TECDIS Installation Manual
Page 11
TELchart TA3232-1 analog adapter.
Technical specifications:
Inputs:
32 digital inputs
32 analog input (24 x +/- 10VDC and 8 x 4-20mA )
Outputs:
RS422 output ar baudrate 4800,n,8,1 to Furuno VDR
Ethernet TCP/IP serverport at 192.168.0.60 : 2000
Ethernet UDP/IP broadcast at 0.0.0.0 : 2100
The placement of the modules in the box are.
[ADAM4051 #2] [A #4] [A #6]
[ADAM6520] [ADAM6500] [ADAM4051 #1] [A #3] [A #5]
From left to right as indicated in the picture
ADADM 6520 5 port industrial 10/100 Mb Ethernet switch w/auto direction sense.
ADADM 6500 WinCE processor
2 x ADADM 4051 á 8 x digital inputs
2 x ADADM 4017+ á 8 x analog inputs
2 x ADADM 4017+ á 8 x analog inputs (top one is 8 x 4-20mA inputs)
Powered from 12-30 VDC
Typical consumption 0.4A @24 VDC
Fuses: 2 x 1,6AT
Summary of Contents for TECDIS
Page 8: ...TECDIS Installation Manual Page 7 Installation Overview...
Page 18: ...TECDIS Installation Manual Page 17 Outline dimensions for HT 405P4 TEL A1 All figures in mm...
Page 22: ...TECDIS Installation Manual Page 21 Furuno RCU 018 Control Unit outline Flush mount...
Page 32: ...TECDIS Installation Manual Page 31 2 1 Wiring diagram HT 405P4 TEL A1...
Page 33: ...TECDIS Installation Manual Page 32 2 2 Signal distribution diagram internal data flow...
Page 35: ...TECDIS Installation Manual Page 34 2 4 Ethernet connectors and cable...
Page 36: ...TECDIS Installation Manual Page 35 2 5 Other connectors...
Page 64: ...TECDIS Installation Manual Page 63 This page is intentionally left blank...
Page 75: ...TECDIS Installation Manual Page 74 6 4 Installation Notes...
Page 76: ...TECDIS Installation Manual Page 75...
Page 79: ...TECDIS Installation Manual Page 78 This page is intentionally left blank...