ELI43-CP
User’s Manual
02/13/17
Copyright ©2017, Future
Designs, Inc.
Page
8
of
12
To verify that the ELI43-CP unit is correctly powered you may check the 12VDC input with a Fluke
meter or scope by probing the +12V and GND contacts, shown below. Please verify that the +12VDC
is present, is within the +/- 5% tolerance and is free from excessive noise or AC ripple.
Note: If using an input that is within the acceptable range of Rev 3.0 ELI43-CP boards, +5VDC
to +24VDC (+/- 5%), please keep in mind that the 12V Test points should be at the voltage of
your chosen power supply (5-24VDC).
Figure 4. ELI43-CP Power Test Points
9.0
Extended Display Information Data (EDID)
ELI uses Extended Display Identification Data (EDID) for automatic configuration with many
operating systems. You can find out more on our website at
http://www.teamfdi.com/edid/
.