2. WIRING
2-4
2.5
MULTI Cable
Use the MULTI cable for the NMEA0183 equipment, external buzzer to supply power
to the CAN bus. The connector has 9 wires and connector (SMP-11V). Use the table
below for reference and connector (SMD-11V, local supply) when connecting the
MULTI cable.
2.5.1
How to set up NMEA0183 data output
Note:
To set up data input from NMEA0183 equipment, see "NMEA0183 equipment
1. Tap the [Home] icon (
) to show the home screen and display mode
settings.
2. Tap [Settings], then drag the menu to show [Initial Setup]. Tap [Initial Setup].
3. Drag the menu to show [NMEA0183 Output], then tap [NMEA0183 Output].
4. Tap [Baud Rate] to set the output baud rate. Available options are [4,800], [9,600]
and [38,400].
5. Tap the appropriate setting then tap the icon.
6. Tap [NMEA-0183 Version] to set the version. Available options are [1.5], [2.0] and
[3.0].
7. Tap the appropriate setting then tap the icon.
8. Select the appropriate sentences to output, then tap the flipswitch to set the
sentence to [ON].
9. Tap the [Close] icon at the top right of the screen to close the menus.
Wire color
Function
Remark (Port No.)
White
NMEA-TD-A
NMEA0183 Output
Blue
NMEA-TD-B
Gray
EXT_BUZZER
External buzzer ON/OFF
Red
+12 V
External buzzer power (12 V)
Orange
EVENT_SW
Event switch (MOB, etc.)
Black
GND
Grounding
Purple
POWER_SW
Power switch
Brown
DC_N
Black
DRAIN
Grounding