background image

 

 

5

make fir, it maybe the trigger has out of work. Please replace the parts according to 
the above method to obviate trouble. 

 

Exchange Xenon Lamp 

 

Step1: Take off the lamp head cover. Take off the 10 pieces six screws with 
hexangular screwdriver on the lamp head cover. 
 
Step2: Take off the epoxy board. Take off the 10 pieces hexangular screw with 
hexangular screwdriver on the epoxy board. Do not put much pressure when pulling, 
otherwise will snap the power line of fan. 
 
Step3: Take off nut M13 on the Xenon lamp head (anode) and then take off anode 
line, follows take off nut M13 on the end of xenon lamp (cathode) and then take off 
cathode line. During take off then xenon lamp, must hold the lamp in hand 
immobility. Do not let the lamp fall down or make any ram otherwise the lamp will 
break up and influence the cleaning inside the lamp box. 
 
Step4: Set the xenon lamp or the light head, epoxy board and light head cover 
according to the contradictorily step. 
 
Step5: Set the case of light head at original situation. 
 
 

Announcement 

 

When we delivery the goods out of factory, it is function is goods and package is 
well. All users must obey all noted attentions and operate rules. We won’t sere free of 
charge repair if the destroy be caused by your own wrong operation. All problems 
which be caused by not operate accord the user manual also not the duty of 
distributor. 
 

 
 
 
 
 
 

Summary of Contents for STAR SEARCH 4000

Page 1: ......

Page 2: ...iew It is very important to connect the earth line to earth Attention Do not separate the light by yourself Call technician in case the machine break down Set the light immobility and try to avoid strong shake or hit Prevent the dust into the product Make the vent pipe not be jammed while the light is working Check the power line whether be connected well before put on power Do not look at the lig...

Page 3: ...d connect well Must check the connect condition to avoid the resistance time Xenon lamp which higher than 2000w uses disassembly connect line Must use two spanners while install lamp One holds the copper gap Another turns the hexangular screw Any pressure or torsion not permitted Xenon ball lamp is super high voltage discharge lamp It must out of hit because there has high voltage before work and ...

Page 4: ...ol by strong wind during working Must pay attention to the back fan whether works well or not always Clean all optics lens and reflector at regular to increase the effect Cleaning times according to the operate frequency and usage situation We suggest to clean the outside systems per 20 days a time and inside optics lens per 60 days To keep luminous flux rate through clean the lamp with soft cloth...

Page 5: ...he end of xenon lamp cathode and then take off cathode line During take off then xenon lamp must hold the lamp in hand immobility Do not let the lamp fall down or make any ram otherwise the lamp will break up and influence the cleaning inside the lamp box Step4 Set the xenon lamp or the light head epoxy board and light head cover according to the contradictorily step Step5 Set the case of light he...

Page 6: ...2 18 24 and 28 light beams Light beam circles 80º 120º Range 1 5 Km Pan 110º Tilt 40º INGRESS PROTECTION IP44 POWER SUPPLY 4000W 220V AC optional 110V DIMENSIONS Physical dimension L25xW22xH49 inches L640xW560xH1240mm Gross dimension L35xW29xH57 inches L890xW740xH1450 mm WEIGHT Physical weight 66 Kg 145 Lb Gross weight in one flight case 116 Kg 255 Lb ...

Page 7: ...o explode If the lamp is accidentally touched clean it immediately with a soft cloth and isopropyl alcohol CH CH0H o Clean the lens and dichroic filters on a regular basis Do not use any type of solvent since it may damage the fixture just use a clean cloth It is not recommended to use the fixture for more than 4 hours Continuous use will shorten the life of the lamp o Clean your fixture on a regu...

Page 8: ...estrike Unit is producing unexpected results o Check DMX starting address on the fixture and console match o Verify that the last fixture on the link is terminated Unit is not responding to console o Verify that the fixture has the correct DMX address o Check and replace data cables o Verify that the last fixture on the link is terminated Unit is not moving o Check if the power supply is suitable ...