After inserting your simcard into the Auto-Dialer turn the unit on and wait until you see the

LED is on. This will indicate that you have a mobile signal and the unit is

ready for use.

You will now need to send a text with the contact number

Note - To avoid confusion we have colour coded the hash (

#

) and the equals (

=

) symbols.

Ex a mp le : (

h a s h

) (1 o r 2 o r 3) (

e q u a ls 

) (p h o n e  n u mb e r) (

h a s h 

)

then send this as a text to the simcard number of your unit

then send this as a text to the simcard number of your unit

then send this as a text to the simcard number of your unit

If you wish to cancel a number follow this example

Ex a mp le : (

h a s h

) (1 o r 2 o r 3) (

e q u a ls

) (DELETE) (

h a s h 

)

Then send this as a text to the simcard number of your unit

Please send one message at a time and wait for the Auto Dialler to send you back the text
Acknowledgement ‘NUMBER STORED’  before you try to add another number.

Below is a notepad to help you remember the numbers that you have saved to your
unit in the event you need to modify or delete in the future.

#

1=_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 

#

#

2= _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 

#

#

3=_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 

#

Page 4

Summary of Contents for IR BEAM

Page 1: ...PAGE 1 MODEL P I R I R B E A M 2G 3G PIR IR BEAM Detector ...

Page 2: ...red for outside installation and has passed testing in high temperature and below freezing conditions GSM Frequency Quad band fre 850 900 1800 1900 3G Model 2100 Mhz Power Supply Voltage 9 24 volts DC 1 Amp Max Current used in standby mode 60mA Max IP 65 Enclosure rating for outside installation 8 Amp Relay Output Micro 2G or 3G Simcard No land line required Dimensions L150 x W90 x H45mm Dimension...

Page 3: ...ou will receive a text telling you a signal strength score between 0 up to 30 we strongly recommend that you place the unit where you can receive a signal strength score of at least 10 You will find that with a score of less than 10 the unit will be unreliable Page 3 Slide the simcard into the holder making sure that the clipped corner of the simcard lines up with the clipped corner of the simcard...

Page 4: ...as a text to the simcard number of your unit then send this as a text to the simcard number of your unit If you wish to cancel a number follow this example Example hash 1 or 2 or 3 equals DELETE hash Then send this as a text to the simcard number of your unit Please send one message at a time and wait for the Auto Dialler tosend you back the text Acknowledgement NUMBERSTORED before you try to add ...

Page 5: ...text message The unit will reply back call on To disarm call alerts please send the text message If the call function has been set to you will receive a text message and shortly after a phone call Page 5 You can now change the alarm message for inputs 1 2 to your own choosing To change the message send the text command as follows MESS1 YOUR MESSAGE Input 1 Detected Input 1 MESS2 YOUR MESSAGE Alarm...

Page 6: ...ct and Auto Reset Input 2 Alarm Detect Input 1 The unit Is always armed and will trigger when the movement is detected it will automatically reset after 20 Seconds when no movement is detected you will receive a text message INPUT DETECTED Input 2 If you decide to use Input 2 you will need to set the alarm to ON by sending a text message ALARM ON this will activate the alarm When movement is detec...

Page 7: ...itoring and flood control Fridges Fish Tanks Farming equipment and security Dipswitch settings Dipswitch 1 ON 3G Selected OFF 2G Selected Dipswitch 2 ON Relay Mode on OFF Relay Mode off CALL TEXT CALL ONLY INPUT 2 ONLY To reset the unit back to factory settings you will need to send a text message RESET Warning this will reset all of your parameters only send a reset command when necessary The gre...

Page 8: ...larm system The relay can be manually activated by text message commands or it can be set to pulse for 20 seconds when an input has been activated refer to page 6 PAGE 8 Please make sure you supply a 9 24 volts DC from the battery terminals via a 2 amp fuse for alarm panel installations For more technical support please browse the FAQ s on our website Alternatively email our technical support team...