TECDIS Installation Manual
Page 47
3.5.5 Monitor Calibration and Test
This area provides information on the current
monitor calibration status, means to update the
monitor calibration and diagnostics for testing the
serial connection to the monitor.
Proper monitor calibration is needed to ensure
correct chart colors and symbols.
To calibrate the monitor first attempt automatic
calibration by pressing the “Identify Monitor and
Load Automatic Calibration” button. If this is not
successful, calibrate manually by pressing the
“Manual Calibration: Load Calibration File…”
button and selecting the correct calibration file
matching the monitor. If such a file cannot be
located, this can be obtained from your TECDIS
support provider.
Monitor Calibration Status:
Indicates the current status of monitor calibration. The possible
values seen here and steps to rectify any problems are as follows:
Status Message
Action
No serial line to monitor!
Connect the monitor to a serial port in accordance with chapter
2 and 3.2.
Calibration not performed!
Perform automatic or manual calibration as outlined below.
Wrong manual calibration file loaded!
The manual calibration file loaded does not match the
connected monitor. Obtain the correct calibration file from your
TECDIS support provider and repeat manual calibration.
Monitor contains wrong automatic calibration!
The monitor does not contain the correct monitor calibration
files. Contact your TECDIS support provider.
Automatic calibration loaded but not verified
Calibration has been successfully performed.
Verify correct
calibration by comparing the monitor model specified in
“Calibration Name” to the monitor model label.
Manual calibration loaded but not verified
Automatic calibration loaded and verified
Calibration has been successfully performed and verified.
Manual calibration loaded and verified
Calibration Name:
Indicates the name of the currently loaded manual or automatic calibration.
Monitor Type:
Indicates the monitor model name as reported by the monitor during the last
automatic calibration process.
Identify Monitor and Load Automatic Calibration:
Initiates automatic identification of
monitor type and attempts to load automatic calibration data from the monitor.
Manual Calibration: Load Calibration File…:
Allows the operator to manually load a monitor
calibration file.
Monitor Connection Tests…:
Provides access to tests to verify correct monitor serial
connection (buzzer test, backlighting adjustment tests and monitor identification test).
Summary of Contents for TECDIS
Page 8: ...TECDIS Installation Manual Page 7 Installation Overview...
Page 18: ...TECDIS Installation Manual Page 17 Outline dimensions for HT 405P4 TEL A1 All figures in mm...
Page 22: ...TECDIS Installation Manual Page 21 Furuno RCU 018 Control Unit outline Flush mount...
Page 32: ...TECDIS Installation Manual Page 31 2 1 Wiring diagram HT 405P4 TEL A1...
Page 33: ...TECDIS Installation Manual Page 32 2 2 Signal distribution diagram internal data flow...
Page 35: ...TECDIS Installation Manual Page 34 2 4 Ethernet connectors and cable...
Page 36: ...TECDIS Installation Manual Page 35 2 5 Other connectors...
Page 64: ...TECDIS Installation Manual Page 63 This page is intentionally left blank...
Page 75: ...TECDIS Installation Manual Page 74 6 4 Installation Notes...
Page 76: ...TECDIS Installation Manual Page 75...
Page 79: ...TECDIS Installation Manual Page 78 This page is intentionally left blank...