background image

TECDIS Installation Manual 

 

Page 0 

 

A fully type approved Electronic Chart and 
Display Information System (ECDIS), 
certified by DNV. 

Installation Manual 

Software edition: 4.7.1 
Manual edition: 2.1 

Summary of Contents for TECDIS

Page 1: ...TECDIS Installation Manual Page 0 A fully type approved Electronic Chart and Display Information System ECDIS certified by DNV Installation Manual Software edition 4 7 1 Manual edition 2 1...

Page 2: ...on if the wrong type of battery is used for replacement Observe the following compass safe distances to prevent interference to a magnetic compass Standard compass Steering compass HT405P4 TEL A1 2 20...

Page 3: ...31 2 2 SIGNAL DISTRIBUTION DIAGRAM INTERNAL DATA FLOW 32 2 3 PROCESSOR CONNECTORS HT 405P4 TEL A1 33 2 4 ETHERNET CONNECTORS AND CABLE 34 2 5 OTHER CONNECTORS 35 CHAPTER 3 PARAMETER SETUP 36 3 1 SERVI...

Page 4: ...4 SHOW SHIP OUTLINE 55 4 2 5 COURSE VECTORS 55 4 2 6 WHEELOVER 55 4 3 OPERATIONAL PARAMETERS FOR AIS 56 4 3 1 DISPLAY FILTER RANGE AND TRACK 56 4 3 2 DISPLAY FILTER ALL TARGETS ACTIVE 56 4 3 3 DISPLAY...

Page 5: ...DIS Telchart ini if present Please note the following All position inputs to TECDIS from all external sensors must be in WGS 84 datum TECDIS shall be supplied by UPS uninterrupted power supply 220VAC...

Page 6: ...Annex 2 IMO Resolution A 694 17 Version 4 6 0 to 4 7 0 Marine Equipment Directive Module B MED B IMO Resolution MSC 74 69 Annex 2 IMO Resolution A 817 19 as amended by MSC 64 67 Annex 5 and by MSC 86...

Page 7: ...1 2 0 m video cable 1 9 m power cable Monitor JH 20T17 MMD 1 2 0 m video cable 1 9 m power cable Monitor JH 23T12 MMD 1 2 0 m video cable 1 9 m power cable Fan Regulation Kit JH KIT HT405P4TEL A1 1 T...

Page 8: ...TECDIS Installation Manual Page 7 Installation Overview...

Page 9: ...l RGB 15pin mini D SUB Input signal Multifunction AC power 115 VAC 60 Hz 230 VAC 50 Hz 100 W max Weight 13 5 kg Monitor JH 19T14 MMD 19 0 inch viewable image size Active matrix Thin Film Transistor Pi...

Page 10: ...Mechanically limited break resistant Cable 96 0 5 Power Consumption Idle 8mA Max 12mA Mechanical Specifications Dimensions Approximately 4 wide x 8 long Weight 1 3 lbs Body Material Glass filled Xenoy...

Page 11: ...y LCA110E which has capabilities of max 50VDC max 200mA Input connector 5 6 uses a current limited 6 8 Kohm resistor opto coupler MCT5211 Reset in at 10 30 VDC All input and outputs are electrically i...

Page 12: ...0 0 0 0 2100 The placement of the modules in the box are ADAM4051 2 ADAM4017 4 ADAM4017 6 ADAM6520 ADAM6500 ADAM4051 1 ADAM4017 3 ADAM4017 5 From left to right as indicated in the picture ADADM 6520...

Page 13: ...d 3 Locate the unit out of direct sunlight and away from heat sources because of heat that can build up inside the cabinet 4 Locate the equipment away from places subject to water splash and rain 5 Le...

Page 14: ...r JH 20T17 MMD Dimensions might be shown with or without decimals and indicated as mm inches Tolerance on drawings is 1mm For accurate measurements check relevant DWG file as obtainable from http www...

Page 15: ...r JH 19T14 MMD Dimensions might be shown with or without decimals and indicated as mm inches Tolerance on drawings is 1mm For accurate measurements check relevant DWG file as obtainable from http www...

Page 16: ...r JH 23T12 MMD Dimensions might be shown with or without decimals and indicated as mm inches Tolerance on drawings is 1mm For accurate measurements check relevant DWG file as obtainable from http www...

Page 17: ...easy access to front doors of the processor It must be possible to open CD drawer of processor without obstructions 6 The power switch shall be easily to access front of processor may be flush mounte...

Page 18: ...TECDIS Installation Manual Page 17 Outline dimensions for HT 405P4 TEL A1 All figures in mm...

Page 19: ...ix the KB fixing plate to the bottom of the control unit 2 Attach three cushions to the bottom of the control unit 3 Fix it to a desired location with self tapping screws local supply Fixing without K...

Page 20: ...TECDIS Installation Manual Page 19 Furuno RCU 018 Control Unit outline Desktop mount All figures in mm...

Page 21: ...TECDIS Installation Manual Page 20 Furuno RCU 018 Control Unit outline Desktop mount with bracket All figures in mm...

Page 22: ...TECDIS Installation Manual Page 21 Furuno RCU 018 Control Unit outline Flush mount...

Page 23: ...y from heat sources because of heat that can build up inside the cabinet 3 Locate the equipment away from places subject to water splash and rain 4 Determine the mounting location considering the leng...

Page 24: ...y adding strength to console where the processor is about to be installed 2 Locate the unit away from heat sources because of heat that can build up inside the cabinet 3 Locate the equipment away from...

Page 25: ...ion Manual Page 24 Outline dimensions for alarm interface TEA 01 Length 125 mm Width 55 mm Heigth 40 mm Cable length 1400 mm Outline dimensions for loudspeaker DNH HP6 with bracett Loudspeaker cable l...

Page 26: ...TECDIS Installation Manual Page 25 Outline dimensions for loudspeaker DNH HPS6 for flush mount Loudspeaker cable length is 500 mm...

Page 27: ...TECDIS Installation Manual Page 26 Outline dimensions for analog interface connection distribution box TA3232 1 Length 500 mm Width 500 mm Heigth 210 mm...

Page 28: ...TECDIS Installation Manual Page 27 Outline dimensions for MOXA RS 422 interface box MOXA OPT8F Dimensions for box 247 x 108 x 35 mm DB 62 cable length 1500 mm...

Page 29: ...US must be supplied with the same set of heading and log sensor inputs On vessels where the steering system does not provide a freeze rudder function and maintained voltage is required for maintaining...

Page 30: ...on 1 2 Automatic correction for speed and latitude error 1 3 Automatic switching to back up gyro when selected gyro fails 1 4 Compliance with requirements to gyro system information system in use as s...

Page 31: ...tribution During installation actual need for signal distribution must be verified by installer depending on signals available and actual hardware installation on the specific vessel RS422 Box with 8x...

Page 32: ...TECDIS Installation Manual Page 31 2 1 Wiring diagram HT 405P4 TEL A1...

Page 33: ...TECDIS Installation Manual Page 32 2 2 Signal distribution diagram internal data flow...

Page 34: ...nnected to COM1 COM3 and COM4 via an RS232 RS422 interface such as AD400 We advise that only COM1 COM3 and COM4 are used to connect AIS via an RS232 RS422 interface If optional speaker connectors HT00...

Page 35: ...TECDIS Installation Manual Page 34 2 4 Ethernet connectors and cable...

Page 36: ...TECDIS Installation Manual Page 35 2 5 Other connectors...

Page 37: ...lotter off you must insert the USB service key memory dongle before you exit TECDIS When this service key is connected to the chart plotter the chart plotter will not be turned off when you exit TECDI...

Page 38: ...llision when there is an attempt to use the same port for multiple conflicting functions the affected ports are marked with red color IP ports TECDIS has 12 COM ports and 4 IP ports For each IP port t...

Page 39: ...ng indicator in this area will flash green The indicators are for COM ports 1 12 in increasing order from left to right 3 2 5 Received data In this area you can see the data that are being received fr...

Page 40: ...NS GNSS Fix Data Receive HDT Heading True Receive MTW Water temperature Receive MWV Wind Speed and Angle Receive OSD Own Ship Data Receive RMB Recommended Minimum Navigation Information Send RMC Recom...

Page 41: ...e Speed 1 VTG Course and speed over ground 2 RMC Recommended minimum specific GNSS data 3 OSD Own ship data 4 AIVDO AIS own ship position UAIS VHF Data link own vessel report Heading 1 THS True headin...

Page 42: ...ht you enter the largest possible height and draught taking load conditions into consideration When a second TECDIS unit is present in the installation for example backup unit The IP address of the se...

Page 43: ...Mode is active Alarm if HDT1 HDT2 2 5 When this box is checked an alarm will be given if the heading from the two sensors Heading 1 and Heading 2 deviates with more than 2 5 degrees If two positioning...

Page 44: ...selecting correct IP address 192 168 0 113 port 2003 Setup procedure 1 Select appropriate comport with desired data 2 Select appropriate baud rate on receiving comport by using Speed dialog box 3 Sele...

Page 45: ...select the CD ROM drive from the drop down menu below the database list The Setup program will read the CD and display the available actions for the chart database Install Update Remove and Set as De...

Page 46: ...ase you select from the list of installed databases Remove and Set as Default We recommend that the World database should be set as default if installed Important Some chart databases are protected an...

Page 47: ...rive and a message informing you about the file name and location of the file Send this file to the specified email address whenever the Vessel information data is changed 3 5 4 Start C Map Chart Mana...

Page 48: ...ration file loaded does not match the connected monitor Obtain the correct calibration file from your TECDIS support provider and repeat manual calibration Monitor contains wrong automatic calibration...

Page 49: ...cense is shown as illustrated below This information includes the license number and version information and a list of installed optional components in blue in the right part of the area In order to a...

Page 50: ...if you want to use a supplied password usr file to activate chart licenses browse to the location of this file and select it and press OK The licenses contained in the file will be automatically activ...

Page 51: ...a specify the conditions needed before Track Control mode can be activated Max course deviation The maximum number of degrees the course over ground COG of the vessel can differ from the planned cours...

Page 52: ...ld be determined during vessel sea trials Max allowed WOL distance x 0 01 NM This setting specifies the maximum value allowed for operator selected Wheelover Line WOL distance expressed as hundredths...

Page 53: ...unique license dongles Telko eToken ID numbers must be different NOTE The automatic method is activated by default in all TECDIS units produced after 1 November 2008 3 8 1 Basic Method When the basic...

Page 54: ...ress Execute 6 On the TECDIS unit where all routes should be removed select Delete ALL routes on this TECDIS and activate replication and press Execute 7 On both TECDIS units remove the service dongle...

Page 55: ...Select the desired folder by pressing a folder title 4 1 Setup This folders contains 1 Ship draught 2 Language selection 3 Time zone selection 4 Nmea input status 5 Nav Position offset 6 Chart utiliti...

Page 56: ...meters for the Ship 4 2 1 Own ship offcenter Location of own ship on the screen High value Vessel is placed more offcenter Low value vessel is placed closer to screen centre This function is only acti...

Page 57: ...ay filter Relative COG vectors Allows display of COG vectors relative to own ship movement Vectors are true if this option is not selected 4 3 5 Lost active targets AIS targets inside the specified ra...

Page 58: ...chart in the list it will appear if license is present When vessel is sailing vessel is automatically centered if not auto function is disabled NB Chart library only displays databases selected in set...

Page 59: ...ld as ENC cells in S57 format Trough import to a database every ENC cell is converted to a dataset This is a two step process verification of data and conversion compilation to a dataset To import dat...

Page 60: ...disable error report it is impossible to view detailed information about the data import Also errors reasoning ENC cells not to be imported due to critical errors are not displayed A import log will...

Page 61: ...asing old data 17 Could not create data file Hard drive error or full try erasing old data 18 Tried to create existing index file System error should not normally occur 19 Tried to create existing dat...

Page 62: ...mmunication with license dongle 195 Cmap registry error Error in communication with license dongle 196 Dongle is not Telko dongle License dongle not approved 197 No eToken dongle present No license do...

Page 63: ...rly visible Check colors Open test diagram T All diagonal lines to clearly separate from background 3 Yellow diagonal lines 4 orange diagonal lines 3 magenta diagonal lines 4 green diagonal lines 3 bl...

Page 64: ...TECDIS Installation Manual Page 63 This page is intentionally left blank...

Page 65: ...s working properly 8 Check that TECDIS transmits alarm to external systems 9 If installed verify generation of conning picture and correct display of sensor data on conning monitor check against engin...

Page 66: ...Up 29 Alarm loudspeaker 30 MOXA interface 31 AUTOPILOT 32 Additional units 33 Additional units Item Software Version Comments 34 TECDIS Main 35 TECDIS Back up 36 AUTOPILOT 37 Additional software 38 A...

Page 67: ...TECDIS 1 Good NG N A TECDIS 2 Good NG N A 4 System status Check that no alarms warnings are pending in alarm window TECDIS 1 Good NG N A TECDIS 2 Good NG N A 5 Chart database 1 Select setup menu char...

Page 68: ...sensors and observe dead reckoning performance verify that alarm is given pos sensor lost 2 Activate track dialog and set past tracks visible by clicking on show icon 3 Enter manual fix by activating...

Page 69: ...manual mode by switching steering mode selector Verify that change to manual mode is possible from all modes with a single operator action Good NG N A 5 Function 1 Change set course 50 deg to starboa...

Page 70: ...ship follows the test route selected on ECDIS Recommend test speed is normal sea speed 2 Check performance according item 1 with speed reduction applied in one turn 3 Check performance according item...

Page 71: ...of route for Track Control testing WPT 3 135 deg turn port WPT 5 135 deg turn starboard both with minimum radius WPT 4 60 deg turn port WPT 7 60 deg turn starboard both with 2 NM radius Minimum radius...

Page 72: ...in turn Turn radius is with 1 0NM Ship start turn from wheel over point with 90 deg Angle Approach run Trial Speed NSR Wheel Over Point ECDIS Scheduled Track Course 90 deg TCS Test 2 Failure point at...

Page 73: ...in effect Remove Track Control connection from ECDIS while sailing straight ahead 6 Disconnect serial link to heading controller during turn Emits alarm and stops TCS function simultaneously Automatic...

Page 74: ...ne serial line display of sensor data relevant according to failed serial line on conning monitor is not affected 2 General Verify that installation is done according to block diagram for TECDIS AW sy...

Page 75: ...TECDIS Installation Manual Page 74 6 4 Installation Notes...

Page 76: ...TECDIS Installation Manual Page 75...

Page 77: ...andle mode case 53 30 03 06 Chapter 4 1 New function time zone selection case 98 22 05 06 Revision 1 5 22 10 2006 Chapter 3 2 Updated illustration Chapter 3 2 6 Added description of RCU 018 ctrl field...

Page 78: ...sor and other connection requirements for Track Control functionality and requirements to ensure freeze rudder functionality Section 6 Added checklists for Track Control system and installation notes...

Page 79: ...TECDIS Installation Manual Page 78 This page is intentionally left blank...

Page 80: ...6025 Aalesund Telephone 47 70 10 29 50 Telefax 47 70 10 29 51 E mail furuno furuno no Web www furuno no Branch office Deep Sea Furuno Norge AS Visitor address Shipment address vre Fyllingsvei 81 N 51...

Reviews: