3. HOW TO SET UP THE EQUIPMENT
3-13
Transducer Setup menu
*:
This item is only available for DFF3 users.
When [Transducer Setup Type] is set to [Model] and connected to DFF3
When [Transducer Setup Type] is set to [Manual]
Menu item
Description
Options
(setting range)
[Transducer Setup
Type]
Select the type of transducer connected.
When the connected sounder is a DFF1-UHD and the
transducer has a compatible TDID, [TDID] is automati-
cally selected.
• [Manual]: Manually set up the transducer.
• [Model]: Select the appropriate transducer model
(for FURUNO or AIRMAR transducers)
• [TDID]: Select the TDID for the transducer (for
AIRMAR transducers with a TDID)
[Manual],
[Model],
[TDID]
[Model Number]
Select the appropriate model number from the list.
Note:
Only available when Transducer Setup Type is set to [Model].
[High Frequency Min]
Display the high frequency minimum.*
[High Frequency Max] Display the high frequency maximum.*
[Low Frequency Min]
Display the low frequency minimum.*
[Low Frequency Max] Display the low frequency maximum.*
[Reset Default Set-
tings]
Reset the Transducer Setup menu settings to default.
[OK], [Cancel]
Menu item
Description
Options
(setting range)
[High Frequency]
Select the model and frequency (HF & LF) of the connected
transducer from the appropriate drop down menu.
[Low Frequency]
Menu item
Description
Options
(setting range)
[High Frequency (KHz)]
Set the kHz frequency for high frequency. Setting ranges vary
depending on the transducer connected.
[Transducer Power HF]
Set the transmission power for high frequency.
Note 1:
This menu item is available only for
DFF1, DFF1-UHD, BBDS1 and internal fish
finder users.
Note 2:
For DDF1-UHD users, when the con-
nected transducer TDID is not supported by the
DFF1-UHD, the setting is fixed as [1000].
[600], [1000]
Band Width (HF)
Set the bandwidth for high frequency.
Note:
This item is only available for DFF3 users
when the Transducer type is set to [Manual].
[10] to [100]
[Low Frequency (KHz)]
Set the kHz frequency for low frequency. Setting ranges vary
depending on the transducer connected.
Summary of Contents for TZTL12F
Page 34: ...2 WIRING 2 12 This page is intentionally left blank ...
Page 52: ...APPENDIX 1 INSTALLATION OF TEMPERATURE SENSORS AP 2 ...
Page 53: ...APPENDIX 1 INSTALLATION OF TEMPERATURE SENSORS AP 3 ...
Page 54: ...APPENDIX 1 INSTALLATION OF TEMPERATURE SENSORS AP 4 ...
Page 55: ...APPENDIX 1 INSTALLATION OF TEMPERATURE SENSORS AP 5 ...
Page 59: ...D 1 ...
Page 60: ...D 2 ...
Page 61: ...27 Aug 2014 H MAKI D 3 ...
Page 62: ...27 Aug 2014 H MAKI D 4 ...
Page 63: ...27 Aug 2014 H MAKI D 5 ...
Page 64: ...27 Aug 2014 H MAKI D 6 ...
Page 65: ...D 7 ...
Page 66: ...1 Sep 2014 H MAKI D 8 ...