TECDIS Installation Manual
Page 51
3.7.2 Default values new route
The values in this area will be used as the default values for the parameters specified when
planning a new route.
Speed kn
The default planned speed in knots for new route legs.
Lane x 0.01 NM
The default planned lane width for new route legs, expressed as
hundredths
of
a
nautical
mile.
(For example, if the value specified
here is 10, the default lane width would be 0.1 NM.)
Turn radius x 0.1 NM
The default planned turn radius for new route legs, expressed as
tenths of a nautical mile. (For example, if the value specified
here
is
5,
the
default
turn radius would be 0.5 NM.)
3.7.3 Other settings
Anschütz AP 20205 PLUS at COM
Specify the COM port that the Raytheon Anschütz AP 2025 PLUS autopilot is connected to.
Min. allowed turn radius x 0.01 NM
This setting specifies the minimum turn radius allowed, expressed as hundredths of a nautical
mile. This value should be determined during vessel sea trials.
Max. allowed WOL distance x 0.01 NM
This setting specifies the maximum value allowed for operator selected Wheelover Line (WOL)
distance, expressed as hundredths of a nautical mile.
Max Remote Control ROT
This setting specifies the maximum rate of turn (ROT) value allowed in the autopilot remote
control panel in TECDIS, expressed as degrees per minute.
WP warning and alarm time
This setting controls how long before a waypoint warnings and alarms are generated.
Alarm limit difference primary and secondary heading
This setting controls the number of degrees the primary and secondary heading sensor values can
differ before an alarm is generated. If the two heading sensors differ by more than this value, an
alarm is generated in TECDIS.
Alarm limit difference primary and secondary position x 0.01 NM
This setting controls the distance allowed between the two position sensors before an alarm is
generated, expressed in hundredths of a nautical mile. If the distance between the positions
reported by the two position sensors is larger than this value, an alarm is generated in TECDIS.
Summary of Contents for TECDIS
Page 8: ...TECDIS Installation Manual Page 7 Installation Overview...
Page 18: ...TECDIS Installation Manual Page 17 Outline dimensions for HT 405P4 TEL A1 All figures in mm...
Page 22: ...TECDIS Installation Manual Page 21 Furuno RCU 018 Control Unit outline Flush mount...
Page 32: ...TECDIS Installation Manual Page 31 2 1 Wiring diagram HT 405P4 TEL A1...
Page 33: ...TECDIS Installation Manual Page 32 2 2 Signal distribution diagram internal data flow...
Page 35: ...TECDIS Installation Manual Page 34 2 4 Ethernet connectors and cable...
Page 36: ...TECDIS Installation Manual Page 35 2 5 Other connectors...
Page 64: ...TECDIS Installation Manual Page 63 This page is intentionally left blank...
Page 75: ...TECDIS Installation Manual Page 74 6 4 Installation Notes...
Page 76: ...TECDIS Installation Manual Page 75...
Page 79: ...TECDIS Installation Manual Page 78 This page is intentionally left blank...