/20 g 

20/50 g 

50/100 g 

External Resolution 

1/3000 

1/3000 

1/3000 

1/2000 

Internal Resolution 

1/60000 

1/60000 

1/75000 

1/40000 

MAX Tare 

-14.995 kg 

-29.99 kg 

-59.98 kg 

-99.95 kg 

Display 

LCD 6Digit 

LCD 

5.1 x 1.8 inch    /    130 x 48 (mm) / Large LCD 

LCD Symbol 

ZERO, NET,  ○  (stabilization lamp) lb, kg, BATTERY (3 stages)

 

Keys 

ZERO, TARE, PRINT, UNIT, ON/OFF:    5 functions in total 

Sensor 

Load Cell 

Power 

AC Adaptor: (SMPS)   

Input: 100 V~240 V / 50~60 Hz,    Output: DC 6 V / 0.5 A   

Operation Time 

Alkaline: about 300 hours,    Manganese: about 50 hours 

Operating 

Temperature 

14 

  ~ 104 

℉ 

-10  ℃  ~ +40  ℃   

Interface 

RS-232C 

Platform Size 

13.9(W)  ×  16.8(D) inch   

355(W)  ×  427(D) mm 

Product Size 

13.9(W)  ×  23.1D)  ×  3.4(H) inch 

355(W)  ×  589(D)  ×  88(H) mm   

Product Weight 

About : 15.3 lb / 6.95 kg 

Feature 

Setting Upper/Lower Limit and Buzzer Sound. 

Option 

Battery    C-Type (LR14) 1.5V/4EA 

 

※ 

The specifications of the product are subject to change without notice for the quality improvement.

 

 

 

Summary of Contents for GL-6000L Series

Page 1: ...PORTABLE ELECTRONIC SCALE Service Manual GL 6000L Please read this manual before using Keep this manual in safe location after reading Series ...

Page 2: ...2 ...

Page 3: ...g Mode 13 5 1 How to Enter Gravity Acceleration Setting Mode 13 6 General Setting Mode 13 6 1 How to Enter General Setting Mode 13 7 User Setting Mode 16 7 1 How to Enter User Setting Mode 16 7 2 Description of User Settings 16 8 Communication Interface RS 232C 20 8 1 RS 232C Pin Arrangement and Connection 20 8 2 Signal Format 20 8 3 Data Format 20 9 How to Download Program 22 9 1 Downloader Conne...

Page 4: ...nal injury or property damage In this manual possible hazardous situations are informed in order to prevent any accident Such situations are displayed in different categories Warning Caution and Notice 1 Unauthorized duplication of this manual in part or in whole is prohibited 2 The contents of this manual are subject to change without notice 3 If there is any incorrect or missing information in t...

Page 5: ...5 ...

Page 6: ...6 ...

Page 7: ...ght on the platform Platform Placing an object to be weighted Level Checking if the product is level Handle Convenient when moving the product Limit Bolt Load Cell Limit Bolt Battery C SIZE 1 5V 4 EA Adjust Foot Used to level the product Communication Port RS 232C type RJ11 Connector Adapter Jack ...

Page 8: ...8 2 2 Product Size ...

Page 9: ...ht is stable ZERO Zero display lamp It is turned on when the weight is 0 NET Tare display lamp It is turned on while net weight is displayed when tare function works Ib kg Measurement unit display lamp It displays measurement unit Remaining battery display lamp It displays remaining battery 3 stages ...

Page 10: ... you can adjust the upper Limit lower limit of value 1 When the PRINT Key is pressed after placing an object on the platform the current weight is transmitted via communication port 2 When the PRINT Key is pressed without an object on the platform the total amount of weight is printed out when printer output is used 1 When pressed short measurement unit changes 2 When pressed long the upper limit ...

Page 11: ...NT Key while CAL is shown on the display to display the current maximum weight Use below Keys to change the maximum weight UNIT Key Use to change the maximum weight PRINT Key Use to save a newly set maximum weight and return to the previous page Test Type Description A D Test Don t press any Key to show the current A D value on the display Communication Test Press TARE Key to show Serial test ok o...

Page 12: ...start weight adjustment UNIT Key Use to change the standard weight TARE Key Start weight adjustment END Once the weight adjustment is completed END is shown on the display and Measurement Mode is started 4 2 3 How to Proceed with Multi Calibration It allows to adjust weight through 3 sections Press UNIT Key while CAL is shown on the display to display C ZERO and proceed with multi calibration Stag...

Page 13: ...brate it 6 General Setting Mode 6 1 How to Enter General Setting Mode Press ON OFF Key to turn on the power and press ZERO and TARE Keys until the booting is completed to show p zero on the display and enter General Setting Mode Use below Keys to change settings UNIT Key Change setting type and setting value TARE Key Select settings Description of General Setting Mode Type Initial Value Setting Va...

Page 14: ...g value is set 50 zero function will happen if the remaining value is within graduation 0 5 5d 10d 15d 20d 25d 30d 35d 40d 45d Type Initial Value Setting Value Description u kg kg on It sets a decimal points e g When comma is selected decimal points will be displayed as kg off Type Initial Value Setting Value Description u lb lb on It sets a decimal points e g When comma is selected decimal points...

Page 15: ...ng Value Description dot comma It sets a decimal points e g When comma is selected decimal points will be displayed as semi colon Type Initial Value Setting Value Description save It saves new settings and enters Measurement Mode ...

Page 16: ... Off Time Settings Type Initial Value Setting Value Description disable It sets auto off time If the scale is stable for the preset time it is turned off automatically Notice If the auto off time is set 10min the product is automatically turned off after 10 minutes 3min 5min 10min 20min 30min 40min 50min 60min Backlight Brightness Setting Type Initial Value Setting Value Description darkest It adj...

Page 17: ...sable Not used It sets Communication Printer Output Mode stre s Serial Stream comm s Serial Command stab s Serial when the weight is stable keyz s Serial when the ZERO Key is pressed stab p Printer when the weight is stable keyz p Printer when the ZERO Key is pressed Baud Rate Setting Type Initial Value Setting Value Description br 24 It sets baud rate Notice It communicates in 9600bps when settin...

Page 18: ...ue Setting Value Description disable It disables buzzer sound It sets buzzer motion enable It enables buzzer sound Type Initial Value Setting Value Description Form 1 It sets printer format Refer to the following format Form 2 Form 3 Form 3 It sets RS 232C Communication Data Format Refer to 5 3 Data Format Form 3 Data Format 1 Form 4 Data Format 2 Form 4 Form 1 Form 2 ...

Page 19: ... weight upperlimit o side Currentweight lower limitorcurrentweight upperlimit lo Currentweight lower limit hi Currentweight upper limit Buzzer Sound of Limit Function Setting Type Initial Value Setting Value Description off It turns off buzzer sound It sets the buzzer sound interval while limit function is on 1 t 1 time per second 2 t 2 times per second Limit Function Setting Type Initial Value Se...

Page 20: ...ormat 8 3 1 Data Format 1 18 Byte 8 3 1 1 Header 1 2 Byte US Unstable Display ST Stable Display OL OVER LOAD 8 3 1 2 Header 2 2 Byte GS Gross Weight NT Net Weight 8 3 1 3 DATA 8 Byte 2B H PLUS 2D H MINUS 20 H SPACE 2E H DECIMAL POINT 8 3 1 4 Unit kg lb LSB MSB 1 1 0 1 0 0 1 0 Low High START BIT STOP BIT NEXT START BIT CR LF Header 1 Header2 Data Parity bit Unit RJ 11 Port ...

Page 21: ...ght NT Net Weight 8 3 2 3 Equipment No 0x0 8 3 2 4 Lamp Status 8 3 2 5 DATA 8 Byte When the weight date including a decimal for example 13 5 kg 8 bytes of ASCII code corresponding to 0 0 0 0 1 3 and 5 are sent 8 3 2 6 Blank 1 Byte 8 3 2 7 Unit kg lb Bit7 1 Bit6 Stable Bit5 0 Bit4 Hold Bit3 Printer Bit2 Gross Weight Bit 1Tare Bit 0 Zero Point ...

Page 22: ...22 9 How to Download Program 9 1 Downloader Connection ...

Page 23: ...23 9 2 How to Download STEP1 Initiate HOPE3000FOR8051 program STEP2 Click File Open and Download ...

Page 24: ...24 STEP3 Choose hex file STEP4 Select HT85F2280 and click 0K ...

Page 25: ...25 STEP5 Choose ICP e C0N12C and click OK STEP6 Click Smart Programming ...

Page 26: ...26 STEP7 Move Erase Blank Check Program and Verify on the left to the right and click Set Writer STEP8 Click Auto to start the program download ...

Page 27: ...e program download u powe is displayed first and then lb Use below Keys to set default unit Key Change unit kg or lb Key Save the unit setting Set only once after the program download In order to change default unit afterwards please refer to Chapter 6 General Setting Mode ...

Page 28: ...he maximum weight Empty the platform before turning on the power There is a problem in load cell Refer to the service center ZERO or TARE Keys are pressed only when the scale is stable Check stabilization status when pressing Keys The value of lower limit exceeds the value of upper limit Make sure upper limit is higher than lower limit The upper lower limit value does not meet the minimum graduati...

Page 29: ...29 11 How to Sealing ...

Page 30: ...30 12 GL6000L Series MS EXPLODED ...

Page 31: ...31 ...

Page 32: ...5000 1 40000 MAX Tare 14 995 kg 29 99 kg 59 98 kg 99 95 kg Display LCD 6Digit LCD 5 1 x 1 8 inch 130 x 48 mm Large LCD LCD Symbol ZERO NET stabilization lamp lb kg BATTERY 3 stages Keys ZERO TARE PRINT UNIT ON OFF 5 functions in total Sensor Load Cell Power AC Adaptor SMPS Input 100 V 240 V 50 60 Hz Output DC 6 V 0 5 A Operation Time Alkaline about 300 hours Manganese about 50 hours Operating Temp...

Page 33: ...33 MEMO ...

Page 34: ...34 MEMO ...

Page 35: ...35 MEMO ...

Page 36: ...trial Complex 29 Sandan ro 68beon gil Uijeongbu si Gyeonggi do Korea 11781 100Temple Ave Hackensack NJ 07601 Tel 1 201 679 7793 USA Branch Head Office Distributed by www visiontechshop com www gtech21 net Tel 82 31 852 4070 Fax 82 31 852 4656 ...

Reviews: