2. Difficulties during operation
Situation
Cause
Solution
The engine does
not reach the
speed
Choke is in "COLD START" position, the
exhaust system is blocked no air supply,
moving elements worn, ignition spark
weak too large valve clearance, cylinder
head sooty
Open choke, replace exhaust system
Check or replace ignition coil, adjust
flywheel, spark plug
Operating
materials are
leaking
Lines to carburetor blocked Spark plug
spacing incorrect
Replace lines and carburetor Adjust
gap dimension
Motor-
Noises
Wrong choke position,
Camshaft damaged
Check/replace camshaft
Carburetor
leaking
Failure of the check valve on the tank cap
Replace the fuel filler cap
Carburetor gasket is worn out
Replace carburetor or gasket
If no troubleshooting solves the problem, please contact the FUXTEC
customer service. Only use original parts approved by the
manufacturer. Otherwise, there is a risk of danger.