INSTRUCTIONS FOR USE - futudent
1
Thank you for purchasing the futudent product.
Novocam Medical Innovations Oy (Novocam) is selling futudent for dental
market.
These apparatuses are intended by the manufacturer to be used by qualified
healthcare professionals to capture videos and pictures during dental and
medical treatments for the purpose of documentation, providing additional
information for diagnosis, following and evaluating changes of medical
conditions and for educational purposes in dental and medical field.
Important Safety Information
Warnings
!
The device must only be used for the intended purpose described above
only.
!
The camera must not be connected to life-supporting computers or
devices.
!
Disassembling the device is prohibited.
!
Do not make any changes, modifications or alterations to the device.
!
Do not change lenses in vicinity of patients. If lens needs to be changed or
focused make sure the camera is not above the patient due to the risk of
lens drop.
!
Do not leave loose cables on the floor. Cables on the floor should be
protected by cable shields or otherwise sufficiently protected.
!
Ensure all components or parts are attached before use:
Check that the camera lens is attached properly to the camera. Do
not turn lens too much because it might fall out. The camera will be
completely out of focus well before the lens detaches. If the lens is
detached, insert it carefully so that the threads are not damaged.
Remove lens cover before attaching the camera to the overhead
light or to the loupes.
Adjust the lens focus
before the operation / treatment.
Make sure that the camera is attached firmly to the loupes,
headband or overhead light with no wiggling.
When having camera mounted to the loupe, attach the cable spiral
to the loupes before the operation.
Check that the device is clean. If not, clean the device carefully as
described below.
The computer used for shooting videos must be placed at least
2m/7ft. from the patient.
If the device or its components function abnormally, stop using the
device as soon as possible, and contact the seller or manufacturer.
Safety precautions
!
Do not use the device outdoors.
!
Protect the device from fluids.
!
Do not use in direct sunlight, dust, salt, magnetic fields, chemicals, gases,
radiation, electrostatic discharge, acceleration, thermal ignition sources or
to adverse environmental conditions.
!
Store the device in specified temperatures only.
!
Keep cables away from fire or severe heat (over 70°C/158°F)
!
Sometimes camera color settings are inaccurate, or monitors / screens
are not presenting colors correctly and you need to adjust color
settings.(see 7.5.)
!
Camera’s image quality can look low due to insufficient lighting
conditions. Ensure sufficient amount of light. (see 7.6.)
!
If you notice that device gets hot, has an odor, or changes color or shape,
disconnect device immediately. DO NOT USE THE DEVICE!
Working condition precautions
!
Do not use the device, when working temperature is above 30°C/86°F or
when humidity is over 85 %.
!
Do not handle the device by the cable.
!
The camera must not be exposed to pressure, shock, vibration, or other
mechanical stress.
!
Do not use the camera with wet hands or wet gloves.
!
Do not spray the device with water/detergent.
!
Do not sink the device in any liquid.
!
Do not use the device if the camera overheats (over 50°C/120°F),
disconnect it from the computer and allow it to cool for one hour. If the
device becomes hot again in a relatively short period (1-5min), do not use
it and contact the seller or manufacturer.
!
Check the cable visually from time to time. If the surface of the cable is
damaged, contact the nearest local support or manufacturer.
!
Storage condition precautions
!
Keep the device in the temperature between 5° to 50°C (41F to 122°F).
!
Keep the room relative humidity between 10% - 85% (non-condensing).
If Futulight is purchased (optional accessory)
!
Do not use Futulight when it is connected to a power supply.
!
Charge Futulight before the operation.
NOTE: It is advised that Futulight is not the primary light to use during
the treatment / recording. An alternative light source is recommended in
case the Futulight battery is running out.
!
Do not charge Futulight battery on flammable materials, such as a
bed, couch or on paper.
!
Do not overcharge your device; unplug the device when fully
charged.
!
Never keep li-ion batteries near heat sources or in high
temperatures, such as direct sunlight, radiators or laptops.
!
Do not let battery get wet or to be exposed to liquids.
!
Store the battery in a secure, dry, and cool place, and away from
flammable materials. Keep batteries separate from metal objects.
!
If you notice signs that the battery has a problem, such as
overheating, odor, leaks, or change in color/shape, shut off the
device and move it away from things that can catch fire and contact
the seller or manufacturer..
Important
If the camera
stops working for any reason during the treatment,
continue the treatment as you would do without the camera
The device is not compatible with other devices that are not
mentioned in this document. Connecting the device to any external
device, such as electricity, gas or hydraulic and pneumatic source, is
prohibited.
Equipment must not be brought into contact with the patient or
brought to the sterile area.
Do not touch the lens during
treatments in order to keep sterile.
Do not touch the camera during the treatments
Liability notes
This instruction and the accompanying documents should be thoroughly
read before using the device. Novocam Medical Innovations Oy is not
responsible for any injury, damage or malfunction arising from the use or
inability to use any information, apparatus, method or process disclosed
in this document.
1.
Know Your Device
1.1 Products Specification
proCam is the first miniature 4K (2160p) dental camera on the market
and its 13-megapixel sensor captures both 4K video and hi-res still photos
from either loupes or the overhead treatment light.
Technical specifications for proCam
Resolution: 13 MPix / 4K & 1080p (video)
Full aluminum body
Weight: 29 grams (1.02 ounces)
Dimensions: 32 x 23 x 29 mm (1.27 x 0.91 x 1.14 inches)
Digital zoom (up to 3x)
Optics changeable lenses with manual focus
Hands free operations with USB foot pedal
Mounting options:
•
Loupe mount (universal/loupe specific attachments)
•
Overhead light or Headband
•
Gooseneck/flexible arm
USB 2 connection with detachable cable (USB micro connector)
Camera is fully powered through USB
Recording software: Win, Mac and Android
5 software licenses included/unit
Regulatory compliance:
o
MDR 2017/745, classification I
eduCam - is a 1080p (fullHD) 30 FPS multi-mount camera designed for
healthcare professionals.
Technical specifications for eduCam
Resolution: 3.4MPix / Full HD (video)
Full aluminum body
Weight: 29 grams (1.02 ounces)
Dimensions: 32 x 23 x 29 mm (1.27 x 0.91 x 1.14 inches)
Digital zoom (up to 2.5x)
Optics: Changeable lenses with manual focus
Hands free operations with USB foot control
Mounting options:
•
Loupe mount (universal/loupe specific attachment)
•
Overhead light to Headband
•
Gooseneck/flexible arm
USB 2 with detachable cable (USB micro connector)
Camera is fully powered through USB
Recording software: Win, Mac and Android
5 software licenses included/unit
Regulatory compliance: