background image

INSTRUCTIONS FOR USE  -  futudent 

 

 

 

 

Thank you for purchasing the futudent product. 

 

Novocam Medical Innovations Oy (Novocam) is selling futudent for dental 

market. 

 

These apparatuses are intended by the manufacturer to be used by qualified 

healthcare professionals to capture videos and pictures during dental and 

medical treatments for the purpose of documentation, providing additional 

information for diagnosis, following and evaluating changes of medical 

conditions and for educational purposes in dental and medical field.

 

 

Important Safety Information 

Warnings 

  

 

!

 

The device must only be used for the intended purpose described above 

only. 

!

 

The camera must not be connected to life-supporting computers or 

devices. 

!

 

Disassembling the device is prohibited. 

!

 

Do not make any changes, modifications or alterations to the device. 

!

 

Do not change lenses in vicinity of patients. If lens needs to be changed or 

focused make sure the camera is not above the patient due to the risk of 

lens drop. 

!

 

Do not leave loose cables on the floor. Cables on the floor should be 

protected by cable shields or otherwise sufficiently protected. 

!

 

Ensure all components or parts are attached before use: 

 

Check that the camera lens is attached properly to the camera. Do 

not turn lens too much because it might fall out. The camera will be 

completely out of focus well before the lens detaches. If the lens is 

detached, insert it carefully so that the threads are not damaged. 

 

Remove lens cover before attaching the camera to the overhead 

light or to the loupes.  

 

Adjust the lens focus 

before the operation / treatment

 

Make sure that the camera is attached firmly to the loupes, 

headband or overhead light with no wiggling. 

 

When having camera mounted to the loupe, attach the cable spiral 

to the loupes before the operation. 

 

Check that the device is clean. If not, clean the device carefully as 

described below. 

 

The computer used for shooting videos must be placed at least 

2m/7ft. from the patient.  

 

If the device or its components function abnormally, stop using the 

device as soon as possible, and contact the seller or manufacturer. 

 

Safety precautions  

 

!

 

Do not use the device outdoors. 

!

 

Protect the device from fluids. 

!

 

Do not use in direct sunlight, dust, salt, magnetic fields, chemicals, gases, 

radiation, electrostatic discharge, acceleration, thermal ignition sources or 

to adverse environmental conditions. 

!

 

Store the device in specified temperatures only. 

!

 

Keep cables away from fire or severe heat (over 70°C/158°F) 

!

 

Sometimes camera color settings are inaccurate, or monitors / screens 

are not presenting colors correctly and you need to adjust color 

settings.(see 7.5.) 

!

 

Camera’s image quality can look low due to insufficient lighting 

conditions. Ensure sufficient amount of light. (see 7.6.)

 

!

 

 

 

If you notice that device gets hot, has an odor, or changes color or shape, 

disconnect device immediately. DO NOT USE THE DEVICE! 

 

Working condition precautions 

 

!

 

Do not use the device, when working temperature is above 30°C/86°F or 

when humidity is over 85 %. 

!

 

Do not handle the device by the cable. 

!

 

The camera must not be exposed to pressure, shock, vibration, or other 

mechanical stress. 

!

 

Do not use the camera with wet hands or wet gloves. 

!

 

Do not spray the device with water/detergent. 

!

 

Do not sink the device in any liquid. 

!

 

Do not use the device if the camera overheats (over 50°C/120°F), 

disconnect it from the computer and allow it to cool for one hour. If the 

device becomes hot again in a relatively short period (1-5min), do not use 

it and contact the seller or manufacturer. 

!

 

Check the cable visually from time to time. If the surface of the cable is 

damaged, contact the nearest local support or manufacturer. 

!

 

 

Storage condition precautions 

 

!

 

Keep the device in the temperature between 5° to 50°C (41F to 122°F). 

!

 

Keep the room relative humidity between 10% - 85% (non-condensing). 

 

If Futulight is purchased (optional accessory) 

 

!

 

Do not use Futulight when it is connected to a power supply. 

!

 

Charge Futulight before the operation.  

NOTE: It is advised that Futulight is not the primary light to use during 

the treatment / recording. An alternative light source is recommended in 

case the Futulight battery is running out. 

!

 

Do not charge Futulight battery on flammable materials, such as a 

bed, couch or on paper. 

!

 

Do not overcharge your device; unplug the device when fully 

charged. 

!

 

Never keep li-ion batteries near heat sources or in high 

temperatures, such as direct sunlight, radiators or laptops. 

!

 

Do not let battery get wet or to be exposed to liquids. 

!

 

Store the battery in a secure, dry, and cool place, and away from 

flammable materials. Keep batteries separate from metal objects. 

!

 

If you notice signs that the battery has a problem, such as 

overheating, odor, leaks, or change in color/shape, shut off the 

device and move it away from things that can catch fire and contact 

the seller or manufacturer.. 

 

Important 

 

If the camera 

stops working for any reason during the treatment, 

continue the treatment as you would do without the camera 

 

The device is not compatible with other devices that are not 

mentioned in this document. Connecting the device to any external 

device, such as electricity, gas or hydraulic and pneumatic source, is 

prohibited. 

 

Equipment must not be brought into contact with the patient or 

brought to the sterile area. 

Do not touch the lens during 

treatments in order to keep sterile. 

 

Do not touch the camera during the treatments 

 

Liability notes 

This instruction and the accompanying documents should be thoroughly 

read before using the device. Novocam Medical Innovations Oy is not 

responsible for any injury, damage or malfunction arising from the use or 

inability to use any information, apparatus, method or process disclosed 

in this document.  

 

1.

 

Know Your Device 

 

1.1  Products Specification 

 

proCam is the first miniature 4K (2160p) dental camera on the market 

and its 13-megapixel sensor captures both 4K video and hi-res still photos 

from either loupes or the overhead treatment light.  

 

Technical specifications for proCam 

 

Resolution: 13 MPix / 4K & 1080p (video) 

 

Full aluminum body 

 

Weight: 29 grams (1.02 ounces) 

 

Dimensions: 32 x 23 x 29 mm (1.27 x 0.91 x 1.14 inches) 

 

Digital zoom (up to 3x) 

 

Optics changeable lenses with manual focus 

 

Hands free operations with USB foot pedal 

 

Mounting options: 

 

Loupe mount (universal/loupe specific attachments) 

 

Overhead light or Headband 

 

Gooseneck/flexible arm 

 

USB 2 connection with detachable cable (USB micro connector) 

 

Camera is fully powered through USB 

 

Recording software: Win, Mac and Android 

 

5 software licenses included/unit 

 

Regulatory compliance: 

o

 

MDR 2017/745, classification I  

eduCam - is a 1080p (fullHD) 30 FPS multi-mount camera designed for 

healthcare professionals. 

 

Technical specifications for eduCam 

 

Resolution: 3.4MPix / Full HD (video) 

 

Full aluminum body 

 

Weight: 29 grams (1.02 ounces) 

 

Dimensions: 32 x 23 x 29 mm (1.27 x 0.91 x 1.14 inches) 

 

Digital zoom (up to 2.5x) 

 

Optics: Changeable lenses with manual focus 

 

Hands free operations with USB foot control 

 

Mounting options: 

 

Loupe mount (universal/loupe specific attachment) 

 

Overhead light to Headband 

 

Gooseneck/flexible arm 

 

USB 2 with detachable cable (USB micro connector) 

 

Camera is fully powered through USB 

 

Recording software: Win, Mac and Android 

 

5 software licenses included/unit 

 

Regulatory compliance:  

Summary of Contents for Novocam

Page 1: ...er Check the cable visually from time to time If the surface of the cable is damaged contact the nearest local support or manufacturer Storage condition precautions Keep the device in the temperature between 5 to 50 C 41F to 122 F Keep the room relative humidity between 10 85 non condensing If Futulight is purchased optional accessory Do not use Futulight when it is connected to a power supply Cha...

Page 2: ...th the foot control The camera is always available when connected to PC and SW is running to get high quality documentation of any procedure the moment it s needed Put the self adhesive light connector in an optimal location aligned with the light NOTE Do not stick on a surface heating over 50 C as it will melt the glue on the connector Attach cables to the arm with the cable clips Reinstalling re...

Page 3: ...d videos are saved locally on your computer in the predefined folders Photos and videos can also be uploaded to the Futudent cloud for secure sharing with patients or colleagues futudent software All videos are recorded in h 264 mp4 format Referring to 2 2 2 2 6 Download the futudent App to Android mobile devices Search for Futudent in the App Store Google Play Store Click install and follow the p...

Page 4: ...you do not have a Futudent account select Register in the top of the webpage and follow the prompts to set up your Futudent account Click Upload button in the top right corner of your Futudent homepage Fill in the Title Description optional and Category of the recording you wish to upload Click Choose file to browse your computer and select the file you wish to upload Click Upload 3 3 2 Share reco...

Page 5: ...vocam the Product and or Accessory should be properly packed for shipping 6 Available accessories Novocam provides also following futudent optional accessories They are available at our company web shop https www futudent com shop 6 1 Camera Lenses Lenses are designed to be used in operatory rooms and they offer exceptional depth of view Available lenses 8mm lens UHD 5MP 1 1 5X magnification wide ...

Page 6: ...ast hue saturation white balance can be done in the camera control panel in the software color adjustment to monitors can be adjusted on the monitor or operating system Reference color samples are recommended to be used to ensure color accuracy 7 6 Camera s image quality is low Camera s image quality can look low due to insufficient lighting conditions A solution In general good quality recordings...

Reviews: